background image

En-7

OPERATION

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

* During Heating mode:

Set the thermostat to a temperature set-
ting that is higher than the current room
temperature. The Heating mode will not
operate if the thermostat is set lower than
the actual room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature set-
ting that is lower than the current room
temperature. The Cooling and Dry modes
will not operate if the thermostat is set
higher than the actual room temperature
(in Cooling mode, the fan alone will oper-
ate).

During Fan mode:

The heat and cool functions of this unit
cannot operate at the same time.

About Mode Operation

AUTO:
COOLING MODEL

When the room temperature is 4 °F
higher than the set temperature, the
mode will switch between Cooling and
Drying.

During the Drying mode operation, the
FAN setting should be switched to LOW
for a gently cooling effect during which
the fan may temporarily stop rotating.

If the mode automatically selected by the
unit is not satisfactory, see page 6 for in-
structions on changing the mode setting
(COOL, DRY, FAN).

AUTO (* AUTO CHANGEOVER):
HEAT & COOL MODEL (Reverse cycle)

When AUTO CHANGEOVER is selected, the air conditioner selects the appropri-
ate operation mode (Cooling or Heating) according to your room’s present tem-
perature.

When AUTO CHANGEOVER is first selected, the fan will operate at very low speed
for about one minute while the unit determines the current conditions of the
room and accordingly selects the proper operation mode.

When the air conditioner has adjusted your room’s temperature to near the ther-
mostat setting, it will begin monitor operation. In the monitor operation mode,
the fan will operate at low speed. If the room temperature subsequently changes,
the air conditioner will once again select the appropriate operation (Heating, Cool-
ing) to adjust the temperature to the value set in the thermostat. (The monitor
operation range is ±4 °F relative to the thermostat setting.)

If the mode automatically selected by the unit is not satisfactory, see page 6 for
instructions on changing the mode setting (HEAT, COOL, DRY, FAN).

*Heating:

Use to warm your room.

When Heating mode is selected, the air conditioner will operate at very low fan
speed for about 3 to 5 minutes, after which it will switch to the selected fan set-
ting. This period of time is provided to allow the indoor unit to warm up before
beginning full operation.

When the room temperature is very low, frost may form on the outside unit, and
its performance may be reduced. In order to remove such frost, the unit will
automatically enter the defrost cycle from time to time. During Automatic De-
frosting operation, the OPERATION indicator lamp (red) will flash, and the heat
operation will be interrupted.

Cooling:

Use to cool your room.

Dry:

Use for gently cooling while dehumidifying your room.

You cannot heat the room during Dry mode.

During Dry mode, the unit will operate at low speed; in order to adjust room
humidity, the indoor unit’s fan may stop from time to time. Also, the fan may
operate at very low speed when detecting room humidity.

The fan speed cannot be changed manually when Dry mode has been selected.

Fan:

Use to circulate the air throughout your room.

Setting temperature

Thermostat control

Dry Operation

Cooling Operation

4 °F

9362292047_OM_en.p65

3/8/05, 19:26

7

Summary of Contents for Halcyon 9362292047

Page 1: ...AIR CONDITIONER CEILING SUSPENSION TYPE P N9362292047 English Français Español KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO ...

Page 2: ...enever cleaning the air conditioner or chang ing the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow When restarting after a long period of disuse in the winter turn the power switch on at least 12 hours before starting the unit Do not drink the water d...

Page 3: ...EAT COOL MODEL REVERSE CYCLE When the SLEEP timer button is pressed during Heating mode the air conditioner s thermostat setting is gradu ally lowered during the period of operation during Cool ing or Dry mode the thermostat setting is gradually rised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTRO...

Page 4: ... AUTO 3 4 5 6 7 2 1 9 8 0 Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle NAME OF PARTS Fig 4 Fig 5 Fig 6 Fig 1 This breaker is installed during the electrical installation Fig 3 Electrical Breaker Fig 2 ...

Page 5: ...utton J AIR FLOW DIRECTION HORIZONTAL SET button K AIR FLOW DIRECTION HORIZONTAL SWING button L TIME ADJUST button M ACL button located inside battery compartment Rear side Fig 5 N TEST RUN Touch the two metal contacts with a me tallic object to send the signal to perform a test run Perform a test run only when installing the air conditioner If the signal to perform a test run is received during n...

Page 6: ... side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the SET TIME buttons to adjust the clock to the current time button Press to advance t...

Page 7: ...ut three seconds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About three seconds later the entire display will reappear When set to AUTO Heati...

Page 8: ...air conditioner has adjusted your room s temperature to near the ther mostat setting it will begin monitor operation In the monitor operation mode the fan will operate at low speed If the room temperature subsequently changes the air conditioner will once again select the appropriate operation Heating Cool ing to adjust the temperature to the value set in the thermostat The monitor operation range...

Page 9: ...R button to select the PROGRAM timer operation either OFF ON or OFF ON will display The display will alternately show OFF timer and ON timer then change to show the time setting for the operation to occur first The PROGRAM timer will begin operation If the ON timer has been selected to operate first the unit will stop operating at this point About five seconds later the entire display will reappea...

Page 10: ...s operating or stopped press the SLEEP button Both the indoor unit s OPERATION indicator lamp red and the TIMER indicator lamp green will light To Change the Timer Settings Press the SLEEP button once again and set the time using the SET TIME buttons Set the time while the Timer Mode Display is flashing the flashing will continue for about five seconds button Press to advance the time button Press...

Page 11: ...l be horizontal 1 the air direction cannot be adjusted during this pe riod Horizontal Air Direction Adjustment Press the AIR FLOW DIRECTION HORIZONTAL SET button Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 The remote control unit s display does not change Use the air direction adjustments within the ranges shown above Fig 8 DANGER Never place fingers or...

Page 12: ...e Heating range 4 to 5 for long periods of time since water vapor may con dense near the outlet port and drops of water may drip from the air conditioner To select Horizontal airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button The SWING indicator lamp HORIZONTAL SWING orange will light In this mode the RIGHT LEFT air direction louvers will swing automatically to direct the...

Page 13: ... you wash the filter be sure to allow it to dry thoroughly in a shady place before rein stalling If dirt is allowed to accumulate on the air filter air flow will be reduced lowering operating efficiency and increas ing noise During periods of normal use the air filters should be cleaned every four weeks Cleaning the Air Filter 1 Pull the air filters upward to remove them Remove the air filters by ...

Page 14: ...ast five seconds to display the current signal code initially set to 3 Press the buttons Fig 4 C to change the signal code between Match the code on the dis play to the air conditioner signal code 4 Press the MASTER CONTROL button again to return to the clock display The signal code will be changed SELECTING THE REMOTE CONTROL UNIT SIGNAL CODE To operate only one of multiple air conditioners If no...

Page 15: ...ture changes During Heating operation a sizzling sound may be heard occa sionally This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results fr...

Page 16: ...ns relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle Operation and Performance Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we ...

Page 17: ...mer will be reset and the unit will begin or stop operating under the new timer setting In this event the TIMER indicator lamp green will flash see page 4 Use of other electrical appliances electric shaver etc or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction In this event temporarily disconnect the power supply reconnect it and then use the remote control ...