Additional Information
l
Before you can add a replication target, you must add the ETERNUS CS800 to the list of
allowed replication sources on the target ETERNUS CS800 (see
l
To add a new target when two targets are already configured, first delete one target (see
"Deleting a Replication Target" on page 276
). Then add the new target.
l
For more information about enabling and scheduling replication for a share or partition,
see
"Replication Send" on page 371
.
To add a replication target:
1. Under
Target System
, click
Add
.
The
Add Target Host
window displays (see
).
Figure 178: Add Target Host
2. In the
Target Hostname or IP
box, enter the hostname or IP address of the system that
will receive the replicated data.
When entering IP addresses, never use an address that is in a reserved IP address
range. To see a list of reserved IP address ranges, click the quick tip icon
[?]
located
near the IP address field.
To use hostname format, you must specify at least one DNS IP address on the
Network
page (see
).
3. In the
Encryption
drop-down box, select the type of encryption to use when sending
replication data to the target system (
None
,
128-bit
, or
256-bit
).
CAUTION!
For encryption, select
None
or
128-bit
if you are sending data to a ETERNUS
CS800 running a system software version prior to ETERNUS CS800 2.1.1
Software.
AES encryption options are available only if the Data-in-Flight license is
installed.
4. In the
Source IP
box, enter the IP address that is used to uniquely identify the source
ETERNUS CS800
273
10 Configuration
Summary of Contents for ETERNUS CS800
Page 1: ...ETERNUS CS800 V3 2 User Guide English ...
Page 2: ......
Page 3: ...English ETERNUS CS800 User Guide V3 2 Edition October 2015 ...
Page 26: ...26 ...
Page 42: ...42 ...
Page 78: ...78 ...
Page 132: ...6 3 Running the Getting Started Wizard Figure 91 Confirm Page 132 ETERNUS CS800 ...
Page 143: ...Figure 97 Remote Management Pages Map ETERNUS CS800 143 7 Remote Management ...
Page 144: ...144 ...
Page 184: ...8 7 AIS Connect Figure 128 AISConnect Wizard Confirm 184 ETERNUS CS800 ...
Page 198: ...198 ...
Page 321: ...Figure 206 Network Configuration ETERNUS CS800 321 10 Configuration ...
Page 335: ...Figure 215 Date Time Page To set the system date and time ETERNUS CS800 335 10 Configuration ...
Page 339: ...Figure 216 Access Control Settings Page ETERNUS CS800 339 10 Configuration ...
Page 362: ...362 ...
Page 432: ...432 ...
Page 476: ...476 ...
Page 494: ...494 ...
Page 600: ...600 ...