CAPACITY COMPENSATION RATE FOR PIPE LENGTH
5.
AND HEIGHT DIFFERENCE
MODEL
: AO
G09LT
Height difference H
1 Indoor unit is upper than outdoor unit.
2 Indoor unit is under than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
HEATING
Pipe length (m)
5
7.5
10
15
20
Height
difference H
(m)
1
Indoor unit is
upper than
outdoor unit.
15
-
-
-
0.896 0.879
10
-
-
0.968 0.890 0.879
7.5
-
0.994 0.968 0.896 0.879
5
1.000 0.994 0.968 0.896 0.879
0
1.000 0.994 0.968 0.896 0.879
2
Indoor unit is
under than
outdoor unit
-5
0.995 0.989 0.963 0.891 0.875
-7.5
-
0.987 0.961 0.889 0.873
-10
-
-
0.959 0.887 0.871
-15
-
-
-
0.878 0.862
COOLING
Pipe length (m)
5
7.5
10
15
20
Height
difference H
(m)
1
Indoor unit is
upper than
outdoor unit.
15
-
-
-
0.858 0.868
10
-
-
0.929 0.872 0.882
7.5
-
0.960 0.933 0.876 0.885
5
0.992
0.964 0.937 0.879 0.889
0
1.000 0.972 0.944 0.887 0.896
2
Indoor unit is
under than
outdoor unit
-5
1.000 0.972 0.944 0.887 0.896
-7.5
-
0.972 0.944 0.887 0.896
-10
-
-
0.944 0.887 0.896
-15
-
-
-
0.887 0.896
Summary of Contents for AOYG09LTCN
Page 2: ...1 INDOOR UNIT WALL MOUNTED TYPE AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01 2011 09 21 ...
Page 11: ... 01 08 WALL MOUNTED TYPE AS G09 14LT WALL MOUNTED TYPE AS G09 14LT INSTALLATION PLACE Unit mm ...
Page 35: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LTCN AO G12LTCN AO G14LTCN DTR_AO092E_01 2011 09 21 ...
Page 43: ... 02 07 OUTDOOR UNIT AO G09 14LT OUTDOOR UNIT AO G09 14LT MODEL AO G14LT ...
Page 51: ... 02 15 OUTDOOR UNIT AO G09 14LT OUTDOOR UNIT AO G09 14LT SOUND LEVEL CHECK POINT 8 2 ...