INSTALLATION MANUAL

For authorized service personnel only.

INSTALLATIONSANLEITUNG

Nur für autorisiertes Personal.

MANUEL D'INSTALLATION

Pour le personnel agréé uniquement.

MANUAL DE INSTALACIÓN

Solo para personal autorizado.

MANUALE D'INSTALLAZIONE

Ad uso esclusivo del personale autorizzato.

ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ

Για εξουσιοδοτημένο προσωπικό σέρβις.

MANUAL DE INSTALAÇÃO

Apenas para técnicos autorizados.

РУКОВОДСТВО ПО УСТАНОВКЕ

Для уполномоченного персонала.

KURULUM KILAVUZU

Yetkili servis personeli içindir.

INSTALLATION MANUAL

AIR CONDITIONER
OUTDOOR UNIT

PART NO. 9377863119

9377863119_IM.indb   1

9377863119_IM.indb   1

1/20/2011   6:07:25 PM

1/20/2011   6:07:25 PM

Summary of Contents for AOYG18LFCA

Page 1: ...uement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION MANUAL AIR CONDITIONER OUTDOOR UNIT PART ...

Page 2: ...ontents of change Gauge manifold Pressure is high and cannot be measured with a conven tional R22 gauge To prevent erroneous mixing of other refrigerants the diameter of each port has been changed It is recommended the gauge with seals 0 1 to 5 3 MPa 1 to 53 bar for high pressure 0 1 to 3 8 MPa 1 to 38 bar for low pressure Charge hose To increase pressure resistance the hose material and base size...

Page 3: ... 3 1 Outdoor unit 1 If possible do not install the unit where it will be exposed to direct sunlight If necessary Install a blind that does not interfere with the air flow 2 Do not install the unit where a strong wind blows or where it is very dusty 3 Do not install the unit where people pass 4 Take you neighbors into consideration so that they are not disturbed by air blowing into their windows or...

Page 4: ...r the terminal screw tightening torques Tightening torque M4 screw 1 2 to 1 8 N m 12 to 18 kgf cm M5 screw 2 0 to 3 0 N m 20 to 30 kgf cm Strip 10 mm Crimp type terminal Sleeve Wire Wire Screw with special washer Terminal board Terminal block Screw with special washer Crimp type terminal Crimp type terminal CAUTION Match the terminal block numbers and connection cable colors with those of the indo...

Page 5: ...Pa 76 cmHg 1 bar Tightening torque Blank cap 2 way valve 20 0 to 25 0 N m 200 to 250 kgf cm Blank cap 3 way valve 28 0 to 32 0 N m 280 to 320 kgf cm Charging port cap 12 5 to 16 0 N m 125 to 160 kgf cm 5 7 TEST RUN Perform test operation and check items below For the test operation method refer to the operating manual The outdoor unit may not operate depending on the room temperature In this case ...

Page 6: ...9377863119_IM indb 5 9377863119_IM indb 5 1 20 2011 6 22 23 PM 1 20 2011 6 22 23 PM ...