Chapter 5 Information Settings and Display
5.4 Utility > show pinned-data
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
680
show pinned-data
If certain failure events have occurred when writing data, data cannot be written back to the disk(s)
(volumes) from the cache data area. The data that cannot be written back to the disk is retained in the cache
data area and is called pinned data (PIN).This command displays a list of all the pinned data.
■
Syntax
■
Parameter
No parameters.
■
Output
■
Example(s)
show pinned-data
# Volume LBA RC SK ASC ASCQ
# No. Name
# 1 VolumeNumber0001 0x0000000000000000 0x00 0x00 0x00 0x00
A B C D E F G
A:
Volume number
B:
Volume name
C:
Logical block address (LBA of volume in which pinned data is retained)
D:
Reason code
E:
Sense key
F:
Additional sense code (Sense code)
G:
Additional sense code qualifier (Sub sense code)
The following example displays a list of all the pinned data:
CLI> show pinned-data
Volume LBA RC SK ASC ASCQ
No. Name
1 VolumeNumber0001 0x0000000000000000 0x00 0x00 0x00 0x00
1 VolumeNumber0001 0x0000000000000100 0x00 0x00 0x00 0x00
3 Vol3 0x0000000000000000 0x00 0x00 0x00 0x00
4 Vol4 0x0000000000000000 0x00 0x00 0x00 0x00
4 Vol4 0x0000000000001000 0x00 0x00 0x00 0x00
11 Vol11 0x0000000000000000 0x00 0x00 0x00 0x00
The following example displays the MLU volumes:
CLI> show pinned-data
Volume LBA RC SK ASC ASCQ
No. Name
- - - 0x00 0x00 0x00 0x00
Summary of Contents for Eternus DX410 S2
Page 2: ...This page is intentionally left blank ...
Page 756: ......