4. Refrigerant circuit
4-1. Model: AOYG18KMTA
2-way
valve
Strainer
Strainer
3-way
valve
Muffler
Muffler
Acccumlator
4-way valve
Expansion valve
Heat exchanger
( INDOOR )
Heat exchanger
( OUTDOOR )
Compressor
Cooling
Heating
Th
D
Th
R
Th
PI
Th
HO
Th
O
Th
R
Th
PI
Th
D
Th
O
Th
HO
:Thermistor (Room temperature)
:Thermistor (Pipe temperature)
:Thermistor (Discharge temperature)
:Thermistor (Outdoor temperature)
:Thermistor (Heat exchanger out temperature)
- 40 -
4-1. Model: AOYG18KMTA
4. Refrigerant circuit
OUTDOOR UNIT
AOYG18, 24KMTA
OUTDOOR UNIT
AOYG18, 24KMTA