If you use a wireless remote control, the lamp
on the photo detector unit will output error codes
by way of blinking patterns.
If you use a wired type remote control, error
codes will appear on the remote control display.
See the lamp blinking patterns and error codes
in the table. An error display is displayed only
during running.
Indoor unit lamps
Wired
remote
control
INDOOR UNIT
and WIRED REMOTE CONTROL
ERROR DETECTION
Description
OPERATION
(green)
TIMER
(orange)
ECONOMY
(green)
(1)
(1)
Serial communication error
(1)
(2)
Wired remote control
communication error
(2)
(3)
Combination error
(3)
(2)
Indoor unit PCB model
information error
(3)
(5)
Manual auto switch error
(4)
(1)
Inlet air temp. sensor error
(4)
(2)
Indoor unit Heat Ex. Middle
temp. sensor error
(5)
(1)
Indoor unit fan motor error
(5)
(3)
Drain pump error
(6)
(2)
Outdoor unit main PCB model
information error
or communication error
(6)
(3)
Inverter error
(6)
(4)
PFC circuit error
(6)
(5)
Trip terminal Lerror
: 0.5s on / 0.5s off
: 0.1s on / 0.1s off
( ) : Number of flashing
This is possible only on a wired remote control.
If an error occurs, the following display will be shown.
(“Er” will appear in the set room temperature display.)
2013.11.20
17
(7)
(1)
Discharge temp. sensor error
(7)
(2)
Compressor temp. sensor error
(9)
(4)
Trip detection
(9)
(5)
Compressor rotor position
detection error (permanent stop)
(9)
(7)
Outdoor unit fan motor error
(9)
(9)
4-way valve error
Coil (expansion valve) error
Outdoor unit fan motor 2 error
(10)
(1)
Discharge temp. error
(10)
(3)
Compressor temp. error
(10)
(5)
Low pressure error
Indoor unit lamps
Wired
remote
control
Description
OPERATION
(green)
TIMER
(orange)
ECONOMY
(green)
(9)
(8)
(9)
(10)
(7)
(3)
Outdoor unit Heat Ex. liquid
temp. sensor error
(7)
(4)
Outdoor temp. sensor error
(7)
(7)
Heat sink temp. sensor error
(8)
(4)
Current sensor error
(8)
(6)
High pressure switch error
Remote control
.
Error code
Unit number of
indoor unit
EX. Self-diagnosis
Indoor unit display (option)
ECONOMY
Lamp
(GREEN)
TIMER Lamp
(ORANGE)
OPERA
T
ION Lamp
(GREEN)
MANUAL
AUT
O