6. Capacity compensation rate for pipe length and height
difference
Height difference H
Indoor unit is higher than outdoor unit
*
1
Indoor unit is lower than outdoor unit
*
2
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
H
H
6-1. Model: AOYG18KLTA
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Pipe length (m)
5
7.5
10
15
20
25
Height difference H (m)
Indoor unit is higher than
outdoor unit *1
20
—
—
—
—
0.872
0.848
15
—
—
—
0.904
0.879
0.854
10
—
—
0.951
0.919
0.893
0.868
7.5
—
0.972
0.955
0.923
0.897
0.872
5
0.992
0.975
0.959
0.925
0.901
0.876
0
1.000
0.983
0.967
0.933
0.908
0.883
Indoor unit is lower than
outdoor unit *2
-5
1.000
0.983
0.967
0.933
0.908
0.883
-7.5
—
0.983
0.967
0.933
0.908
0.883
-10
—
—
0.967
0.933
0.908
0.883
-15
—
—
—
0.933
0.908
0.883
-20
—
—
—
—
0.908
0.883
HEATING
Pipe length (m)
5
7.5
10
15
20
25
Height difference H (m)
Indoor unit is higher than
outdoor unit *1
20
—
—
—
—
0.863
0.857
15
—
—
—
0.869
0.863
0.857
10
—
—
0.934
0.869
0.863
0.857
7.5
—
0.967
0.934
0.869
0.863
0.857
5
1.000
0.967
0.934
0.869
0.863
0.857
0
1.000
0.967
0.934
0.869
0.863
0.857
Indoor unit is lower than
outdoor unit *2
-5
0.995
0.962
0.930
0.864
0.859
0.853
-7.5
—
0.960
0.928
0.862
0.856
0.850
-10
—
—
0.926
0.860
0.854
0.848
-15
—
—
—
0.852
0.846
0.840
-20
—
—
—
—
0.842
0.836
- 35 -
OUTDOOR UNIT
AOYG18, 24KLTA
Summary of Contents for AOYG18KLTA
Page 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG18KLCA ASYG24KLCA ...
Page 10: ...3 Wiring diagrams 3 1 Models ASYG18KLCA and ASYG24KLCA 6 WALL MOUNTED ASYG18 24KLCA ...
Page 28: ... 24 WALL MOUNTED ASYG18 24KLCA ...
Page 29: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG18KLTA AOYG24KLTA ...
Page 38: ...5 Wiring diagrams 5 1 Model AOYG18KLTA 5 2 Model AOYG24KLTA 34 OUTDOOR UNIT AOYG18 24KLTA ...