1-2. Outdoor unit
Type
Inverter heat pump
Model name
AOUH30LPAS1
AOUH36LPAS1
Power supply
208/230 V ~ 60 Hz
Power supply intake
Outdoor unit
Available voltage range
187—253 V
Starting current
A
13.4
17.8
Fan
Airflow rate
Cooling
CFM (m
3
/h)
2,187 (3,715)
2,187 (3,715)
Heating
2,187 (3,715)
2,187 (3,715)
Type × Q'ty
Propeller fan × 1
Motor output
W
100
Sound pressure level *1
Cooling
dB (A)
52
53
Heating
54
54
Heat exchanger type
Dimensions
(H × W × D)
in (mm)
Main 1: 29-3/4 × 35-5/8 × 11/16 (756 × 905 × 18.19)
Main 2: 29-3/4 × 35-5/8 × 11/16 (756 × 905 × 18.19)
Fin pitch
FPI
Main 1: 18 (1.45)
Main 2: 18 (1.45)
Rows × Stages
Main 1: 1 × 36
Main 2: 1 × 36
Pipe type
Copper
Fin type
Type (Material)
Aluminum
Surface treatment
Blue fin
Compressor
Type
DC twin rotary
Motor output
W
1,360
Refrigerant
Type
R410A
Charge
lb oz
4 lb 10 oz
4 lb 10 oz
g
2,100
2,100
Refrigerant oil
Type
POE (RB68)
Amount
in
3
(cm
3
)
48.8 (800)
Enclosure
Material
Steel sheet
Color
Beige
Approximate color of Munsell 10YR 7.5/1.0
Dimensions
(H × W × D)
Net
in (mm)
31 × 37 × 12-5/8 (788 × 940 × 320)
Gross
38-1/16 × 40-7/16 × 17-1/2 (966 × 1,027 × 445)
Weight
Net
lb (kg)
117 (53)
Gross
134 (61)
Connection pipe
Size
Liquid
in (mm)
Ø3/8 (Ø9.52)
Gas
Ø5/8 (Ø15.88)
Method
Flare
Pre-charge length
ft (m)
66 (20)
Max. length
164 (50)
Max. height difference
98 (30)
Drain hose
Material
LDPE
Tip diameter
in (mm)
Ø1/2 (Ø13.0) (I.D.), Ø5/8 to 11/16 (Ø16.0 to 16.7) (O.D.)
Operation range
Cooling
°F (°C)
14 to 115 (-10 to 46)
Heating
5 to 75 (-15 to 24)
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80 °FDB (26.67 °CDB) / 67 °FWB (19.44 °CWB), and outdoor temperature of 95 °FDB (35 °CDB) / 75 °FWB (23.9 °CWB).
– Heating: Indoor temperature of 70 °FDB (21.11 °CDB) / 59 °FWB (15 °CWB), and outdoor temperature of 47 °FDB (8.33 °CDB) / 43 °FWB (6.11 °CWB).
– Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
1-2. Outdoor unit
- (01-3) -
1. Specifications
G
EN
ER
A
L
IN
FO
R
MA
TI
O
N
G
EN
ER
A
L
IN
FO
R
MA
TI
O
N