NOTES:
• The air conditioner custom code is set to prior to shipment.
• If you do not know the air conditioner custom code setting, try each of the custom codes ( →
→ → ) until you find the code that operates the air conditioner.
¢
Contents of function setting
Each function setting listed in this section is adjustable in accordance with the installation environ-
ment.
NOTE:
Setting will not be changed if invalid numbers or setting values are selected.
Function setting list
Function no.
Functions
1)
11
Filter sign
2)
30
Room temperature sensor control for cooling
3)
31
Room temperature sensor control for heating
4)
40
Auto restart
5)
42
Room temperature sensor switching
6)
44
Remote controller custom code
7)
46
External input control
8)
48
Room temperature sensor switching (Aux.)
9)
49
Indoor unit fan control for energy saving for cooling
1) Filter sign
Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated
amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
Function number
Setting value
Setting description
Factory setting
11
00
Standard (400 hours)
01
Long interval (1,000 hours)
02
Short interval (200 hours)
03
No indication
♦
2) Room temperature sensor control for cooling
Depending on the installed environment, correction of the room temperature sensor may be re-
quired. Select the appropriate control setting according to the installed environment.
Function number
Setting value
Setting description
Factory setting
30
00
Standard
♦
01
Slightly lower control
02
Lower control
03
Higher control
- 26 -
11-1. Function settings by using remote controller
11. Function settings
WALL MOUNTED
ASYG09-14KHCA
WALL MOUNTED
ASYG09-14KHCA