Timer Operation

NOTES for timer settings:

Any interruption of the power supply, such as a blackout or cutting off 
of a circuit breaker, makes the set internal clock go wrong.
In such a case, the TIMER indicator on the indoor unit blinks, and you 
need to readjust the setting.

ON timer or OFF timer

You can set the ON timer or OFF timer with the following steps.

1

  Press the TIMER SETTING button to start the setting.

The WEEKLY indicator will be 

fl

 ashing on the remote controller.

2

  Press the SELECT button to choose the desired mode. The mode 

will change as follows:

WEEKLY

ON/OFF

(ON)

ON/OFF

(OFF)

ON/OFF

(ON

OFF)

SLEEP

(OFF)

3

  Press the NEXT button. Continue to setting for each mode.

* To cancel timer setting during the setting process, press the 

TIMER SETTING button again.

4

  Adjust the time by pressing the SELECT button while the clock 

indicator is blinking. Each time you press the button, the time will 
change by +5/-5 minutes. Pressing down will change the time by 
+10/-10 minutes.

5

  Press the SEND button.

To redo the timer setting, perform step 1 to 5 again.
To cancel the ON/OFF timer, press the ON/OFF button while the ON/
OFF indicator is on. (Erases the indicator)

Program timer (combined use of the ON timer and the OFF timer)

You can set an integrated ON–OFF or OFF–ON timer.
Either of the timer whose con

fi

 gured starting time is closer to the 

current time works 

fi

 rst, and the order of timer operation is displayed 

as follows:

Timer

Indicator on remote controller display

ON–OFF timer

OFF–ON timer

To set the program timer, conduct the same steps 

~

 for the ON/

OFF timer. (Select ON

OFF in Step 2)

NOTES:

• If you change the setting value for the timer after the program timer 

is set, the counting down of the timer will be reset at that moment.

• Time setting for each combination should be within a span of 24 hours.

SLEEP timer

To set the SLEEP timer, 

fi

 rst follow steps 

~

 for the ON/OFF timer.

4

  Adjust the time by pressing the SELECT button while the clock 

indicator is blinking.
Each time you press the button, the time changes as follows:

9H

00M

7H

00M

5H

00M

3H

00M

2H

00M

1H

00M

0H

30M

hours

(30 min.)

5

  Press the SEND button.

To cancel the SLEEP timer, press the SLEEP button while the SLEEP 
indicator is on. (Erases the indicator)

To help you to fall asleep comfortably and prevent excessive warming 
or cooling in sleep, the SLEEP timer controls the temperature setting 
automatically in accordance with the set time shown as follows. The 
air conditioner completely turns off after the set time has elapsed.

In HEAT mode

Set
temperature

Set time

1 hour

Set time

1 hour

1.5 hour

30 min.

1 °C 2 °C 3 °C 4 °C

2 °C

1 °C

In COOL or DRY mode

(continued)

 Remote controller custom code setting

When two or more air conditioners are installed in a room and the 
remote controller is operating an air conditioner other than the one you 
wish to set, change the custom code of the remote controller to operate 
only the air conditioner you wish to set (4 selections possible).
When two or more air conditioners are installed in a room, please 
contact your retailer to set the individual air conditioner custom codes.
Use the following steps to select the custom 
code of the remote controller.
(Note that the air conditioner cannot receive 
a signal if the air conditioner has not been set 
for the matching custom code.)
1.  Press the START/STOP button until only the 

clock is displayed on the remote controller 
display.

2.  Press the MODE button for at least 

fi

 ve 

seconds to display the current custom code 
(initially set to A).

3.  Press the SET TEMP. (  /  ) button to change the custom code 

between A

B

C

D.

Match the code on the display to the air conditioner custom code.

4.  Press the MODE button again to return to the clock display. The 

custom code will be changed.

•  If no buttons are pressed within 30 seconds after the custom code 

is displayed, the system returns to the original clock display. In this 
case, start again from step 1.

•  The air conditioner custom code is set to A prior to shipment.
   Contact our authorized service personnel to change the custom code.
•  Depending on the remote controller, the custom code may return to 

custom code A when the batteries are replaced. In this case,if you 
use a code other than A, reset the code after replacing the batter-
ies. If you do not know the air conditioner custom code setting,try 
each code A

B

C

D until you 

fi

 nd the code which operates the 

air conditioner.

 Wired Remote Controller (Option)

The optional wired remote controller can be used.
When you use remote controller, there are following different points as 
compared with using wireless remote controller.
[The additional functions for wired remote controller]
  • Temperature set back timer
And, you can use wired and wireless remote controller together.
However, you must change some restricted functions of wireless remote 
controller to invalid.
If restricted function is valid, remote controller cannot use correctly.
(beeping sound will be heard, OPERATION, TIMER and the ECONOMY 
indicator of the indoor unit will 

fl

 ash.)

[The restricted functions for wireless remote controller]
<Polar 3-core wired remote controller>
• Outdoor unit low noise
• Energy saving
• 10°C HEAT
• Powerful
• Timer operation
<Non-polar 2-core wired remote controller>
• Outdoor unit low noise
• 10°C HEAT
• Weekly timer
• Powerful

Remote Controller Overview and 

Operations (continued)

9320455040-02_OM_EN.indd   6

9320455040-02_OM_EN.indd   6

12/1/2017   11:01:10 AM

12/1/2017   11:01:10 AM

Summary of Contents for ASTG18KMCB

Page 1: ...ep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and refrain from touching the product or the power source to prevent any electrical hazards The appliance shall be stored in a room without continuously operating ignition sources for example open...

Page 2: ...se items Do not expose animals or plants to the direct airflow Do not drink the drainage from the air conditioner Do not pull the power supply cable to disconnect the plug Do not touch the aluminum fins of heat exchanger built in the indoor or outdoor unit to avoid personal injury when you install or maintain the unit Do not direct the airflow at fireplaces or heating apparatus Do not block or cov...

Page 3: ... may cause condensation to form and the drops may damage your property 7 Power diffuser In conjunction with movement of the vertical airflow direction louver the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 8 8 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow directi...

Page 4: ...is not available in FAN mode 4 Remote controller display In this section all the possible indicators are displayed for description In actual operation the display is linked with the button operation and only shows the necessary indicators for each setting 5 POWERFUL button Activates the POWERFUL operation The unit will operate at maximum power and strong airflow to quickly cool down or warm up the...

Page 5: ...s shown in this figure RESET 18 TEST RUN button Only used for the initial test in the unit installation Do not press this button under normal use because it will cause incorrect operation During the test run the OPERATION indicator and the TIMER indicator blink simultaneously To quit the test run that is started unintentionally you need to turn off the air conditioner by pressing the START STOP bu...

Page 6: ... C 4 C 2 C 1 C In COOL or DRY mode continued Remote controller custom code setting When two or more air conditioners are installed in a room and the remote controller is operating an air conditioner other than the one you wish to set change the custom code of the remote controller to operate only the air conditioner you wish to set 4 selections possible When two or more air conditioners are instal...

Page 7: ...se the WEEKLY timer together with the other timers If you want to run the product on WEEKLY timer after using the ON OFF timer Program timer or SLEEP timer while the WEEKLY timer is running you need to activate the WEEKLY timer again To set the WEEKLY timer first follow steps on page 6 for the ON OFF timer 4 Select the program number and the day using the SELECT button Program 1Week Program Monday...

Page 8: ...ch as oscillating electric fans operating Notice This product is designed to be compatible with Air Conditioning Demand Response program To utilize the function you need a separate arrangement with your electricity supplier Please check availability in the place of use When your electricity supplier activates one of the following 3 Demand Response DR modes the air conditioner switches over to the ...

Page 9: ...s Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner If you encounter such a malfunction turn off the circuit breaker once Then turn it on again and resume operation by using the remote controller Heating performance This air conditioner operates on the heat pump principle absorbing heat from ...

Page 10: ...it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating noise Clean the ...

Page 11: ...ng absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine particle ceramic To maintain the deodorizing effect clean the filter once every 3 months as follows 1 Remove the filter 2 Flush the filter with high pressure hot water until the surface of the filter is covered with water 3 Wash the filter gently with diluent neutral detergent Do not wash it by wringing ...

Page 12: ... adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airflow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 4 When monitoring operation is performed in AUTO mode the fan rotates at very low speed Outdoor unit emits water During heating operation the outdoor unit...

Reviews: