background image

SLEEP TIMER OPERATION

Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.

To Use the SLEEP timer

While the air conditioner is operating or stopped, press the
SLEEP button (Fig. 6 

J

).

The SLEEP TIMER mark ( 

 ) on the remote control unit’s display will light.

Within 3 seconds after ( 

 ) light the time can be changed by pressing SLEEP

button once again.
Each time the button is presssd, the time changes in the following order:

About three seconds later, the entire display will reappear.
The Indoor Unit’s OPERATION Indicator Lamp (red) (Fig. 3 

5

) and the TIMER indica-

tor lamp (green) (Fig. 3 

6

) light.

To Change the Timer Settings

Press the SLEEP button once to display the last setting time.
Press the SLEEP button again to change the time.

Each time the button is pressed, the time changes in the following order (Change
from the last setting time):

To Cancel the Timer:

Press the CANCEL TIMER button.

To Stop the Air Conditioner During
Timer Operation:

Press the START/STOP button.

About the SLEEP timer

To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modifies the thermostat set-
ting in accordance with the time setting. When the time has elapsed, the air conditioner completely stops.

During Cooling/Dry operation:

When the SLEEP timer is set, the thermostat setting is auto-
matically raised 1 °C every sixty minutes. When the ther-
mostat has been raised a total of 2 °C, the thermostat set-
ting at that time is maintained until the set time has elapsed,
at which time the air conditioner automatically turns off.

SLEEP timer setting

2°C

3°C

4°C

30
minutes

1°C

1 hour

1 hour
30 minutes

Set time

Set time

1 hour

1 °C

2 °C

During Heating operation:

When the SLEEP timer is set, the thermostat setting is
automatically lowered 1°C every thirty minutes. When the ther-
mostat has been lowered a total of 4°C, the thermostat setting
at that time is maintained until the set time has elapsed, at which
time the air conditioner automatically turns off.

SLEEP timer setting

Confirmation of TIMER's time

To confirm each TIMER's time, press SET button while setting OFF TIMER, ON TIMER or SLEEP TIMER (or during running).
If SET button is pressed, it will be changed into time display from temperature setting display. The left time of the TIMER
which is being set currently will be displayed for 5 seconds, then it will return to temperature setting display.

→   

1.0

   2.0

   3.0

   5.0

   7.0

    9.0(hour)

(RESET)

→   

1.0

   →   

2.0

  →   

3.0

   →  

 5.0

    →   

7.0

    →    

9.0(hour)

(RESET)

9

Summary of Contents for AOT12RSJC

Page 1: ...L REVERSE CYCLE ROOM AIR CONDITIONER WALL MOUNTED TYPE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A and Polyol Ester oil THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this p...

Page 2: ...purpose tools and specified cord are required Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner...

Page 3: ... con trol of air conditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE INTAKE GRILLE The indoor unit s Intake Grille can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easi...

Page 4: ... 9 0 3 1 4 5 6 8 2 7 OPERATION TIMER SWING ª ºŸ _ Fig 5 Fig 1 Fig 2 Fig 3 Fig 4 Fig 7 This figure shows the control display when all indicator lamps are on It may differ from the actual display Fig 6 3 ...

Page 5: ...on Q CANCEL TIMER button R FAN CONTROL button S START STOP button T AIR FLOW DIRECTION button U SWING LOUVER button V ACL button W TEST RUN button This button is used when installing the conditioner and should not be used un der normal conditions as it will cause the air conditioner s thermostat function to op erate incorrectly If this button is pressed during normal op eration the unit will switc...

Page 6: ... of a ballpoint pen or other small object Turn on the Power 1 Connect the Power Supply Plug Fig 1 C to an electri cal outlet in the case of a direct line connection turn on the circuit breaker Load Batteries R03 LR03 2 1 Press and slide the battery compartment lid on the re verse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the bat...

Page 7: ... the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 R Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the tempera ture of the...

Page 8: ...at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to...

Page 9: ...time while the ONTIMER mark on the remote control unit s display is flashing The flashing will continue for about 30 seconds 3 Press SET button Fig 6 P to select ON TIMER opera tion The ONTimer mark will be shown on the remote control unit s dis play The Indoor UnitTimer Indicator Lamp green Will light It can not be used during OFF TIMER operation To Cancel the Timer Press the CANCEL TIMER button ...

Page 10: ...es the thermostat set ting in accordance with the time setting When the time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the ther mostat has been raised a total of 2 C the thermostat set ting at that time is maintained until the set time has elapsed at which ti...

Page 11: ...vers are left in the heat ing range for more than 30 minutes they will automatically return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION button Fig 6 T Each time the button is pressed the air direction range w...

Page 12: ... range for more than 30 minutes the unit will automatically switch the swing range to the horizontal flow range to prevent the condensation of moisture on the outlet MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 on the main unit control panel To stop op...

Page 13: ...ir holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the Air Filter either with a vacuum cleaner or by washing the filter in a solution of mild detergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before reinstalling If dirt is allowed to acc...

Page 14: ...r resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop ...

Page 15: ...ndicator lamp red will flash Heating Performance This air conditioner operates on the heat pump princi ple absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind o...

Page 16: ...o prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humi...

Reviews: