11

Vertical Air Direction Adjustment

Press the SET button (Fig. 5 

K

).

Each time the button is pressed, the air direction range will change as follows:

 1 

 2 

 3 

 4 

 5 

 6 

Types of Air ow Direction Setting:

1, 2, 3 : During Cooling/Dry modes
1, 2, 3, 4, 5, 6 : During Fan mode

The Remote Controller's display does not change.

  Use the air direction adjustments within the ranges shown above.

 The vertical air ow direction is set automatically as shown, in accordance with the 

type of operation selected.

 

During Cooling/Dry mode : Horizontal  ow 1

  During AUTO mode operation, for the  rst a few minutes after beginning operation, 

air ow will be horizontal 1; the air direction cannot be adjusted during this period.

Right-Left Adjustment

Adjust the Right-Left louvers.

Move the Right-Left louvers to adjust air ow in the direction you prefer.

ADJUSTING THE DIRECTION OF AIR CIRCULATION

Vertical (up-down) direction of air ow is adjusted by pressing the Remote Controller's SET button. Horizontal (right-left) air ow direc-
tion is adjusted manually, by moving the Air ow Direction Louvers.
Whenever making horizontal air ow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are 
stopped.

 

DANGER

Never place  ngers or foreign objects inside 
the outlet ports, since the internal fan operates 
at high speed, and personal injury could be 
caused.

  Always use the Remote Controller's 

SET button to adjust the vertical air ow 
l o u v e r s . A t t e m p t i n g  t o  m o v e  t h e m 
m a n u a l l y  c o u l d  r e s u l t  i n  i m p r o p e r 
operation; in this case, stop operation 
and restart. The louvers should begin to 
operate properly again.

  During use of the Cooling and Dry 

modes, do not set the Air ow Direction 
Louvers in range (4–6) for many hours, 
since water vapor may condense near 
the outlet louvers and drops of water 
may drip from the indoor unit. During the 
Cooling and Dry modes, if the Air ow 
Direction Louvers are left in range 4–6 
for more than 30 minutes, they will 
automatically return to position 3.

  When used in a room with infants, 

children, elderly or sick persons, the 
air ow direction and room temperature 
should be considered carefully when 
making settings.

 

CAUTION

When adjusting the Right-Left Louvers, it 
is necessary to stop the Vertical (up-down) 
louvers first and make sure that it stops 
completely before adjusting the direction.

1

2

3

4
5

6

Knob (2 places) 

Right-Left Louvers

Knob

9332428018_OM_EN.indd   11

9/20/2011   9:39:10 AM

Summary of Contents for Inverter 9332428032

Page 1: ...OM AIR CONDITIONER COMPACT WALL MOUNTED TYPE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this product ...

Page 2: ...ed In the event of a malfunction burning smell etc immediately stop operation turn off the breaker and consult authorized service personnel In the event of refrigerant leakage be sure to keep away from re or any ammables consult an autho rized service personnel Provide occasional ventilation during use Do not direct air ow at replaces or heating apparatus Do not climb on or place objects on the ai...

Page 3: ...mildew growth thus al lowing cleaner use and easier care POLYPHENOL CATECHIN AIR CLEANING FILTER The Polyphenol Catechin Air Cleaning lter uses static elec tricity to clean ne particles and dust in the air such as tobacco smoke and plant pollen that are too small to see The filter contains catechin which is highly effective against various bacteria by suppressing the growth of the bacteria adsorbe...

Page 4: ...facilitate explanation the accompanying illustra tion has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current operation Fig 6 Fig 2 Fig 3 Fig 4 ...

Page 5: ...A Air ow Direction Louver B Right Left Louver behind Air ow Direction Louver C Drain Hose Fig 5 Remote Controller D Signal Transmitter E MODE button F ECONOMY button G SLEEP button H TIMER MODE button I FAN button J START STOP button K SET button Vertical L SWING button M SET TEMP button N TIMER SET button O CLOCK ADJUST button P TEST RUN button This button is used when installing the air conditio...

Page 6: ... arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 5 O Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 5 N to adjust the clock to the current time button Press to advance the time button Press to reve...

Page 7: ...e thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN button Fig 5 I Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Cooling As the room temperature approaches that of the thermo...

Page 8: ...temperature setting If the mode automatically selected by the unit is not what you wish select one of the mode operation COOL DRY FAN About Mode Operation Cooling Use to cool your room Dry Use for gently cooling while dehumidifying your room During Dry mode the indoor unit will operate at low speed in order to ad just room humidity the indoor unit s fan may stop from time to time Also the fan may ...

Page 9: ...ater the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve 1 transition from OFF timer to ON timer or from ON timer to OFF timer within a 24 hour period The rst timer function to operate will be the 1 set nearest to the current time The order of operation is indicated by the...

Page 10: ...e About 5 seconds later the entire display will reappear To Cancel the Timer Use the TIMER MODE button to select CAN CEL The air conditioner will return to normal opera tion To Stop the Air Conditioner During Timer Operation Press the START STOP button About the SLEEP Timer To prevent excessive cooling during sleep the SLEEP timer function automatically modi es the thermostat setting in accordance...

Page 11: ...al air ow adjustments start air conditioner operation and be sure that the vertical air direction louvers are stopped DANGER Never place ngers or foreign objects inside the outlet ports since the internal fan operates at high speed and personal injury could be caused Always use the Remote Controller s SET button to adjust the vertical air ow louvers Attempting to move them manually could result in...

Page 12: ...ssing the ECONOMY operation button When ECONOMY operation mode is operated the room temperature will be little higher than the set temp under cooling mode Therefore the ECONOMY mode is able to save more energy than other normal mode SWING OPERATION Begin air conditioner operation before performing this procedure To select SWING Operation Press the SWING button Fig 5 L The SWING Display Fig 6 X wil...

Page 13: ...ur face and drip If the unit is used under higher temperature conditions than those noted here the automatic protection circuit may operate interrupting the operation If the unit is used under lower temperature conditions than those noted here the heat exchanger may freeze causing water leakage or other malfunction Do not use the air conditioner for any purpose other than cooling or drying room or...

Page 14: ...ir lter with the panel and push in fully making sure the 2 lower tabs are returned prop erly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the indoor unit without Intake Grille installed Dust can be cleaned from the air lter either with a vacuum cleaner or by washing the lter in a solution of neutral de tergent and warm water If you wash the l...

Page 15: ... is not a one off product Please purchase delicated deodorizing lter UTR FA16 2 sold separately when exchanging the lter Maintenance of Deodorizing Filters In order to maintain the deodorizing effect please clean the lter in the follow way once 3 months 1 Remove the deodorizing lter 2 Clean with water and dry in the air a Flush the lter with high pressure hot water until the surface of the filter ...

Page 16: ...rom the sudden Cooling of room air by the cool air emitted from the indoor unit resulting in con densation and misting Air ow is weak or stops During Dry mode the indoor unit will operate at low speed in or der to adjust room humidity the indoor unit s fan may stop from time to time Also the fan may operate at very low speed when adjusting room humidity 8 During SUPER QUIET operation the fan will ...

Reviews: