E R R O R C O N T E N T S
The OPERATION, TIMER and SWING lamps operate
as follows according to the error contents.
Error display
OPERATION
TIMER
SWING
(RED)
(GREEN)
(ORANGE)
Error contents
Indoor unit circuit board error
Indoor unit room temperature sensor wire opened
Indoor unit room temperature sensor wire short circuited
Indoor unit piping sensor wire opened
Indoor unit piping sensor short circuited
Outdoor unit Indoor unit communication error
Outdoor unit compressor temperature sensor error
Outdoor unit heat exchanger temperature sensor error
Outdoor unit outdoor temperature sensor error
2 times
2 times
3 times
3 times
5 times
Indoor unit fan error
6 times
5 times
8 times
Outdoor unit pressure switch error
Outdoor unit 2 way valve temperature sensor error
Outdoor unit 3 way valve temperature sensor error
9 times
Indoor unit fan connection capacity error
IPM error
10 times
Compressor loter location error
13 times
Outdoor fan motor error
14 times
Outdoor unit discharge temperature sensor error
5 times
3 times
4 times
3 times
2 times
4 times
:
Fast flashing
:
Slow flashing
:
Off
Indoor unit Outdoor unit communication error
12