background image

 

(Continued from the front page) 

Step5 Exit the Operation

 

Step4 Access a Serial Device

 

 

NC14013-0927RS-03 

Inquiry about our products

 

FUJITSU COMPONENT LIMITED    Marketing Group 

TEL: 81-3-5449-7006 
E-mail: [email protected]       URL: http://www.fcl.fujitsu.com/en/ 

 

 

 
 
 
 
 

8.  Confirm there is a check in "Enable all ports". To change the 

default pin out when a Cisco device is connected to the 
selected port, click the "Enable Cisco RJ45 Pin-Out" checkbox. 
To reconfigure the connections settings to match the device 
connected to the selected port, make the needed changes in 
the Communication Settings area of the screen. And then click. 

4.  The ”Password:” prompt is displayed. Enter the current login 

user password (in this case: admin). 

Log out the OBWI after finishing the operation. 

Perform an operation on a connected serial device. 

1.  Click [LOGOUT] in top right of the OBWI. 

1.  Select “Access” from left menu in Expert mode, the content 

area displays the name of this device and list of each port. 

 
 
 
 
 
 
 
 
 

The basic operating procedure has completed. 

5.  The following message appears, and serial device operations 

are enabled. 

 

NOTES

 

Installing Java Runtime Environment (JRE). 

You have to install Java Runtime Environment (JRE) of Sun 
Microsystems in a remote terminal to let this document Step4 
display the serial viewer screen of mention. If not yet, download 
Java software in the following web site and install it. 

http://www.java.com/en/

 Or, JRE is stored in CD-ROM, please 

use it. In addition, by the setting of the browser, it is necessary 
for JRE to become effective. 

A confirmation method of the JRE availability (IE 7) 

Click [Tools] menu 

 [Internet Options] 

 [Advanced] tab. 

Make sure that Java Sun [Use JRE 1.x.x._xx for <applet> 
(requires restart)] is checked. (x is version No.)

 

 

2.  Select ”Serial Viewer” from the ”Action” column 

 

These settings can be changed again later. 

 
 
 

9.  Save is executed, and the screen below appears. Click [finish]. 

 
 
 
 
 
 
 
 
 

6.  Click [Disconnect] in bottom of the Serial Viewer window or [x] 

in top right of the Serial Viewer window to finish the operation. 

3.  Start up a Java applet, the following Serial Viewer window is 

displayed. When the warning dialog appears, click "Run". 

 
 
 
 

10.  The First Time Configuration has completed, and Expert mode 

screen appears. 

 
 

 

 

 

 

* When a popup block becomes effective in a browser (e.g. 
Internet Explorer), Serial Viewer window is not displayed. You 
have to configure a browser to admit popup window. 

 

 

For software setup or details on operations, refer to 
the Installer/User Guide in the CD-ROM provided 
with the device.

 

 