Steam comes out of the indoor unit:

 

● During Heating operation, the outdoor unit’s fan may stop, and steam 

may be seen rising from the unit. This is due to the Automatic defrost-
ing operation. (Refer to “OPERATING TIPS”)

Water is produced from the outdoor unit:

 

● During Heating operation, water may be produced from the outdoor 

unit due to the Automatic defrosting operation.

The following conditions may not be breakdowns so 
check again.

Doesn’t operate at all:

 

● Has there been a power failure?

 

● Has a fuse blown out, or a circuit breaker been tripped?

 

● Is the main power switch set to the OFF position?

 

● Are you trying to engage in an operation diff erent from the priority 

state? (Refer to “OPERATING TIPS”)

 

● Is it in standby state? (Refer to “OPERATING TIPS”)

 

● Is the Auto-off  operation of the Human sensor setting active? (Refer to 

“HUMAN SENSOR”)

The operation mode cannot be changed:

 

● Are you trying to change to an operation diff erent from the priority 

conditions? (Refer to “OPERATING TIPS”)

Poor Cooling (or Heating) performance:

 

● Did you adjust the room temperature settings (thermostat) correctly?

 

● Is the air fi lter dirty? (Refer to “CLEANING AND CARE”)

 

● Are the air conditioner’s inlet port or outlet port blocked?

 

● Is there a window or door open?

 

● In the case of Cooling operation, is a window allowing bright sunlight to 

enter? (Close the curtains.)

 

● In the case of Cooling operation, are there heating apparatus and com-

puters inside the room, or are there too many people in the room?

 

● Is the fan speed set to low?

 

● Is the Auto saving operation of the Human sensor setting active? (Re-

fer to “HUMAN SENSOR”)

Set the temperature lower than the room temperature and use it:

 

● Temperature does not fall down well. 

Temperature may not fall down depending on the room conditions. 
(While high humidity or the room temperature is high.) (Refer to “OP-
ERATING TIPS”)

In following situations stop operation immediately and 
get in touch with authorized service personnel.

 

● The problem cannot be solved even when the troubleshooting checks 

have been performed.

 

● The FILTER indicator lamp (red) is blinking very fast.

 

● The wired remote controller or simple remote controller indicate Er 

(when connected).

 

● It has burning smell.

SPECIFICATIONS

Model

AS*A004

GCGH

AS*A007

GCGH

AS*A009

GCGH

AS*A012

GCGH

AS*A014

GCGH

Power source

220 - 240 V ~ 50 Hz, 230 V ~ 60 Hz

Available voltage 
range

198 to 264 V (50 Hz)
198 to 253 V (60 Hz)

Cooling 
capacity

[kW]

1.1

2.2

2.8

3.6

4.0

[Btu/h]

3800

7500

9600

12300

13600

Heating 
capacity

[kW]

1.3

2.8

3.2

4.0

4.5

[Btu/h]

4400

9600

10900

13600

15400

Input power

[W]

12

16

20

25

36

Current

[A]

0.12

0.16

0.18

0.25

0.30

Sound pressure level

High

dB [A]

31

34

37

40

44

Med - high

dB [A]

30

32

35

37

42

Med

dB [A]

28

30

32

35

40

Med - low

dB [A]

27

28

29

33

37

Low

dB [A]

26

26

26

30

34

Quiet

dB [A]

22

22

22

24

24

Dimensions and weight

Height

[mm]

268

Width

[mm]

840

Depth

[mm]

203

Weight

[kg]

8.5

Model

AS*E004

GCEH

AS*E007

GCEH

AS*E009

GCEH

AS*E012

GCEH

AS*E014

GCEH

Power source

220 - 240 V ~ 50 Hz, 230 V ~ 60 Hz

Available voltage 
range

198 to 264 V (50 Hz)
198 to 253 V (60 Hz)

Cooling 
capacity

[kW]

1.1

2.2

2.8

3.6

4.0

[Btu/h]

3800

7500

9600

12300

13600

Heating 
capacity

[kW]

1.3

2.8

3.2

4.0

4.5

[Btu/h]

4400

9600

10900

13600

15400

Input power

[W]

12

16

20

25

36

Current

[A]

0.12

0.16

0.18

0.25

0.30

Sound pressure level

High

dB [A]

31

34

37

40

44

Med - high

dB [A]

30

32

35

37

42

Med

dB [A]

28

30

32

35

40

Med - low

dB [A]

27

28

29

33

37

Low

dB [A]

26

26

26

30

34

Quiet

dB [A]

22

22

22

24

24

Dimensions and weight

Height

[mm]

268

Width

[mm]

840

Depth

[mm]

203

Weight

[kg]

8.5

 

●  Acoustic noise information: 

The maximum sound pressure level is less than 70 dB (A) for both 
indoor unit and outdoor unit. According IEC 704-1 and ISO 3744.

 

● This product contains fl uorinated greenhouse gases.

9377772428-01_OM.indb   6

9377772428-01_OM.indb   6

4/1/2020   1:16:51 PM

4/1/2020   1:16:51 PM

Summary of Contents for AS A004GCGH Series

Page 1: ...ahme auf MANUALE DI ISTRUZIONI UNITÀ INTERNA tipo montato a parete Conservare questo manuale per consultazione futura ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Επιτοιχιος τύπος Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ настенного типа Сохраните данное руководство для последующего использования KULLANIM KILAVUZU İÇ ÜNİTE Duvara monteli tip Bu ...

Page 2: ...h if im properly performed might lead to the death or serious injury of the user CAUTION This mark indicates procedures which if im properly performed might possibly result in per sonal harm to the user or damage to property PRECAUTIONS ON USE WARNING Do not keep exposing oneself to the direct wind of air conditioner for a long time Do not insert fingers or objects into the outlet port or intake gr...

Page 3: ... system doesn t operate the air conditioner will operate in cooling Fan speed AUTO Setting temperature 23 C Stopping Operation Press the MANUAL AUTO button on the operating control panel AIRFLOW DIRECTION Vertical airflow direction The vertical wind direc tion can be controlled with the remote control ler Cooling and Dry Heating 1 2 3 4 1 2 3 4 Horizontal airflow direction The horizontal airflow dire...

Page 4: ...TES Energy Saving function may not work when the room temperature is very different from the temperature defined in temperature setting such as when immediately after starting the operation Since the Human sensor detects infrared light given out by people there may be cases where this detection is incorrect Situations in which the sensor will detect no people in the room even when there is someone t...

Page 5: ...ing it downward c a b b a c 3 Filter holder and air cleaning filter are attached on the rear side of the air filter Remove them from the air filter by unlatching each corner of the filter holder d d d d d 4 Remove dust by using a vacuum cleaner or by washing the filter When you wash the filter use neutral household detergent and warm water After rinse the filter well dry it thoroughly in a shaded place b...

Page 6: ...s preventing unit operation during that period Airflow is weak or stops When Heating operation is started indoor unit s fan may temporarily stop to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit s fan will stop If you wish to warm the room further set the thermostat for a higher setti...

Page 7: ...igh Refer to OP ERATING TIPS In following situations stop operation immediately and get in touch with authorized service personnel The problem cannot be solved even when the troubleshooting checks have been performed The FILTER indicator lamp red is blinking very fast The wired remote controller or simple remote controller indicate Er when connected It has burning smell SPECIFICATIONS Model AS A00...

Page 8: ...9377772428 01_OM_AR indd i 9377772428 01_OM_AR indd i 4 1 2020 1 24 08 PM 4 1 2020 1 24 08 PM ...

Reviews: