![Fujitsu AOU36RLXFZH Installation Manual Download Page 4](http://html.mh-extra.com/html/fujitsu/aou36rlxfzh/aou36rlxfzh_installation-manual_2344141004.webp)
En-3
2. 3. Accessories
WARNING
For installation purposes, be sure to use the parts supplied by the manufacturer or
other prescribed parts. The use of non-prescribed parts can cause serious accidents
such as the unit falling, water leakage, electric shock, or
fi
re.
Do not throw away the connecting parts until the installation has been complete.
Name and shape
Q’ty
Application
Installation
manual
1
(This book)
Drain cap
7
For outdoor unit drain
piping work
[45 type only]
Drain pipe
1
Adapter [in. (mm)]
K: [1/2 (12.70)
→
3/8 (9.52)] × 2
L: [1/2 (12.70)
→
5/8 (15.88)] × 2
H: [3/8 (9.52)
→
1/2 (12.70)] × 1
K
K
L
L
H
1 set
Adapter is necessary
in the connection of the
indoor unit.
For more information,
refer to the installation
manual included with the
indoor unit.
[45 type]
Adapter [in. (mm)]
K: [1/2 (12.70)
→
3/8 (9.52)] × 1
L: [1/2 (12.70)
→
5/8 (15.88)] × 1
H: [3/8 (9.52)
→
1/2 (12.70)] × 1
K
L
H
1 set
Adapter is necessary
in the connection of the
indoor unit.
For more information,
refer to the installation
manual included with the
indoor unit.
[36 type]
Cable tie with clip
Large: 2
For binding wire with
connector
(For conduit plate)
Small: 2
For binding wire with
connector
Cable tie
1
For binding wire with
connector
2. 4. System con
fi
guration
Layout example for the indoor units and outdoor unit
Valve cover removal
· Remove the six mounting screws.
· Remove the valve coner.
2. 4. 1. Connectable indoor unit capacity type (Outdoor unit: 45 type)
A
B
C
D
E
H1
H1
H2
Power source
208/230 V ~ 60 Hz
Power supply
cable
Connection
cable
Refrigerant pipe
OUTDOOR UNIT
INDOOR UNITS
UNIT E
7-9
UNIT D
7-12
UNIT C
7-18
UNIT B
7-24
UNIT A
7-24
CAUTION
The total capacity of the indoor units connected must be between 34,000 and 54,000
BTU.
Connection patterns are restricted. Normal operation is not guaranteed if connected
pattern in the combination not listed below. The product may be damaged. Surely con-
nect in accordance with the combination in the following connection pattern.
• To install an indoor unit, refer to the installation manual included with the indoor unit.
Indoor unit connection pattern
Indoor unit
A
B
C
D
E
1
24,000 24,000
―
―
―
2
24,000 18,000
―
―
―
3
18,000 18,000
―
―
―
4
24,000 18,000 12,000
―
―
5
24,000 18,000 9,000
―
―
6
24,000 18,000 7,000
―
―
7
24,000 15,000
15,000
―
―
8
24,000 15,000
12,000
―
―
9
24,000 15,000
9,000
―
―
10
24,000 15,000
7,000
―
―
11
24,000 12,000
12,000
―
―
12
24,000 12,000
9,000
―
―
13
24,000 12,000
7,000
―
―
14
24,000 9,000
9,000
―
―
15
24,000 9,000
7,000
―
―
16
24,000 7,000
7,000
―
―
17
18,000
18,000
18,000
―
―
18
18,000
18,000
15,000
―
―
19
18,000
18,000
12,000
―
―
20
18,000
18,000
9,000
―
―
21
18,000
18,000
7,000
―
―
22
18,000
15,000
15,000
―
―
23
18,000
15,000
12,000
―
―
24
18,000
15,000
9,000
―
―
25
18,000
15,000
7,000
―
―
26
18,000
12,000
12,000
―
―
27
18,000
12,000
9,000
―
―
28
18,000
12,000
7,000
―
―
29
18,000
9,000
9,000
―
―
30
18,000
9,000
7,000
―
―
31
15,000
15,000
15,000
―
―
32
15,000
15,000
12,000
―
―
33
15,000
15,000
9,000
―
―
34
15,000
15,000
7,000
―
―
35
15,000
12,000
12,000
―
―
36
15,000
12,000
9,000
―
―
37
12,000
12,000
12,000
―
―
38
24,000
15,000
7,000
7,000
―
39
24,000
12,000
9,000
9,000
―
40
24,000
12,000
9,000
7,000
―
41
24,000 12,000 7,000 7,000
―
42
24,000
9,000
9,000
9,000
―
43
24,000
9,000
9,000
7,000
―
44
24,000 9,000 7,000 7,000
―
45
24,000 7,000 7,000 7,000
―
9380545101-02_IM.indb 3
9380545101-02_IM.indb 3
2/26/2016 10:16:03 AM
2/26/2016 10:16:03 AM