En-32
Water is produced from the outdoor unit
*
•
During heating operation, water may be produced from the
outdoor unit due to the automatic defrosting operation.
<<SEE PAGE 33>>
The filter indicator blinks
• Clean the filter. Afterwards, turn the Filter indicator off.
<<SEE PAGE 24>>
thermo sensor display on the remote controller is
flashing
•
The room temperature sensor may be malfunctioning.
Please consult authorized service personnel.
Airflow is stopped and
is displayed on the icon
display of the “Monitor” screen
• Airflow is stopped due to the automatic defrosting, oil
recovery, or mode mismatch.
Order of timer patterns from [Time 1] to [Time 8] in
[Weekly timer setting] is different from what you
registered
•
If more than 2 timer patterns per a day are registered in
[Weekly timer setting] and they are not in proper time
order, those patterns are sorted automatically in time
order when you finalize the [Weekly timer setting]. (Sort
-
ing function)
<<SEE PAGE 13>>
Humidity does not drop
In the case of dry operation.
•
In some conditions of the room, the humidity does not
drop.
•
In order to lower the humidity, set a lower room tempera-
ture.
z
Check once more
Does not operate at all
•
Has the circuit breaker been turned off?
•
Has there been a power failure?
•
Has a fuse blown out, or a circuit breaker been tripped?
•
Is the timer operating?
•
Is key lock enabled?
<<SEE PAGE 26>>
Poor cooling (or heating*) performance
• Is the air filter dusty?
•
Are the air conditioner’s intake grille or outlet port blocked?
•
Did you adjust the room temperature settings
(thermostat) correctly?
•
Is there a window or door open?
•
In the case of cooling operation, is a window allowing
bright sunlight to enter? (Close the curtains.)
•
In the case of cooling operation, are there heating
apparatus and computers inside the room, or are there
too many people in the room?
•
In the unit set for quiet operation?
•
Do you have an arrangement with your electric company
for demand response?
Following functions cannot be set:
• Economy
• Set temp. auto return
• Set temp. range limitation
• On timer
• Off timer
• Weekly timer
• Auto-off timer
•
If the function you are selecting is restricted by
[Management] function, following message is displayed
in the operation guidance display.
XXXXXX
XXXXXX
Restricted by the management function
Back:
•
Has the function setting been set to [Enable] or [On]?
On timer or Off timer does not work
•
Has there been a power outage? Any power outage
cancels the On or Off timer.
•
After the power supply is resumed, set the [Enable/
Disable setting] to [Enable] again.
<<SEE PAGE 12, 13>>
Weekly timer does not work
•
Have all the necessary settings been completed in
[Weekly timer setting]?
<<SEE PAGE 13 to 20>>
Operation is automatically stopped
•
Has off timer been set?
•
Has weekly timer been set?
<<SEE PAGE 13>
•
Has auto-off timer been set?
<<SEE PAGE 20>>
Operation does not stopped even if auto-off timer has
been set
•
Has the operation been started by pressing the [On/Off
button] on this remote controller?
•
Has the operation been started by weekly timer or on timer?
•
Has the weekly timer been on during the counting down
of the Auto-off timer?
•
Has it been within the valid hour?
<<SEE PAGE 20>>
•
Has there been a power outage? Any power outage can-
cels the Auto-off timer.
•
Is message [R.C. prohibition (All, on/off)] and
icon
displayed?
<<SEE PAGE 4>>
Set temperature is changed automatically
•
Has set temp. auto return been set?
<<SEE PAGE 10>>
Does not return to the set temperature
•
Has set temp. auto return been set?
<<SEE PAGE 11>>
Set temperature cannot be changed
•
Has set temp. range limitation been set?
<<SEE PAGE 11>>
•
Is message [R.C. prohibition (Set temp. all)] and
icon
displayed?
<<SEE PAGE 4>
If the problem persists after performing these checks, or
if you notice burning smells, stop operation immediately,
disconnect the power supply, and consult with authorized
service personnel.