REFRIGERANT SYSTEM DIAGRAM
Models : ASY14FSBCW / AOY14FSBC
Models : ASY14USBCW / AOY14USBC
Heating
Cooling
(with Charging valve)
Condenser
Dryer
(Flare connection)
Gas pipe (9.52 dia.)
(Flare connection)
(Flare connection)
Liquid pipe (6.35 dia.)
(Flare connection)
[ INDOOR UNIT ]
[ OUTDOOR UNIT ]
[ Connecting pipe ]
Com-
pressor
5
2004.08.17 preliminary
3-Way valve
4-Way
valve
Capillary tube
or heating and cooling
2-Way valve
Check
valve
C
ap
ill
ar
y
tu
be
fo
r
he
at
in
g
Evaporator
Summary of Contents for AOY14FSBC
Page 7: ...6 2004 08 17 preliminary CIRCUIT DIAGRAM Model ASY14FSBCW Model AOY14FSBC ...
Page 8: ...7 2004 08 17 preliminary Model ASY14USBCW Model AOY14USBC ...
Page 12: ...1 Indoor unit DISASSEMBLY ILLUSTRATION 11 2004 08 17 preliminary 4 1 3 3 2 1 51 ...
Page 14: ...Model AOY14FSBC 13 2004 08 17 preliminary ...
Page 20: ...0408G2649 ...