background image

1. Precautions

When you start servicing, pay attention to the following points. For detailed precautions, refer to the

installation manual of the products.

CAUTION

• Service personnel

– Any person who is involved with working on or breaking into a refrigerant circuit should hold a

current valid certificate from an industry-accredited assessment authority, which authorizes

their competence to handle refrigerants safely in accordance with an industry recognized as-

sessment specification.

– Servicing shall only be performed as recommended by the equipment manufacturer. Mainte-

nance and repair requiring the assistance of other skilled personnel shall be carried out under

the supervision of the person competent in the use of flammable refrigerants.

– Servicing shall be performed only as recommended by the manufacturer.

• Work

– Work in confined spaces shall be avoided.
– The area around the workspace shall be sectioned off.
– Electric shock may occur. After turning off the power, always wait 5 minutes before touching

electrical components.

– Do not touch the fins of the heat exchanger. Touching the heat exchanger fins could result in

damage to the fins or personal injury such as skin rupture.

– Do not place any other electrical products or household belongings under the product.
– Condensation dripping from the product might get them wet, and may cause damage or mal-

function to the property.

• Service parts information and design are subject to change without notice for product improve-

ment.

• For the latest information of the service parts, refer to our Service Portal.

https://fujitsu-general.force.com/portal/

• Precise figure of the service parts listed in this manual may differ from the actual service parts.

- (02-1) -

1. Precautions

TEC

H

N

IC

A

D

A

TA

A

N

D

 PA

R

TS 

LI

ST

TEC

H

N

IC

A

D

A

TA

A

N

D

 PA

R

TS 

LI

ST

Summary of Contents for AOUH30LPAS1

Page 1: ...AIR CONDITIONER Wall mounted type SERVICE MANUAL INDOOR ASUH30LPAS ASUH36LPAS OUTDOOR AOUH30LPAS1 AOUH36LPAS1 SR_AS053EF_01 2021 12 03 ...

Page 2: ...please check with our authorized dealer Trademarks FGLair is trademark of Fujitsu General Limited in the United States other countries or both Google Play is trademark of Google Inc App Store is a service mark of Apple Inc registered in the U S and other countries Copyright 2021 Fujitsu General Limited All rights reserved ...

Page 3: ...CONTENTS 1 GENERAL INFORMATION 2 TECHNICAL DATA AND PARTS LIST ...

Page 4: ......

Page 5: ...1 GENERAL INFORMATION 2021 12 03 SR_CH01_AS053EF_01 ...

Page 6: ...CONTENTS 1 GENERAL INFORMATION 1 Specifications 01 1 1 1 Indoor unit 01 1 1 2 Outdoor unit 01 3 2 Dimensions 01 4 2 1 Indoor unit 01 4 2 2 Outdoor unit 01 6 ...

Page 7: ...M m3 h 812 1 380 812 1 380 MED 665 1 130 665 1 130 LOW 536 910 536 910 QUIET 418 710 418 710 Heating HIGH 812 1 380 812 1 380 MED 665 1 130 665 1 130 LOW 536 910 536 910 QUIET 418 710 418 710 Type Q ty Crossflow fan 1 Motor output W 78 Sound pressure level 3 Cooling HIGH dB A 50 50 MED 45 45 LOW 38 38 QUIET 32 32 Heating HIGH 49 49 MED 44 44 LOW 38 38 QUIET 32 32 Heat exchanger type Dimensions H W...

Page 8: ...B 15 FWB 9 44 CWB Pipe length 25 ft 7 5 m Height difference 0 ft 0 m Between outdoor unit and indoor unit Protective function might work when using it outside the operation range 2 Maximum current is maximum value when operated within the operation range 3 Sound pressure level Measured values in manufacturer s anechoic chamber Because of the surrounding sound environment the sound levels measured ...

Page 9: ...5 8 788 940 320 Gross 38 1 16 40 7 16 17 1 2 966 1 027 445 Weight Net lb kg 117 53 Gross 134 61 Connection pipe Size Liquid in mm Ø3 8 Ø9 52 Gas Ø5 8 Ø15 88 Method Flare Pre charge length ft m 66 20 Max length 164 50 Max height difference 98 30 Drain hose Material LDPE Tip diameter in mm Ø1 2 Ø13 0 I D Ø5 8 to 11 16 Ø16 0 to 16 7 O D Operation range Cooling F C 14 to 115 10 to 46 Heating 5 to 75 1...

Page 10: ...520 3 9 16 90 13 16 20 2 1 2 64 18 7 8 479 2 6 16 61 4 1 4 108 19 6 8 502 20 1 2 520 1 15 16 50 1 15 16 50 7 16 11 13 6 16 340 ø 8 0 ø 8 0 13 6 16 340 11 280 10 16 16 45 1 4 1 150 19 483 21 7 16 544 22 1 16 560 45 1 4 1 150 2 1 Indoor unit 01 4 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...

Page 11: ...he product Conden sation dripping from the product might get them wet and may cause damage or malfunction to the property 2 1 2 63 or more 3 8 1 80 or more 1 15 16 50 or more 1 15 16 50 or more 2 3 4 70 or more Outline of unit 5 1 2 140 or more 59 1 16 1 500 or more 70 7 8 1 800 or more Unit in mm 2 1 Indoor unit 01 5 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...

Page 12: ... 1 7 8 48 1 15 16 50 2 5 16 59 5 3 16 131 3 3 4 95 3 3 4 96 5 1 2 140 2 Ф7 8 22 Cable port 2 Ф7 8 22 Cable port 2 Ф1 8 28 Cable port 2 Ф1 8 28 Cable port Pipe port Pipe port 25 9 16 650 13 7 8 352 3 way valve Gas 3 way valve Liquid 1 1 4 48 Liquid A Detail A 5 5 8 143 5 13 16 147 2 3 16 55 Liquid 1 9 16 40 12 5 8 320 10 7 16 265 13 15 16 354 10 1 2 266 Liquid 11 5 8 296 Gas 2 1 2 64 Gas Rear view ...

Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2021 12 03 SR_CH02_AS053EF_01 ...

Page 14: ...Models AOUH30LPAS1 and AOUH36LPAS1 02 6 4 Accessories 02 10 4 1 Indoor unit 02 10 4 2 Outdoor unit 02 10 5 Refrigerant system diagrams 02 11 5 1 Models AOUH30LPAS1 and AOUH36LPAS1 02 11 6 Wiring diagrams 02 12 6 1 Indoor unit 02 12 6 2 Outdoor unit 02 13 7 PC board diagrams 02 14 7 1 Models ASUH30LPAS and ASUH36LPAS 02 14 7 2 Models AOUH30LPAS1 and AOUH36LPAS1 02 15 ...

Page 15: ...ommended by the manufacturer Work Work in confined spaces shall be avoided The area around the workspace shall be sectioned off Electric shock may occur After turning off the power always wait 5 minutes before touching electrical components Do not touch the fins of the heat exchanger Touching the heat exchanger fins could result in damage to the fins or personal injury such as skin rupture Do not ...

Page 16: ...st 2 1 Models ASUH30LPAS and ASUH36LPAS Exterior parts 1 a 8 8 7 13 3 4 5 6 12 11 11 11 11 2 10 9 2 1 Models ASUH30LPAS and ASUH36LPAS 02 2 2 Indoor unit parts list TECHNICAL DATA AND PARTS LIST TECHNICAL DATA AND PARTS LIST ...

Page 17: ... Wire cover assy 7 9315212016 Air clean filter assy 8 9386960007 Air filter 9 9334139011 Wireless remote controller 10 9334098004 Remote controller holder 11 9386986007 Screw cap 12 9387072211 Front panel total assy 13 9382114039 Intake grille assy a Front panel 2 1 Models ASUH30LPAS and ASUH36LPAS 02 3 2 Indoor unit parts list TECHNICAL DATA AND PARTS LIST TECHNICAL DATA AND PARTS LIST ...

Page 18: ... 59 50 69 68 a b c d e f 52 56 57 51 55 54 58 53 64 66 61 62 63 67 h 60 65 65 65 g 2 1 Models ASUH30LPAS and ASUH36LPAS 02 4 2 Indoor unit parts list TECHNICAL DATA AND PARTS LIST TECHNICAL DATA AND PARTS LIST ...

Page 19: ...756007 Drain hose insulation T 60 9387063004 Link holder assy 61 9900139186 Step motor 62 9387062007 Gear cover assy 63 9900384234 Step motor 64 9387060034 Casing assy 65 9318743012 Pipe bracket 66 9388540009 Drain hose assy 67 9316177017 Drain cap 68 9387055009 Crossflow fan assy 69 9306628017 Bearing C assy a Box shield assy b Control box c PCB holder A d Control cover e Motor cover f Motor cove...

Page 20: ...S1 and AOUH36LPAS1 Exterior parts and chassis 13 8 2 1 9 16 24 17 18 15 14 23 19 20 21 22 5 4 3 3 10 12 11 25 b a 7 6 3 1 Models AOUH30LPAS1 and AOUH36LPAS1 02 6 3 Outdoor unit parts list TECHNICAL DATA AND PARTS LIST TECHNICAL DATA AND PARTS LIST ...

Page 21: ...lem rear 19 9383863035 Front panel assy 20 9350680009 Fan guard assy 21 9383336003 Propeller fan 22 9603732011 DC fan motor 23 9383862007 Motor bracket assy 24 9383882005 Left panel sub assy 25 9374420711 Condenser sub assy 9711198006 Wire with connector P108 on Main PCB Terminal 9711203038 Wire with connector P660 on Main PCB P662 on Inverter PCB 9711204004 Wire with connector P661 on Main PCB P6...

Page 22: ...ssor 59 58 55 61 60 b 54 50 51 A A 52 53 a 56 57 62 B 63 65 64 65 64 65 64 66 B 3 1 Models AOUH30LPAS1 and AOUH36LPAS1 02 8 3 Outdoor unit parts list TECHNICAL DATA AND PARTS LIST TECHNICAL DATA AND PARTS LIST ...

Page 23: ...ant volume adjustment unit 58 9970209000 Expansion valve coil 59 9370947328 Expansion valve assy 60 9379079013 3 way valve assy 61 9377958037 3 way valve assy 62 9900985035 Thermistor Compressor temp 63 9810028006 Thermistor stopper 64 9379179096 Rubber washer G 65 9377973016 Special nut 66 9810666000 Compressor assy a Joint pipe D b Wiring fixation unit 3 1 Models AOUH30LPAS1 and AOUH36LPAS1 02 9...

Page 24: ...ook bracket 1 Tapping screw large 8 Remote controller 1 Tapping screw small 2 Battery 2 Air cleaning filters 1 Remote controller holder 1 Filter holder 2 4 2 Outdoor unit Models AOUH30LPAS1 and AOUH36LPAS1 Part name Exterior Q ty Part name Exterior Q ty Installation manual 1 Drain cap 3 Drain pipe 1 4 1 Indoor unit 02 10 4 Accessories TECHNICAL DATA AND PARTS LIST TECHNICAL DATA AND PARTS LIST ...

Page 25: ... Out temperature ThD ThO ThHO Thermistor Room temperature Thermistor Pipe temperature ThR ThPI Thermistor Heat Exchanger Med temperature ThHM ThHM Heat exchanger 3 way valve 3 way valve Pressure switch 4 way valve Strainer Strainer Expansion valve INDOOR Heat exchanger OUTDOOR Sub accumulator Compressor 5 1 Models AOUH30LPAS1 and AOUH36LPAS1 02 11 5 Refrigerant system diagrams TECHNICAL DATA AND P...

Page 26: ...6 Wiring diagrams 6 1 Indoor unit Models ASUH30LPAS and ASUH36LPAS 6 1 Indoor unit 02 12 6 Wiring diagrams TECHNICAL DATA AND PARTS LIST TECHNICAL DATA AND PARTS LIST ...

Page 27: ...6 2 Outdoor unit Models AOUH30LPAS1 and AOUH36LPAS1 6 2 Outdoor unit 02 13 6 Wiring diagrams TECHNICAL DATA AND PARTS LIST TECHNICAL DATA AND PARTS LIST ...

Page 28: ...9 B12B PASK 1 WHITE CN314 B3B XH AM WHITE CN313 B3B XH AM WHITE CN312 B2B XH AM WHITE CN311 B2B XH AM WHITE CN310 B2B XH AM WHITE COMMUNICATION PCB K14YM 1500HSE CA0 EX OUT1 EX OUT2 EX OUT3 EX IN1 EX IN2 FLASH AWG28 WHITE AWG28 WHITE AWG28 WHITE AWG28 WHITE AWG28 WHITE AWG28 WHITE AWG28 WHITE AWG28 WHITE AWG28 WHITE AWG28 WHITE 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 CN9 B10B PASK 1 WHITE CN200 ...

Page 29: ...30 AWG22 WHITE BLACK WHITE YELLOW BROWN RED DC FAN MOTOR FM HP SW1 HIGH PRESSURE SWITCH 1 EMI FILTER G ZCAT2132 1130 1 TURN COMPRESSOR COMP P400 U P401 V P402 W UL3271 AWG12 RED UL3271 AWG12 WHITE UL3271 AWG12 BLACK HEATSINK THERMISTOR UL3271 AWG14 RED FLASH P600 B128 PASK 1 WHITE DC13V 3 DC13V 3 D P660 B05B PASK 1 WHITE DC5V 3 C 5 4 3 2 1 DC13V 4 4 3 2 1 D P662 B05B PASK 1 WHITE P663 B04B PASK 1 ...