1
2016.10.26
SPECIFICATIONS
INDOOR UNIT
OUTDOOR UNIT
Capacity
POWER SUPPLY
Operating current
Operating current
Power consumption
Capacity
Power consumption
EER
Dehumidification
ASYG09KXCA
AOYG09KXCA
2.50 kW
COOLING
HEA
TING
3.60 kW
Single phase, 230 V, 50 Hz
2.8 A
2.1 A
14.0 A
Max operating current
Max operating current
8.5 A
0.460 kW
5.45 kW/kW
COP
0.630 kW
5.72 kW/kW
1.1 L/h
ASYG12KXCA
AOYG12KXCA
3.40 kW
5.00 kW
4.5 A
3.0 A
16.0 A
9.0 A
0.670 kW
5.09 kW/kW
1.020 kW
4.90 kW/kW
1.2 L/h
ELECTRICAL DATA
COMPRESSOR AND REFRIGERANT
AIR CIRCULATION
DIMENSIONS
TYPE
REFRIGERANT TYPE
Hermetic type, 6 pole,
2-cylinder rotary,
DC brushless motor
DISCRIMINATION
PRECHARGED REFRIGERANT
R32
WEIGHT (with oil)
10.0 kg
9RD138ZCA21
1,820 m3/h
1,975 m3/h
1,975 m3/h
2,230 m3/h
OUTDOOR UNIT Cooling
OUTDOOR UNIT Heating
INDOOR UNIT
H x W x D
H x W x D
OUTDOOR UNIT
WEIGHT
INDOOR UNIT Net / Shipping
Net / Shipping
20 kg / 24 kg
OUTDOOR UNIT
41 kg / 46 kg
293 x 786 x 378 mm
704 x 820 x 315 mm
NOISE LEVEL
High
46 dB
42 dB
38 dB
28 dB
41 dB
INDOOR UNIT
Cooling
High
670 m3/h
590 m3/h
520 m3/h
350 m3/h
Medium
Low
Quiet
INDOOR UNIT
FAN MOTOR AND REVOLUTION
High
610 rpm
660 rpm
660 rpm
740 rpm
MFD-W65XA2F
MFE-80DVL
1,310 rpm
1,160 rpm
1,050 rpm
780 rpm
Medium
Low
Quiet
OUTDOOR UNIT Cooling
OUTDOOR UNIT Heating
OUTDOOR UNIT Discrimination
INDOOR UNIT
Cooling
High
1,490 rpm
1,300 rpm
1,130 rpm
830 rpm
Medium
Low
Quiet
INDOOR UNIT
Heating
INDOOR UNIT Discrimination
Medium
Low
Quiet
High
48 dB
43 dB
39 dB
30 dB
INDOOR UNIT
Heating
Medium
Low
Quiet
OUTDOOR UNIT Heating
40 dB
43 dB
44 dB
OUTDOOR UNIT Cooling
1,300 g
15 m
10 m
MAXIMUM PIPING LENGTH
MAXIMUM PIPING HEIGHT DIFFERENCE