![Fujitsu AOY12LMAKL Service Manual Download Page 2](http://html.mh-extra.com/html/fujitsu/aoy12lmakl/aoy12lmakl_service-manual_2344169002.webp)
SPECIFICATIONS
TYPE
COOLING & HEATING
INDOOR UNIT
ARY12LUAD
ARY14LUAD
OUTDOOR UNIT
AOY12LMAKL
AOY14LMAKL
COOLING CAPACITY
3.50 kW
4.30 kW
HEATING CAPACITY
4.00 kW
4.80 kW
POWER SOURCE
230 V
FREQUENCY
50 Hz
RUNNING CURRENT
COOLING
5.10 A
6.00 A
HEATING
5.80 A
6.50 A
INPUT WATTS
COOLING
1.15 kW
1.37 kW
HEATING
1.32 kW
1.49 kW
E.E.R.
COOLING
3.04 kW/kW
3.14 kW/kW
HEATING
3.03 kW/kW
3.21 kW/kW
MOISTURE REMOVAL
Note : The above list shows values at the external static pressure of 0Pa, setting the fan speed high notch.
1.2 l/hr
1.5 l/hr
TYPE
Hermetic type, 4 poles, DC motor,
Twin Rotary
DISCRIMINATION
TNB220FPCM
REFRIGERANT
(R410A)
1,250 g
DISCRIMINATION
DISCRIMINATION
MFA-18NTT
MFA-18NTT
HIGH-SPEED
750 r.p.m.
1,000 r.p.m.
FAN SPEED
INDOOR
MED-SPEED
680 r.p.m.
860 r.p.m.
LOW-SPEED
610 r.p.m.
720 r.p.m.
OUTDOOR
HIGH-SPEED
LOW-SPEED
780 r.p.m.
MFB-24JTAT
400 r.p.m.
AIR FLOW
INDOOR
580 m
3
/h
780 m
3
/h
OUTDOOR
2,800 m
3
/h
DIMENSIONS
INDOOR
217 x 953 x 595 mm
H x W x D
OUTDOOR
650 x 830 x 320 mm
WEIGHT
INDOOR
29 / 25 kg
GROSS / NET
OUTDOOR
Note : The above list shows values at the external static pressure of 0Pa,setting the fan speed high notch.
58 / 54 kg
ELECTRICAL DATA
COMPRESSOR
FAN MOTOR
PIPE LENGTH
10 m
1,250 g
FULL CHARGE AMOUNT
15 m
1,350 g
20 m
1,450 g
25 m
1,550 g
MAXIMUM PIPE HEIGHT
When you dismantle indoor units which are installed, take care not to make parts fall down, especially motors.
15 m
ADDITIONAL REFRIGERANT
20 g / m
NOISE LEVEL
REFRIGERANT
HIGH-SPEED
32 dB
38 dB
INDOOR UNIT
MED-SPEED
COOL
HEAT
Note : Static pressure : 0Pa / Duct length : Inlet 0.5m, Outlet 1m
29 dB
34 dB
LOW-SPEED
27 dB
30 dB
OUTDOOR UNIT
52 dB
52 dB
50 dB
50 dB
1
2006.05.24