ADJUSTING THE DIRECTION OF AIR CIRCULATION

Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s SET button. Horizontal (right-left)
airflow direction is adjusted manually, by moving the Air Flow Direction Louvers.
Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction
louvers are stopped.

 

R

 

DANGER!

Never place fingers or foreign objects in-
side the outlet ports, since the internal fan
operates at high speed and could cause
personal injury.

Always use the remote control unit’s

SET button to adjust the vertical airflow

louvers. Attempting to move them

manually could result in improper

operation; in this case, stop operation

and restart. The louvers should begin
to operate properly again.

During Cooling and Dry modes, do not

move the vertical air direcion louvers
outside their proper operating range

for the mode (

1

 - 

3

) and into the fan

region (

4

 - 

7

) ; using the louvers in

the fan region will cause moisture to

condense near the air outlet, and water

may drop onto the floor. During the

Cooling / Dry modes, if the louvers are

operated outside the range 

1

 - 

3

 for

more than 30 minutes, they will

automatically return to position 

3

range.

When used in a room with infants, chil-

dren, elderly or sick persons, the air

direction and room temperature

should be considered carefully when

making settings.

Vertical Air Direction Adjustment

Press the SET button (Fig. 6 

O

).

Each time the button is pressed, the air direction range will change as follows:

1

 

 

2

 

 

3

 

 

4

 

 

5

 

 

6

 

 

7

Types of Air flow Direction Setting:

1

,

2

,

3

: During Cooling / Dry modes

4

,

5

,

6

,

7

: During Heating mode

1

,

2

,

3

,

4

,

5

,

6

,

7

: During Fan mode

The remote Control Unit’s display does
not change.

Use the air direction adjustments within the ranges shown above.

The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.

During Cooling / Dry / Fan mode

:

Horizontal flow 

1

During Heating mode

:

Downward flow 

7

During AUTO mode operation, for the first minute after beginning operation,
airflow will be horizontal 

1

; the air direction cannot be adjusted during this period.

Right-Left Adjustment

Adjust the Right-Left louvers.

Move the Right-Left louvers to adjust air flow in the direction you prefer.

knob

R

 

DANGER!

When adjusting the Right-Left Louvers, it
is necessary to stop the Air-Conditioner
first and make sure that it stops completely
before adjusting the direction.

knobs (three places)

Summary of Contents for Inverter Halcyon AOU12R2

Page 1: ...or Unit ASU9R2 ASU12R2 Outdoor Unit AOU9R2 AOU12R2 KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO HEAT COOL MODEL REVERSE CYCLE ROOM AIR CONDITIONER WALL MOUNTED TYPE ...

Page 2: ... drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any electronic equipment is at least one metre away from either the in door or outdo...

Page 3: ...op the test operation mode press the START STOP button to stop the air conditioner T Remote Control Unit Display Fig 8 U Transmit Indicator V Clock Display W Operating Mode Display X Timer Mode Display Y Fan Speed Display Z Temperature Set Display Timer Set Indicator Temperature Set Indicator Refer to the folded out page on the cover Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO ...

Page 4: ... period of operation When the set time is reached the unit automatically turns off SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room WIRELESS REMOTE CONTROL UNIT The Wireless Remote Control Unit allows convenient con trol of air conditioner operation MILDEW RESISTANT FILTER The AIR FILTER has been treated to...

Page 5: ... the re verse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Fig 6 R Use the tip of a ball point pen or other small object to press the button 2 Use the SET TEMP SET TIME buttons Fig 6 I to adjust the clock to the ...

Page 6: ...n Speed Press the FAN CONTROL button Fig 6 L Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the tempera ture of the air issued from the indoor unit is low Co...

Page 7: ...utes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operatio...

Page 8: ... single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the arrow in the Remote Control Unit s Display OFF ON or OFF ON One example of Program timer use might be to have the air conditio...

Page 9: ...s elapsed at which time the air conditioner automatically turns off SLEEP timer setting 4 F 6 F 8 F 30 minutes 2 F 1 hour 1 hour 30 minutes Set time Set time 1 hour 2 F 4 F Unlike other timer functions the SLEEP timer is used to set the length of time until air conditioner operate is stopped To Use the SLEEP Timer While the air conditioner is operating or stopped press the SLEEP button Fig 6 N The...

Page 10: ...ed outside the range 1 3 for more than 30 minutes they will automatically return to position 3 range When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Fig 6 O Each time the button is pressed the air direction range will change as follows...

Page 11: ... very low speeds MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 on the main unit control panel To stop operation press the MANUAL AUTO button once again Controls are located inside the Intake Grille When the air conditioner is operated with the controls ...

Page 12: ... unit be inspected regularly in addition to your own cleaning and care For more information consult authorized service personnel When cleaning the unit s body do not use water hotter than 108 F harsh abrasive cleansers or volatile agents like benzene or thinner Do not expose the unit body to liquid insecticides or hairsprays When shutting down the unit for one month or more first allow the fan mod...

Page 13: ...oner resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will st...

Page 14: ...ith a Microcomputer controlled Auto matic Defrosting function If frost forms the air condi tioner will temporarily stop and the defrosting circuit will operate briefly for about 7 15 minutes During Automatic Defrosting operation the OPERATION indicator lamp red will flash Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring t...

Page 15: ...5 F 88 F or less Temperature and Humidity Range If the unit is used for long pe riods under high humidity conditions condensation may form on the surface of the in door unit and drip onto the floor or other objects underneath About 80 or less About 50 or less Indoor Humidity Outdoor temperature 68 F or obove Outdoor temperature below 68 F ...

Page 16: ......

Page 17: ......

Page 18: ......

Reviews: