![Fujitsu AOWX18FAT Operating Manual Download Page 26](http://html.mh-extra.com/html/fujitsu/aowx18fat/aowx18fat_operating-manual_2344161026.webp)
En-7
To Stop Operation
Press the START/STOP button [Fig. 6 (6-9)].
The OPERATION Indicator Lamp (green) [Fig. 4 (4-1)] will go out.
About AUTO CHANGEOVER Operation
AUTO:
●
When AUTO CHANGEOVER operation fi rst selected, the fan will operate
at very low speed for 1 ~ 3 minute, during which time the unit detects
the room conditions and selects the proper operating mode.
If the difference between thermostat setting and actual room tempera-
ture is more than +2 °C
→
Cooling operation
If the difference between thermostat setting and actual room tempera-
ture is less than +2 °C
→
Dry operation
●
If the mode automatically selected by the unit is not what you wish,
select one of the mode operation (COOL, DRY, FAN).
About Mode Operation
Cooling:
●
Use to cool your room.
Dry:
●
Use for gently cooling while dehumidifying your room.
●
You cannot heat the room during Dry mode.
●
During Dry mode, the unit will operate at low speed; in order to adjust
room humidity, the indoor unit’s fan may stop from time to time. Also,
the fan may operate at very low speed when adjusting room humid-
ity.
●
The fan speed cannot be changed manually when Dry mode has been
selected.
Fan:
●
Use to circulate the air throughout your room.
During Cooling/Dry mode:
Set the thermostat to a temperature set-
ting that is lower than the current room
temperature. The Cooling and Dry modes
will not operate if the thermostat is set
higher than the actual room temperature
(in Cooling mode, the fan alone will
operate).
During Fan mode:
You can not use the unit to heat and cool
your room.
9385989054 EN.indd 7
9385989054 EN.indd 7
7/8/10 9:11:43 AM