5-2. Outdoor unit
¢
Discharge temperature thermistor
Temperature °F (°C)
Resistance (kΩ)
Voltage (V)
-22.0 (-30.0)
1,013.11
0.06
-12.0 (-25.0)
729.09
0.09
-4.0 (-20.0)
531.56
0.12
5.0 (-15.0)
392.31
0.16
14.0 (-10.0)
292.91
0.21
23.0 (-5.0)
221.09
0.28
32.0 (0.0)
168.60
0.36
41.0 (5.0)
129.84
0.46
50.0 (10.0)
100.91
0.57
59.0 (15.0)
79.12
0.71
68.0 (20.0)
62.55
0.86
77.0 (25.0)
49.84
1.03
86.0 (30.0)
40.01
1.23
95.0 (35.0)
32.35
1.43
104.0 (40.0)
26.34
1.65
113.0 (45.0)
21.58
1.88
122.0 (50.0)
17.79
2.11
131.0 (55.0)
14.75
2.34
140.0 (60.0)
12.30
2.57
149.0 (65.0)
10.32
2.79
158.0 (70.0)
8.70
3.00
167.0 (75.0)
7.36
3.19
176.0 (80.0)
6.27
3.37
185.0 (85.0)
5.36
3.54
194.0 (90.0)
4.60
3.69
203.0 (95.0)
3.96
3.83
212.0 (100.0)
3.43
3.96
221.0 (105.0)
2.98
4.07
230.0 (110.0)
2.60
4.17
239.0 (115.0)
2.27
4.26
248.0 (120.0)
2.00
4.33