background image

En-2

Control unit (optional)

Types of remote controllers:

● Wireless remote controller

● Wired remote controller

● Simple remote controller

For operation method, please refer to the Operating Manual of each 

device.

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote control unit is 

lost or otherwise unavailable.

 CAUTION

Do not press the MANUAL AUTO button with wet hands or pointed ob-

jects, otherwise an electric shock or malfunction may occur.

Starting Operation

Press the MANUAL AUTO button on the operating 

control panel.

The operation can be set in the following setting.

Operating mode

AUTO:

When Auto mode cannot be selected, it will 

operate in the same mode as the other indoor 

unit in the same system. (When other indoor 

unit in the same system doesn’t operate, the air 

conditioner will operate in cooling.)

Fan speed

AUTO

Setting temperature 23 °C

Stopping Operation

Press the MANUAL AUTO button on the operating 

control panel.

ADJUSTING THE DIRECTION OF 

AIR CIRCULATION

The vertical wind direction can be controlled with the control unit. The 

horizontal wind direction can also be controlled in the same manner.

Vertical direction

Horizontal direction

(1)

(2)

(3)

(4)

(5)

(1)

(2)

(3)

(4)

(5)

Cooling & Dry: (1), [(2)], (3), (4), (5)

Heating: 

(1), [(2)], (3), (4), (5)

[  ]:  Can only be set with the wire-

less remote controller

Cooling & Dry : (1), (2), (3), (4), (5)

Heating : 

(1), (2), (3), (4), (5)

OPERATING TIPS

Operation and Performance

About priority state and standby state

 

Multiple indoor units can be connected within the same system. De-

pending on the system, choice of operating mode are limited.

Cooling priority state:

When the other indoor units within the same system operate in cooling or 

dry mode, heating can not be selected at the same time.

Heating priority state:

When the other indoor units within the same system operate in heating 

mode, cooling and dry mode can not be selected at the same time.

Standby state:

The standby state activates when two or more indoor units start up at 

the same time in different mode. Any indoor unit other than priority mode 

will wait in standby state until priority mode changes (operation starts as 

soon as priority is switched).

At this time, the operation indicator lamp (green) lights up and the timer 

indicator lamp (orange) flashes.

Low ambient cooling

 

When the outdoor temperature drops, the outdoor unit's fans may 

switch to Low Speed, or one of the fans may stop intermittently.

Heating performance

 

Heating mode operates on the heat-pump principle, absorbing heat 

from outdoor air and transferring that heat indoors. As a result, the 

operating performance is reduced as outdoor air temperature drops. 

If you feel that insufficient heating performance is being produced, we 

recommend you use this air conditioner in conjunction with another 

type of heating appliance.

 

Heating mode heat your entire room by recirculating air throughout the 

room, with the result that some time may be required after first starting 

the air conditioner until the room is heated.

Microcomputer-controlled automatic defrosting

 

When using the Heating mode under conditions of low outdoor air 

temperature high humidity, frost may form on the outdoor unit, result-

ing in reduced operating performance. In order to prevent this kind of 

reduced performance, this unit is equipped with a Microcomputer-con-

trolled automatic defrosting function. If frost forms, the air conditioner 

will temporarily stop, and the defrosting circuit will operate briefly (for 

about 4 to 15 minutes). 

During Automatic Defrosting operation, the OPERATION indicator 

lamp (green) will flash.

Oil recovery operation

 

Periodically, the oil recovery operation is performed in order to return 

compressor oil to the outdoor unit.  

During oil recovery operation, the OPERATION indicator lamp (green) 

will flash (for about 10 minutes).

Temperature and humidity range

 

The temperature and humidity required for operating this product is as 

shown in the following table.

Cooling/Dry Mode

Heating Mode

Outdoor  

temperature

Please refer to the specification of outdoor units.

Indoor  

temperature

18 to 32 °C DB

10 to 30 °C DB

Indoor humidity

About 80% or less

 

If the air conditioner is operated under higher temperature conditions 

than those listed, the built-in protection circuit may operate to prevent 

internal circuit damage. Also, during Cooling and Dry modes, if the unit 

is used under conditions of lower temperature than those listed above, 

the heat-exchanger may freeze, leading to water leakage and other 

damage.

 

If the unit is used for long periods under high-humidity conditions, 

condensation may form on the surface of the indoor unit, and drip onto 

the floor or other objects underneath.

 

Do not use this unit for any purposes other than the Cooling, Heating, 

Dehumidifying, and air-circulation of rooms in ordinary dwellings.

9377772299_OM.indb   2

30/01/2017   14:11:38

Summary of Contents for ASHA18GBCH

Page 1: ...ελλοντική αναφορά MANUAL DE FUNCIONAMENTO UNIDADE INTERIOR Tipo mural Guarde este manual para consulta futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ настенного типа Сохраните данное руководство для последующего использования KULLANIM KILAVUZU İÇ ÜNİTE Duvara Monteli Tip Bu kılavuzu ileride başvurmak üzere saklayın MODE D EMPLOI UNITÉ INTÉRIEURE Type montage mural Conservez ce manuel pour po...

Page 2: ...is section all relate to safety be sure to maintain safe operating conditions WARNING and CAUTION have the following meanings in these instructions WARNING This mark indicates procedures which if im properly performed might lead to the death or serious injury of the user CAUTION This mark indicates procedures which if im properly performed might possibly result in per sonal harm to the user or dam...

Page 3: ...t s fans may switch to Low Speed or one of the fans may stop intermittently Heating performance Heating mode operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditio...

Page 4: ...me Hook 2 places at the rear Latch 2 places Take care that the air cleaning filter does not project beyond the frame 3 Engage the four fixing locations at the top and bottom of the air cleaning filter frame with the hooks of the air filter Rear of the filter Fixing location hook 6 places CLEANING AND CARE CAUTION Before cleaning the unit be sure to stop the unit and disconnect the power supply Be ...

Page 5: ...tion during that period Airflow is weak or stops When Heating operation is started indoor unit s fan may temporarily stop to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit s fan will stop If you wish to warm the room further set the thermostat for a higher setting During oil recovery...

Page 6: ...m the priority state See page 2 Is it in standby state See page 2 The operation mode cannot be changed Are you trying to change to an operation different from the priority conditions See page 2 Poor Cooling or Heating performance Did you adjust the room temperature settings thermostat correctly Is the air filter dirty See page 3 Are the air conditioner s inlet port or outlet port blocked Is there ...

Page 7: ...9377772299_OM indb 6 30 01 2017 14 11 39 ...

Page 8: ...9377772299_OM indb 8 30 01 2017 14 11 58 ...

Reviews: