Following 2 types of air cleaning 

¿

 lters are used in this product.

When you replace them, purchase dedicated air cleaning 

¿

 lters for this 

product.

APPLE-CATECHIN FILTER: UTR-FA16

 

(1 sheet)

With using static electricity, puri

¿

 es the air by removing 

¿

 ne particles 

or dust such as tabacco smoke or plant pollen.

• This 

¿

 lter is disposable. Do not wash or reuse it.

•  Once you open the package, use it as soon as possible. The 

cleaning effect is reduced if the 

¿

 lter is left the package opened.

• Replace the 

¿

 lter once every 3 months under normal use.

• With setting the fan speed high, the air cleaning effect increases.

ION DEODORIZATION FILTER (light blue): UTR-FA16-2

 

(Light blue, 1 sheet)

Contained super micro-ceramic particles produce negative air ions, 
that is considered to have deodorizing effect, absorb and reduce 
room smell.

• To maintain the deodorizing effect, clean the 

¿

 lter once every 3 

months as follows:

1.

  Remove the ion deodorization 

¿

 lter.

2.

   Flush the 

¿

 lter with high-pressure hot water until the surface of 

the 

¿

 lter is covered with water.

3.

   Wash the 

¿

 lter gently with diluent nuetral detergent. Do not wash 

it by wringing or rubbing to prevent reducing the deodorizing 
effect by damage.

4.

  Rinse the 

¿

 lter well with water 

À

 ow.

5.

  Dry the 

¿

 lter throughly in shaded place.

6.

  Reinstall the ion deodorization 

¿

 lter to the indoor unit.

• Replace the 

¿

 lter once every 3 years under normal use.

After extended non-use of the unit

If you have shut down the indoor unit for 1 month or more, perform the 
FAN operation for half a day to dry the internal parts throughly before 
you perform normal operation.

Additional inspection

After long period of use, accumulated dust inside the indoor unit may 
reduce the product performance even if you have maintained the unit 
with instructed daily care or cleaning procedures written in this manual.

In such a case, the product inspection is recommended.

For more information, consult authorized service personnel.

Replacing the air cleaning 

¿

 lter

1

  Remove the air 

¿

 lter. (Refer to step 1 in “Replacing the air 

¿

 lter”.)

2

  Release 2 latches 

a

 of the 

¿

 lter holder, and turn over the holder 

in direction of arrow 

b

.

Remove the soiled air cleaning 

¿

 lter 

c

.

Note:

 Air 

cleaning 

¿

 lter is attached on each air 

¿

 lter.

a

a

b

c

3

  Attach new or maintained air cleaning 

¿

 lter 

to the 

¿

 lter holder.

New air cleaning 

¿

 lter can be attached to either of the right holder 

or the left holder.

d

4

  Latch 2 corners of the 

¿

 lter holder 

e

 to the air 

¿

 lter 

¿

 rmly.

e

e

5

  Reinstall the air 

¿

 lter. (Refer to step 6 in “Cleaning the air 

¿

 lter”.)

6

  Close the intake grille 

¿

 rmly.

(Refer to step 4 in “Cleaning the intake grille”.)

Care and Cleaning

9333003047_OM.indb   7

6/28/2013   11:46:21 AM

Summary of Contents for aoyg09lmca

Page 1: ...ot install the unit in area lled with mineral oil such as a factory or area containing a large amount of splashed oil or steam such as a kitchen Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use inÀammable gases near the unit Do not expose yourself directly to the cooling airÀow for many hours Do not...

Page 2: ...irÀow direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 6 Drain hose 7 Remote control signal receiver CAUTION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous Àuorescent...

Page 3: ...If the remote control range noticeably got shorten replace the batteries and press RESET button You can quickly start the operation with following 3 steps Remote Controller Overview and Operations 1 START STOP button 2 MODE button Switches operation mode in following order AUTO COOL DRY FAN HEAT Notes in HEAT mode At the beginning of the operation the indoor unit operates at very low fan speed for...

Page 4: ...n the unit is rotating at very low speed or stopping In FAN mode either of swing direction 1 l 3 or 4 l 7 is performed in accordance with the vertical airÀow direction previously set before you start the SWING operation Remote Controller Overview and Operations 10 SET button Adjusts the vertical airÀow direction See page 5 11 SLEEP timer button Activates the SLEEP timer that helps you to fall asle...

Page 5: ...d it could reduce the operating performance of the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate brieÀy maximum of 15 minutes OPERATION indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after th...

Page 6: ...ocks at the top of the panel a To latch each shaft properly insert the shaft until it snaps Then close the intake grille b a a b b 4 Press 4 places on the intake grille to close it completely Cleaning the air lters Mind that you have a periodical cleaning of the air lters to prevent reducing the operation ef ciency of the product Using of clogged air lter with dust will lower the product performan...

Page 7: ...amage 4 Rinse the lter well with water Àow 5 Dry the lter throughly in shaded place 6 Reinstall the ion deodorization lter to the indoor unit Replace the lter once every 3 years under normal use After extended non use of the unit If you have shut down the indoor unit for 1 month or more perform the FAN operation for half a day to dry the internal parts throughly before you perform normal operation...

Page 8: ...e automatic defrosting operation while the OPERATION indicator is Àashing 5 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET the fan rotates at very low speed and the airÀow is reduced In COOL mode the indoor unit fan may stop from time to time when the outdoor unit is stopped 3 When monitoring opera...