- (02 - 01) -
O
U
TD
O
O
R U
N
IT
A
O
U
9-
12
R
L2
O
U
TD
O
O
R U
N
IT
A
O
U
9-
12
R
L2
SPECIFICATIONS
1.
Type
INVERTER HEAT PUMP
Model name
AOU9RL2
AOU12RL2
Power sourse
115V~ 60Hz
Available voltage range
103.5 - 126.5V~ 60Hz
Starting current
A
7.5
11.0
Fan
Airflow rate
Cooling
CFM
(m
3
/h)
1013 (1720)
1078 (1830)
Heating
889 (1510)
942 (1600)
Type × Q'ty
Propeller fan × 1
Motor output
W
23
23
Sound pressure level
Cooling
dB (A)
47
51
Heating
48
51
Heat exchanger type
Dimensions
(H × W × D)
in.
19-27/32 × 25-19/32 × 23/32
19-27/32 × 24-3/32 × 23/32
19-27/32 × 25-9/32 × 23/32
mm
504 × 650 × 18.2
504 × 612 × 18.2
504 × 642 × 18.2
FPI
19
18
Rows × Stages
1 × 24
2 × 24
Pipe type
Copper
Fin Type
Aluminum
Compressor
Type × Q'ty
Rotary × 1
Motor output
W
700
Refrigerant
Type
R410A
Charge
lbs.oz.
1lbs. 7oz.
1lbs. 12oz.
kg
650
800
Refrigerant oil
Type
VG74
Enclosure
Material
Steel
Color
Beige
Approximate color of MUNSELL 10YR7.5/1.0
Dimensions
(H × W × D)
Net
mm
540 × 660 × 290
inch
21-1/4 × 26 × 11-11/32
Gross
mm
611 × 797 × 401
inch
24-1/16 × 31-3/8 × 15-25/32
Weight
Net
lbs.
(kg)
64 (29)
69 (31)
Gross
69 (31)
73 (33)
Connenction
pipe
Size
Liquid
in.
(mm)
Ø1/4 (Ø6.35)
Gas
Ø3/8 (Ø9.52)
Method
Flare
Pre - charge length
ft.
(m)
49 (15)
Max. length
66 (20)
Max. height difference
49 (15)
Operation range
Cooling
°F
(°C)
15 to 115 (-10 to 46)
Heating
15 to 75 (-10 to 24)
Note:
Specifications are based on the following conditions.
Cooling:Indoor temperature of 80°F(26.67°C)DB/67°F(19.44°C)WB,and outdoor temperature of 95°F(35°C)DB/75°F(23.9°C)WB.
Heating:Indoor temperature of 70°F(21.11°C)DB/59°F(15°C)WB,and outdoor temperature of 47°F(8.33°C)DB/43°F(6.11°C)WB.
Pipe length:24ft.7in(7.5m),Height difference:0 m.(Outdoor unit-Indoor unit)