Chapter 4 Troubleshooting
4.2 Troubleshooting Table
FUJITSU Storage ETERNUS LT40 S2/LT60 S2 LTO Library Installing, Starting Up and Maintaining
Copyright 2018 FUJITSU LIMITED
P3AM-5392-07ENZ0
73
4.2
Troubleshooting Table
Table 4.1 Troubleshooting table
Problem
Solution
Power
Library does not power on
•
Check all power cord connections.
•
Make sure the power switch on the front panel is in
the ON position.
•
Make sure there is power to the outlet. Try another
working outlet.
•
Replace the power cord.
•
Contact your service representative.
No display messages appear
•
Make sure the power cord is connected.
•
Make sure the power switch is on.
•
Power cycle the library.
•
Download library firmware.
•
Contact your service representative.
Tape Movement
Tape stuck in drive
•
Power cycle the library, allow it to complete
initialization, which in rare cases can take as long as
10 minutes, and then retry unloading the tape using
the library operator control panel.
•
Allow the tape drive to complete all operations. This
may take as long as ten minutes if you reset or cycle
power on the library while the cartridge is positioned
at the physical end of the media.
•
Make sure that the backup software is not reserving
the slot or preventing the tape drive from ejecting the
cartridge. The backup software needs to cancel the
reservation and any hold it has on the tape drive.
Temporarily disconnecting the library from the host
server and power cycling eliminates the host and its
software as a problem source.
•
Contact your service representative.
Tape stuck in storage slot
See section