3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢
Fan speed
Indoor fan speed is defined as below.
Operation mode
Fan mode
Speed (rpm)
ASUH18LPAS
ASUH24LPAS
Heating
POWERFUL
1,310
1,490
HIGH
1,210
1,390
MED+
1,130
1,320
MED
1,020
1,210
LOW
860
960
QUIET
700
810
Cool air prevention
580
680
S-LOW
540
540
Cooling/Fan
POWERFUL
1,360
1,590
HIGH
1,260
1,490
MED
1,140
1,140
LOW
960
960
QUIET
680
810
Soft quiet
580*
1
680*
1
S-LOW
540*
2
540*
2
Dry
X zone: 680
J zone: 640
X zone: 810
J zone: 760
*1: Fan mode only
*2: Cooling mode only
¢
Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
3-1. Indoor fan control
- (04-8) -
3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for AOUH18LPAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 10 12 SR_CH01_AS051EF_02 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2021 07 04 SR_CH02_AS051EF_01 ...
Page 33: ...3 TROUBLESHOOTING 2021 08 04 SR_CH03_AS051EF_01 ...
Page 36: ......
Page 95: ...4 CONTROL AND FUNCTIONS 2021 08 04 SR_CH04_AS051EF_01 ...
Page 129: ...5 FILED WORKING 2021 08 04 SR_CH05_AS051EF_01 ...