background image

En-2

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote control unit is 
lost or otherwise unavailable.

 CAUTION

Do not press the MANUAL AUTO button with wet hands or pointed ob-
jects, otherwise an electric shock or malfunction may occur.

Starting Operation

Press the MANUAL AUTO button on the operating 
control panel.

The operation can be set in the following setting.

Operating mode

AUTO:
When Auto mode cannot be selected, it will 
operate in the same mode as the other indoor 
unit in the same system. (When other indoor 
unit in the same system doesn’t operate, the air 
conditioner will operate in cooling.)

Fan speed

AUTO

Setting temperature

23 °C

Stopping Operation

Press the MANUAL AUTO button on the operating 
control panel.

ADJUSTING THE DIRECTION OF 
AIR CIRCULATION

The vertical wind direction can be controlled with the control unit.

Vertical direction

Cooling & Dry : (1), (2), (3), (4)
Heating : 

(1), (2), (3), (4)

(1)

(2)

(3)

(4)

OPERATING TIPS

Operation and Performance

About priority state and standby state

 

Multiple indoor units can be connected within the same system. De-
pending on the system, choice of operating mode are limited.

Cooling priority state:

When the other indoor units within the same system operate in cooling 
or dry mode, heating cannot be selected at the same time.

Heating priority state:

When the other indoor units within the same system operate in heating 
mode, cooling and dry mode cannot be selected at the same time.

Standby state:

The standby state activates when 2 or more indoor units start up at the 
same time in different mode. Any indoor unit other than priority mode 
will wait in standby state until priority mode changes (operation starts 
as soon as priority is switched).
At this time, the OPERATION indicator lamp (green) lights up and the 
TIMER indicator lamp (orange) 

fl

 ashes.

Low ambient cooling

 

When the outdoor temperature drops, the outdoor unit’s fans may 
switch to Low Speed, or one of the fans may stop intermittently.

Heating performance

 

Heating mode operates on the heat-pump principle, absorbing heat 
from outdoor air and transferring that heat indoors. As a result, the 
operating performance is reduced as outdoor air temperature drops. 
If you feel that insuf

fi

 cient heating performance is being produced, we 

recommend you use this air conditioner in conjunction with another 
type of heating appliance.

 

Heating mode heat your entire room by recirculating air throughout the 
room, with the result that some time may be required after 

fi

 rst starting 

the air conditioner until the room is heated.

Microcomputer-controlled automatic defrosting

 

When using the Heating mode under conditions of low outdoor air 
temperature high humidity, frost may form on the outdoor unit, result-
ing in reduced operating performance. In order to prevent this kind of 
reduced performance, this unit is equipped with a Microcomputer-con-
trolled automatic defrosting function. If frost forms, the air conditioner 
will temporarily stop, and the defrosting circuit will operate brie

fl

 y (for 

about 4 to 15 minutes). 
During Automatic Defrosting operation, the OPERATION indicator 
lamp (green) will 

fl

 ash.

Oil recovery operation

 

Periodically, the oil recovery operation is performed in order to return 
compressor oil to the outdoor unit. During oil recovery operation, the 
OPERATION indicator lamp (green) will 

fl

 ash (for about 10 minutes).

Temperature and humidity range

 

The temperature and humidity required for operating this product is as 
shown in the following table.

Cooling/Dry Mode

Heating Mode

Outdoor 
temperature

Please refer to the speci

fi

 cation of outdoor units.

Indoor 
temperature

18 to 32 °C DB

10 to 30 °C DB

Indoor humidity

About 80% or less

 

If the air conditioner is operated under higher temperature conditions 
than those listed, the built-in protection circuit may operate to prevent 
internal circuit damage. Also, during Cooling and Dry modes, if the unit 
is used under conditions of lower temperature than those listed above, 
the heat-exchanger may freeze, leading to water leakage and other 
damage.

 

If the unit is used for long periods under high-humidity conditions, 
condensation may form on the surface of the indoor unit, and drip onto 
the 

fl

 oor or other objects underneath.

 

Do not use this unit for any purposes other than the Cooling, Heating, 
Dehumidifying, and air-circulation of rooms in ordinary dwellings.

CLEANING AND CARE

 CAUTION

 

Before cleaning the unit, be sure to stop the unit and disconnect the 
power supply.

 

Do not stand on an unstable platform when cleaning.

 

When removing and replacing the air 

fi

 lter, be sure not to touch the 

heat exchanger, as personal injury may result.

 

Be sure the intake grille is installed securely.

 

Do not clean the inside of the unit by yourself. To clean the inside, 
always consult authorized service personnel.

 

When cleaning the unit’s body, do not use water hotter than 40 °C, 
harsh abrasive cleansers, or volatile agents like benzene or thinner.

 

Do not remove any part from the unit except for the 

fi

 lter.

 

If dirt is allowed to accumulate on the Air Filter, air

fl

 ow will be reduced, 

lowering operating ef

fi

 ciency and increasing noise.

 

AUXB 04/07/09/12/14/18/24 During periods of normal use, the air 

fi

 lter 

should be cleaned every 2 months.

 

AUXD 18/24, AUXA 18/24/30/34/36/45/54 During periods of normal 
use, the air 

fi

 lter should be cleaned every 2 months.

9369313301_OM.indb   2

9369313301_OM.indb   2

12/18/2017   11:38:00 AM

12/18/2017   11:38:00 AM

Summary of Contents for AUXA18GALH

Page 1: ...consultazione futura ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Τύπος κασέτας Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά MANUAL DE FUNCIONAMENTO UNIDADE INTERIOR Tipo cassete Guarde este manual para consulta futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ кассетного типа Сохраните данное руководство для последующего использования KULLANIM KILAVUZU İÇ ÜNİTE Kaset tipi Bu kılavuzu ileri...

Page 2: ... pressure to radiator fins Do not use inflammable gases near the air conditioner Do not touch the piping during operation Ensure that any electronic equipment is at least 1 m away from either the indoor or outdoor units This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of ex perience and knowledge unless they have been...

Page 3: ...eating mode under conditions of low outdoor air temperature high humidity frost may form on the outdoor unit result ing in reduced operating performance In order to prevent this kind of reduced performance this unit is equipped with a Microcomputer con trolled automatic defrosting function If frost forms the air conditioner will temporarily stop and the defrosting circuit will operate briefly for ...

Page 4: ...stop operation be tween 4 and 15 minutes as the Automatic Defrosting mode operates See page 2 The fan may operate at low speed during Dry operation or when the unit is monitoring the room s temperature In the monitor AUTO operation the fan will operate at low speed Flashing lamps The OPERATION indicator lamp green flashes An oil recovery operation is being performed See page 2 The OPERATION indica...

Page 5: ...ation is a window allowing bright sunlight to enter Close the curtains In the case of Cooling operation are there heating apparatus and com puters inside the room or are there too many people in the room Is the fan speed set to low Set the temperature lower than the room temperature and use it Temperature does not fall down well Temperature may not fall down depending on the room conditions While ...

Page 6: ...9369313301_OM indb cover5 9369313301_OM indb cover5 12 18 2017 11 38 03 AM 12 18 2017 11 38 03 AM ...