Chapter 6 RAID Group Status
6.3 Eco-mode Schedule (RAID Group)
ETERNUS Web GUI User’s Guide (Operation)
Copyright 2016 FUJITSU LIMITED
P2X0-1260-19ENZ0
314
-
Standard / WSV
A RAID group that is used for creating the following volumes:
•
"WSV" and "Standard"
•
"WSV" and "SDV"
•
"WSV" and "SDPV"
-
WSV
A RAID group that is used for creating "WSV" type volumes
•
RAID Level
The RAID level is displayed.
-
High Performance (RAID1+0)
-
High Capacity (RAID5)
-
High Reliability (RAID6)
-
High Reliability (RAID6-FR)
-
Reliability (RAID5+0)
-
Mirroring (RAID1)
-
Striping (RAID0)
•
Total Capacity
The total capacity of the RAID groups is displayed.
•
Eco-mode Schedule
The Eco-mode schedule name that is assigned to the RAID group is displayed. If the Eco-mode is controlled
with Storage Foundation Software ETERNUS SF, "External" is displayed. When no Eco-mode schedule has
been assigned, the field is blank.
•
Eco-mode Action
The Eco-mode schedule action status is displayed.
When no Eco-mode schedule has been assigned, a "-" (hyphen) is displayed.
-
Drive power off
The power for the drive is turned off during Eco-mode operation.
-
Drive motor off
The drive motor is stopped during Eco-mode operation.
-
Drive always on
Disable Eco-mode and the drive is always active.
•
Motor Status
The drive motor status is displayed.
-
Active
The drive motors are activated.
-
In the Boot Process
The drive motors are starting up.
-
Idle
The drive motors are stopped.
-
In the Stop Process
The drive motors are being stopped.
-
Power off
The drive power is being turned off.
Summary of Contents for ETERNUS AF250
Page 2: ...This page is intentionally left blank ...
Page 423: ......