background image

16

Technical Manual

 

D2530 (Econel 200 S2)

PCI bus

Features

3.3

PCI bus

Figure 3: PCI slots

PCI slots

The following table shows an overview of the PCI slots:

PCI IRQ Line x - Assignment of the PCI interrupts

PCI IRQ Line x defines which ISA interrupts are used for the separate PCI slots.

If you select 

Auto

 in the BIOS setup, the interrupts are assigned automatically 

and no further settings are required.

Multifunctional PCI boards or boards with an integrated PCI-to-PCI bridge can 
use several PCI interrupts (INTA#, INTB#, INTC#, INTD#). Monofunctional PCI 
boards (default) only use one PCI interrupt (INTA#) per PCI slot.

PCI slot

64Bit/

32Bit

Frequency 

in MHz

Description

1

133/100

PCI-X bus slot, IOOP

2

133/100

PCI-X bus slot, IOOP

3

133/100

PCI-X bus slot, IOOP

4

32 Bit

33

PCI bus slot

5

PCI-Express x8 slot (x4 accessed)

6

PCI-Express x16 slot (x8 accessed)

slot 6

slot 5

slot 4

slot 3

slot 2

PCI-X 133/100 MHz

PCI-Express x16

PCI-Express x8

PCI 33MHz

PCI-X 133/100 MHz

PCI-X 133/100 MHz

slot 1

Summary of Contents for D2530

Page 1: ...conel 200 S2 Technical Manual Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e mail email manuals fujitsu siemens com Tel 089 61001 155 Fax 49 700 372 00000 D2530 Econel 200 S2 Sprachen En Edition November 2006 ...

Page 2: ...according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2006 Fujitsu Siemens Computers Gmb...

Page 3: ...afety 7 2 2 CE Certificate 10 2 3 Environmental Protection 11 3 Features 13 3 1 Overview 13 3 2 Main memory 15 3 3 PCI bus 16 3 4 Screen resolution 18 3 5 Temperature system monitoring 18 3 6 Connectors and jumpers 20 3 6 1 External connectors 22 4 Replacing the lithium battery 25 Abbreviations 27 ...

Page 4: ......

Page 5: ...rams fixed font indicate system output on the monitor semi bold fixed font indicates values to be entered through the keyboard Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A If two keys need to be pressed at the same time then this is shown by placing a hyphen between the two ...

Page 6: ......

Page 7: ...f Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original packagin...

Page 8: ... As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm lightning hazard Batteries V CAUTION Incorrect replacement of lithium battery may lead to a risk of explosio...

Page 9: ... touching a grounded object before working The equipment and tools you use must be free of static charges Remove the power plug from the power socket before inserting or removing boards containing ESDs Always hold boards with ESDs by their edges Never touch pins or conductors on boards fitted with ESDs Use a grounding cable designed for this purpose to connect yourself to the system unit as you in...

Page 10: ...re when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use shar...

Page 11: ...d and should be switched off during long breaks and on completion of work Notes on packaging Please do not throw away the packaging We recommend that you do not throw away the original packaging in case you need it later for transporting Notes on dealing with consumables Please dispose batteries in accordance with local government regulations Do not throw batteries and accumulators into the househ...

Page 12: ...r D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 The device may not be disposed of with household rubbish This appliance is labelled in accordance with European Directive 2002 96 EC concerning used electrical and electronic appliances waste electrical and electronic equipment WEEE The guideline determines the framework for the return and recycling of used appliances as applicable throug...

Page 13: ...M memory modules with 512 MB 1Gbyte and 2Gbyte maximum 8 Gbyte of memory minimum 512 MB ECC multiple bit error detection and single bit error correction memory scrubbing function Single Device Data Correction SDDC function Chipkill Chipsets on the system board Intel 5000V chipset Memory Controller Hub MCH Intel 6321 I O Controller Hub ICH with integrated GBit LAN Intel Single 1 GB PHY 82564EB onbo...

Page 14: ...wer connector 12V 12V 5V 3 3V and 5V auxiliary 12V CPU power connector 2 CPU fans 1 rear fan BPSMB connector BPSMB connector RAID key External connectors 1 serial port COM1 2 PS 2 interfaces for keyboard and mouse 2 USB 2 0 ports with 480 Mbits s rear 1 VGA port 1 RJ45 LAN port PCI slots 3 x PCI X 133 100 MHz 1 x PCI 33 MHz 1 x PCI Express x16 slot x8 wired 1 x PCI Express x8 slot x4 wired BIOS fe...

Page 15: ... the descriptions how to install memory modules in the Options Guide of your server Module population Figure 2 Main memory If the memory modules are populated in pairs each pair must consist of identical memory modules 2 way interleaved mode The module capacity between pairs can differ pair 2A 2B can be populated with two 512 Mbyte modules and pair 1A 1B with two 1 Gbyte modules Following table sh...

Page 16: ...re required Multifunctional PCI boards or boards with an integrated PCI to PCI bridge can use several PCI interrupts INTA INTB INTC INTD Monofunctional PCI boards default only use one PCI interrupt INTA per PCI slot PCI slot 64Bit 32Bit Frequency in MHz Description 1 133 100 PCI X bus slot IOOP 2 133 100 PCI X bus slot IOOP 3 133 100 PCI X bus slot IOOP 4 32 Bit 33 PCI bus slot 5 PCI Express x8 sl...

Page 17: ...th the Plug Play guidelines Disabled No ISA interrupt is assigned to the PCI interrupt 3 4 5 6 7 9 10 11 12 14 15 The selected ISA interrupt is assigned to the PCI interrupt You may not select an ISA interrupt that is used by a component on the system board e g controller or an ISA board Device Bus IDsel INTA INTB INTC INTD Slot 1 PCI X 19 PXIRQ8 PXIRQ9 PXIRQ10 PXIRQ11 Slot 2 PCI X 18 PXIRQ4 PXIRQ...

Page 18: ... overheating In addition any unnecessary noise is also prevented by reducing the fan speed and information is provided about the system status The temperature and system monitoring is controlled by an onboard controller The following functions are supported Temperature monitoring Measurement of the processor temperature measurement of the ambient temperature by a temperature sensor on the LED boar...

Page 19: ...are Voltage monitoring The most important voltages are monitored When a voltage exceeds warning level high or falls below warning level low an alert will be generated Adequate measurements can be done by running agents Cover monitoring Unauthorised opening of the cover is detected even when the system is switched off However this will only be indicated when the system is switched on again System E...

Page 20: ...PW 1 2 jumper 16 USB 3 4 3 power supply ATX 17 BPSMB 4 PC98 18 floppy disk 5 power supply12V CPU1 CPU2 19 BIOSREC jumper 6 CPU1 fan 20 COM2 3 CPU 1 CPU 2 7 27 14 1 2 4 5 6 DIMM 2B DIMM 1B DIMM 2A DIMM 1A 9 SATA1 SATA3 SATA5 SATA2 SATA4 SATA6 8 Battery 11 12 15 16 17 18 19 21 20 22 23 26 24 25 PCI X 133 100 MHz PCI E x16 PCI E x8 PCI 33MHz PCI X 133 100 MHz PCI X 133 100 MHz RAID key 13 10 A ...

Page 21: ...umper 11 IDE primary 25 LAN_BW jumper 12 HDLED 26 rear fan 13 intrusion 27 external connectors 14 front panel A 5V Standby LED 1 2 PS 2 keyboard mouse powered by 5V default 2 3 PS 2 keyboard mouse powered by 5V Standby 1 2 USB device powered by 5V default 2 3 USB device powered by 5V Standby 1 2 system BIOS default 2 3 recover system BIOS Flash BIOS Recovery Diskette required 1 2 onboard VGA enabl...

Page 22: ... D2530 1 2 onboard LAN enabled default 2 3 onboard LAN disabled PCI LAN controller 1 2 LAN bandwidth setting to balanced mode default 2 3 LAN bandwidth setting to centric mode lightning green standby power present off AC loss or system board not connected to power supply unit 1 PS 2 mouse port 4 Serial port COM1 2 PS 2 keyboard port 5 VGA port 3 USB port 1 2 6 LAN port 3 5 6 2 1 4 ...

Page 23: ... the transfer rates of 10 Mbit s 100 Mbit s and 1 Gbit s and supports WOL function through Magic Packet It is also possible to boot a device without its own boot hard disk via LAN Here Intel PXE is supported The LAN controller connector is equipped with two LEDs light emitting diode indicating the transfer rate and the activity Figure 6 LAN connector 1 LAN link activity green on LAN connection off...

Page 24: ......

Page 25: ...laced with an identical battery or a battery type recommended by the manufacturer CR2032 Do not throw lithium batteries into the trashcan It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Figure 7 Replacing the lithium battery Ê Press the locking spring into direction of of...

Page 26: ......

Page 27: ...ed here are valid for the described system board AC Alternating Current ACPI Advanced Configuration and Power management Interface ANSI American National Standards Institute ASR R Automatic Server Recovery and Restart ATA Advanced Technology Attachment BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM COMmuni...

Page 28: ...m Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EFI Extensible Firmware Interface EGB Elektrostatisch gefährdete Bauteile EHCI Enhanced Host Controller Interface EMI Electromagnetic interference EMRL Embedded RAID Logic EMV Elektromagnetische Verträglichkeit electromagnetic compatibility EPROM Erasable Programmable Read Only Memory ...

Page 29: ...troller FRU Field Replaceable Unit FSB Front Side Bus ICE In Circuit Emulation IDE Integrated intelligent Drive Electronics IEC International Electrotechnical Commission IME Integrated Mirroring Enhanced IOOP Intelligent Organisation Of PCI IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface iRMC integrated Remote Management Controller ...

Page 30: ... Diode MPS Multi Processor Specification NMI Non Maskable Interrupt OEM Original Equipment Manufacturer OHCI Open Host Controller Interface OS Operating System PCI Peripheral Components Interconnect PDA Prefailure Detection and Analyzing PIO Programmed Input Output PDB Power Distribution Board PLD Programmable Logic Device PS U Power Supply Unit ...

Page 31: ...ction of the Use of Certain Hazardous Substances Waste from Electric and Electronic Equipment EU Directive RoMB RAID on Motherboard RSB Remote Service Board RST ReSeT RTC Real Time Clock SAS Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interface SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SEL System Event Log ...

Page 32: ... SMM Server Management Mode SMP Symmetrical Multi Processing UHCI Unified Host Controller Interface USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module WEEE Waste from Electric and Electronic Equipment EU Directive WfM Wired for Management WOL Wake up On LAN ...

Page 33: ...onel 200 S2 D2530 Econel 200 S2 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 81730 München Germany Fax 49 700 372 00000 e mail manuals fujitsu siemens com http manuals fujitsu siemens com ...

Page 34: ......

Page 35: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...

Reviews: