ERROR CONTENTS
Error
Operation
LED
Timer LED
Serial signal error
Off
2 flash
3 flash
4 flash
5 flash
Serial signal (reverse) error, at operation start up
Serial signal (reverse) error, during operation
Serial signal (forward) error, at operation start up
Serial signal (forward) error, during operation
Indoor unit thermistor error
2 flash
2 flash
Outdoor unit thermistor error
3 flash
3 flash
2 flash
3 flash
4 flash
8 flash
Indoor unit control error
4 flash
2 flash
3 flash
2 flash
4 flash
3 flash
Display
Error
Outdoor unit control error
5 flash
2 flash
3 flash
5 flash
Indoor fan motor error
6 flash
2 flash
3 flash
Abnormal lock
Abnormal rotation
CT abnormal
Outdoor unit fan drive system abnormal
2 flash
Refrigerant cycle error
7 flash
3 flash
5 flash
Optional function error
Model error
8 flash
Blinking
Blinking
6 flash
Current trip error
Main relay welded
Outdoor temperature thermistor open / short
Compressor temperature abnormal
Indoor temperature thermistor open / short
Heat exchanger thermistor open
Heat exchanger middle thermistor open / short
Discharge thermistor open / short
Active filter abnormal (first time)
Active filter abnormal (second time)
Forced automatic SW welded
Power interruption error
Compressor location detection error
Model error
Discharge Temperature abnormal
Cooling high pressure abnormal rise
High pressure abnormal
2006.10.18
15
Summary of Contents for AWYZ24LBC
Page 3: ... Unit mm DIMENSIONS INDOOR UNIT 2006 10 20 2 300 298 899 250 170 40 ...
Page 17: ...2 5 61 1 1 DISASSEMBLY ILLUSTRATION INDOOR UNIT 3 7 4 2006 10 20 16 ...
Page 19: ...31 55 33 60 32 30 35 52 44 51 43 47 50 49 48 54 53 62 62 2006 10 20 18 INDOOR UNIT ...
Page 20: ...OUTDOOR UNIT 2006 10 18 19 6 11 7 5 2 4 3 1 ...
Page 21: ...9 8 10 13 15 OUTDOOR UNIT 2006 10 18 20 ...
Page 22: ...24 21 27 25 12 28 17 18 26 20 19 29 23 22 26 OUTDOOR UNIT 2006 10 18 21 ...
Page 27: ...0610G3168 ...