State of indicator lamps

Lighting pattern:   Off,     On,   

 Blinking,   

 Any state

State

Causes and solutions

See

page

Automatic defrosting operation

 

Please wait until finishing the defrosting 

(maximum of 15 minutes).

9

Filter indicator

 

Clean the air filter and reset the filter 

sign.

8

Error code display

 Consult authorized service personnel.

-

Timer setting error because of Auto restart

 Reset the clock and timer settings.

-

Test run operation (for authorized 

personnel only)

 Press 

 to quit the test run.

-

Restricted function

-

(Slow)

(Slow)

(In multi connection) Standby mode 

 Check the set operation mode of the 

indoor units.

9

 

Manual Auto operation and Filter indicator 

reset

You can operate the air conditioner with 

 on the 

indoor unit.

Status

Time to keep pressing

Mode or operation

In operation More than 3 seconds

Stop

Stopping

2 seconds or less

Filter indicator reset

More than 3 seconds and 

less than 10 seconds

Auto *

1)

More than 10 seconds

(Only for servicing.*

2)

)

Forced cooling

*1)   In multi connection, the operation mode follows the other indoor 

units.

*2)  To stop the forced cooling, press this button or

 

 

on the remote 

controller.

(3 times)

(Fast)

9387858020_OM.indb   11

2/8/2019   1:53:17 PM

Summary of Contents for ASY20MI-KM

Page 1: ...montage mural Avant d utiliser ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo montado en pared Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo montato a parete Prima di util...

Page 2: ...nsult authorized service personnel Take care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air ...

Page 3: ...rroundings of the outdoor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product...

Page 4: ...er to page 6 Activates the 10 C Heat operation 3 1 Indoor unit Remote controller signal receiver Horizontal airflow direction louvers For Manual Auto operation and Filter indicator reset Refer to page 11 Rating label Drain hose Indicator lamps 2 Front panel Air filter Intake grille 1 Air cleaning filter Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation...

Page 5: ...Powerful operation Refer to page 6 Activates or deactivates the Powerful operation For Airflow settings Refer to page 5 Controls the fan speed Sets the automatic Swing operation Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Sets the On...

Page 6: ... displayed as follows Timer Indicator on the remote controller display On Off timer Off On timer NOTES You can set the Program timer only within a span of 24 hours If you set the Sleep timer after setting the Program timer the Program timer is canceled 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode change...

Page 7: ...e Powerful operation When activated the indoor unit will emit 2 short beeps When deactivated the indoor unit will emit 1 short beep The Powerful operation will be turned off automatically in the following situations The Powerful operation runs for a certain amount of time and the room temperature reaches the set temperature in the Cooling Dry or Heating mode 20 minutes after the Powerful operation...

Page 8: ...ilter cleaning involves high place work please consult the authorized service personnel Do not touch the aluminum fins of heat exchanger built in the indoor unit to avoid personal injury when you maintain the unit Do not expose the indoor unit to liquid insecticides or hair sprays Do not stand on slippery uneven or unstable surfaces when you maintain the unit Intake grille Air filters Indoor unit ...

Page 9: ...dorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter Removing and installing intake grille Removing intake grille 1 Open the intake grille until it snaps 2 Pull the mounting shafts while keeping the intake grille in a horizontal position Inst...

Page 10: ...IONAL PARTS 12 1 Wired remote controller The optional wired remote controller can be used You can use wired and wireless remote controller together However some functions of the wireless remote controller are restricted If you set the restricted functions beeping sound will be heard and indicator on the indoor unit will blink Restricted functions for wireless remote controller When using together ...

Page 11: ...n the heating apparatus or computers off or set the temperature lower Refer to page 5 Airflow is weak or stops Is the fan speed set to Quiet To change the fan speed refer to page 5 In the Heating mode Have you just started the operation In this case the fan rotates at very low speed temporarily to warm up the internal parts of the unit In the Heating mode Is the room temperature higher than the se...

Page 12: ...test run Restricted function Slow Slow In multi connection Standby mode Check the set operation mode of the indoor units 9 Manual Auto operation and Filter indicator reset You can operate the air conditioner with on the indoor unit Status Time to keep pressing Mode or operation In operation More than 3 seconds Stop Stopping 2 seconds or less Filter indicator reset More than 3 seconds and less than...

Reviews: