4. Service parts information
4-1. Compressor
Diagnosis method of compressor (If outdoor unit LED displays error, refer to troubleshooting)
Does not start up
Stops soon after starting up
Abnormal noise
↓
↓
↓
Is there open or loose con-
nection cable?
Is there open or loose con-
nection cable?
Check if vibration noise by
loose bolt or contact noise of
piping is happening.
↓
↓
↓
Check main PCB, connection
of compressor, and winding
resistance.
(Refer to the next page)
→ If there is no failure, the
defect of compressor is con-
sidered (Locked compressor
due to clogged dirt or less oil)
Is gas pipe valve open?
(Low pressure is too low)
Defective compressor can be
considered.
(due to inside dirt clogging or
broken component)
↓
↓
↓
Replace compressor.
Check if refrigerant is
leaking.
MPa
MPa
Replace compressor.
↓
↓
↓
End
Check if strainer is clogged.
(Refer to outdoor EEV or
capillary tube in this chap-
ter.)
End
↓
Check main PCB, connection of compressor and winding resis-
tance. (Refer to the next page)
→ If there is no failure, the defect of compressor can be consid-
ered. (Compression part broken or valve defective.)
↓
Replace compressor.
↓
End
4-1. Compressor
- (03-57) -
4. Service parts information
TROUBLESHOOTING
TROUBLESHOOTING
Summary of Contents for AUXG18KVLA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 05 19 SR_CH01_SM001EG_02 ...
Page 22: ...3 4 Outdoor unit 01 16 3 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 23: ...2 TECHNICAL DATA AND PARTS LIST 2021 06 15 SR_CH02_SM001EG_04 ...
Page 69: ...3 TROUBLESHOOTING 2021 06 15 SR_CH03_SM001EG_03 ...
Page 72: ......
Page 143: ...4 CONTROL AND FUNCTIONS 2021 05 19 SR_CH04_SM001EG_02 ...
Page 146: ......
Page 185: ...5 FILED WORKING 2021 06 15 SR_CH05_SM001EG_03 ...