En-6
Steam comes out of the indoor unit:
● During Heating operation, the outdoor unit’s fan may stop, and steam
may be seen rising from the unit. This is due to the Automatic defrost-
ing operation. (Refer to “OPERATING TIPS”)
Water is produced from the outdoor unit:
● During Heating operation, water may be produced from the outdoor
unit due to the Automatic defrosting operation.
The following conditions may not be breakdowns so
check again.
Doesn’t operate at all:
● Has there been a power failure?
● Has a fuse blown out, or a circuit breaker been tripped?
● Is the main power switch set to the OFF position?
● Are you trying to engage in an operation diff erent from the priority
state? (Refer to “OPERATING TIPS”)
● Is it in standby state? (Refer to “OPERATING TIPS”)
● Is the Auto-off operation of the Human sensor setting active? (Refer to
“HUMAN SENSOR”)
The operation mode cannot be changed:
● Are you trying to change to an operation diff erent from the priority
conditions? (Refer to “OPERATING TIPS”)
Poor Cooling (or Heating) performance:
● Did you adjust the room temperature settings (thermostat) correctly?
● Is the air fi lter dirty? (Refer to “CLEANING AND CARE”)
● Are the air conditioner’s inlet port or outlet port blocked?
● Is there a window or door open?
● In the case of Cooling operation, is a window allowing bright sunlight to
enter? (Close the curtains.)
● In the case of Cooling operation, are there heating apparatus and com-
puters inside the room, or are there too many people in the room?
● Is the fan speed set to low?
● Is the Auto saving operation of the Human sensor setting active? (Re-
fer to “HUMAN SENSOR”)
Set the temperature lower than the room temperature and use it:
● Temperature does not fall down well.
Temperature may not fall down depending on the room conditions.
(While high humidity or the room temperature is high.) (Refer to “OP-
ERATING TIPS”)
In following situations stop operation immediately and
get in touch with authorized service personnel.
● The problem cannot be solved even when the troubleshooting checks
have been performed.
● The FILTER indicator lamp (red) is blinking very fast.
● The wired remote controller or simple remote controller indicate Er
(when connected).
● It has burning smell.
SPECIFICATIONS
Model
AS*A004
GCGH
AS*A007
GCGH
AS*A009
GCGH
AS*A012
GCGH
AS*A014
GCGH
Power source
220 - 240 V ~ 50 Hz, 230 V ~ 60 Hz
Available voltage
range
198 to 264 V (50 Hz)
198 to 253 V (60 Hz)
Cooling
capacity
[kW]
1.1
2.2
2.8
3.6
4.0
[Btu/h]
3800
7500
9600
12300
13600
Heating
capacity
[kW]
1.3
2.8
3.2
4.0
4.5
[Btu/h]
4400
9600
10900
13600
15400
Input power
[W]
12
16
20
25
36
Current
[A]
0.12
0.16
0.18
0.25
0.30
Sound pressure level
High
dB [A]
31
34
37
40
44
Med - high
dB [A]
30
32
35
37
42
Med
dB [A]
28
30
32
35
40
Med - low
dB [A]
27
28
29
33
37
Low
dB [A]
26
26
26
30
34
Quiet
dB [A]
22
22
22
24
24
Dimensions and weight
Height
[mm]
268
Width
[mm]
840
Depth
[mm]
203
Weight
[kg]
8.5
Model
AS*E004
GCEH
AS*E007
GCEH
AS*E009
GCEH
AS*E012
GCEH
AS*E014
GCEH
Power source
220 - 240 V ~ 50 Hz, 230 V ~ 60 Hz
Available voltage
range
198 to 264 V (50 Hz)
198 to 253 V (60 Hz)
Cooling
capacity
[kW]
1.1
2.2
2.8
3.6
4.0
[Btu/h]
3800
7500
9600
12300
13600
Heating
capacity
[kW]
1.3
2.8
3.2
4.0
4.5
[Btu/h]
4400
9600
10900
13600
15400
Input power
[W]
12
16
20
25
36
Current
[A]
0.12
0.16
0.18
0.25
0.30
Sound pressure level
High
dB [A]
31
34
37
40
44
Med - high
dB [A]
30
32
35
37
42
Med
dB [A]
28
30
32
35
40
Med - low
dB [A]
27
28
29
33
37
Low
dB [A]
26
26
26
30
34
Quiet
dB [A]
22
22
22
24
24
Dimensions and weight
Height
[mm]
268
Width
[mm]
840
Depth
[mm]
203
Weight
[kg]
8.5
● Acoustic noise information:
The maximum sound pressure level is less than 70 dB (A) for both
indoor unit and outdoor unit. According IEC 704-1 and ISO 3744.
● This product contains fl uorinated greenhouse gases.