Fujitsu AOBR24LFL Operating Manual Download Page 11

En-10

ADJUSTING THE DIRECTION OF AIR CIRCULATION

 

 Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Controller.

  Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the air

fl

 ow-direction louvers have stopped mov-

ing.

 DANGER!

 Never place 

fi

 ngers or foreign objects inside 

the outlet ports, since the internal fan oper-
ates at high speed and could cause personal 
injury.

  Always use the Remote Controller’s 

SET button to adjust the vertical air

fl

 ow 

louvers. Attempting to move them manu-
ally could result in improper operation; in 
this case, stop operation and restart. The 
louvers should begin to operate properly 
again.

  During use of the Cooling and Dry modes, 

do not set the Air Flow Direction Louvers 
in the Heating range (

4

 - 

6

) for long 

periods of time, since water vapor may 
condense near the outlet louvers and 
drops of water may drip from the air 
conditioner. During the Cooling and Dry 
modes, if the Air Flow Direction Louvers 
are left in the heating range for more than 
30 minutes, they will automatically return 
to position 

3

.

  When used in a room with infants, 

children, elderly or sick persons, the air 
direction and room temperature should 
be considered carefully when making 
settings.

Vertical Air Direction Adjustment

Press the SET button (Vertical) (Fig. 6 

S

).

Each time the button is pressed, the air direction range will change as follows:

 

1

 

 

2

 

 

3

 

 

4

 

 

5

 

 

6

Types of Air 

fl

 ow Direction Setting:

1

,

2

,

3

 :  During Cooling/Dry modes

4

,

5

,

6

 :  During Heating mode

The Remote Controller’s display does 
not change.

  Use the air direction adjustments within the ranges shown above.

  The vertical air

fl

 ow direction is set automatically as shown, in accordance with the type 

of operation selected.
  During Cooling/Dry mode 

:  Horizontal 

fl

 ow 

1

  During Heating mode 

:  Downward 

fl

 ow 

5

  During AUTO mode operation, for the 

fi

 rst minute after beginning operation, air

fl

 ow will 

be horizontal 

1

; the air direction cannot be adjusted during this period.

 Direction 

1

2

  Only the direction of the Air Flow Direction Louver changes; the direction of the Power 

Diffuser does not change.

1
2

3
4
5
6

Horizontal Air Direction Adjustment

Press the SET button (Horizontal)(Fig. 6 

T

).

  Each time the button is pressed, the air direction range will change as follows:

1

 

 

2

 

 

3

 

 

4

 

 

5

1

2

3

4

5

The remote controller’s display 
does not change.

9315345318-03_OM.indb   10

9315345318-03_OM.indb   10

2/26/2013   11:12:56 AM

2/26/2013   11:12:56 AM

Summary of Contents for AOBR24LFL

Page 1: ...YCLE KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE GUARDE ESTE MANUAL DE USO PARA FUTURAS CONSULTAS GUARDE ESTE MANUAL DE FUNCIONANENTO PARA REFERÊNCIA FUTURA FUJITSU GENERAL LIMITED P N9315345318 03 OPERATING MANUAL MANUAL DE FUNCIONAMIENTO MANUAL DE INSTRUÇÕES 9315345318 03_OM indb 1 9315345318 03_OM indb 1 2 26 2013 11 12 37 AM 2 26 2013 11 12 37 AM ...

Page 2: ... water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Connection valves become hot during Heating handle with care Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any electronic equipment is at le...

Page 3: ...on swing Since UP DOWN air direction flaps operate automatically according to the operating mode of the unit it is possible to set air direction based on the operating mode REMOVABLE OPEN PANEL The indoor unit s Open Panel can be removed for easy cleaning and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care SUPER ...

Page 4: ... Fig 5 Fig 1 Fig 2 Fig 3 Fig 4 Fig 7 To facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actral operation however the display will only show those indicators appropriate to the current operation Fig 6 24L 30L 9315345318 03_OM indb 3 9315345318 03_OM indb 3 2 26 2013 11 12 54 AM 2 26 2013 11 12 54 AM ...

Page 5: ...mperature SET Display b COIL DRY Display c SLEEP Display d SWING Display NAME OF PARTS Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced cooling...

Page 6: ...l is properly received by the air conditioner a beeping sound will be heard If no beep is heard press the Remote Controller button again Remote Controller Holder PREPARATION CAUTION Take care to prevent infants from acciden tally swallowing batteries When not using the Remote Controller for an extended period remove the batteries to avoid possible leakage and damage to the unit If leaking battery ...

Page 7: ...n Speed Press the FAN CONTROL button Fig 6 Q Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Coo...

Page 8: ...selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the OPERATION Indicator Lamp Fig 3 5 ...

Page 9: ...The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the arrow in the Remote Controller s Display OFF ON or OFF ON One example of Program timer use might be to have the air conditioner automatically s...

Page 10: ...EEP timer is set the thermostat setting is automati cally raised 1 C every sixty minutes When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During Heating operation When the SLEEP timer is set the thermostat setting is automatically lowered ...

Page 11: ...ith infants children elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 6 S Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Direction Setting 1 2 3 During Cooling Dry modes 4 5 6 During Heating mode The Remo...

Page 12: ... it has no sterilization effect either Begin air conditioner operation before performing this procedure Up down swing operation Left right swing operation Swing operation stops Up down left right swing operation About Swing Operation Up down swing Swing operation begins using the following range according to the current airflow direction Airflow direction is 1 4 for cooling dry With the upper airf...

Page 13: ...dle disconnect the two lower tabs and pull out Air filter handle Hooks two places 2 Remove dust with a vacuum cleaner or by washing After washing allow to dry thoroughly in a shaded place CAUTION To avoid excessive wear of the part and components or malfunctioning of the air conditioning the user consumer shall perform preventive maintenance through an accredited technical assistance periodically ...

Page 14: ...aning filter set 2 Engage the latch at both ends of the filter with the two hooks at the rear of the air cleaning filter frame Take care that the air cleaning filter does not project beyond the frame 3 Engage the four fixing locations at the top and bottom of the air cleaning filter frame with the hooks of the air filter 3 Install the two Air filters and close the Intake Grille When air cleaning f...

Page 15: ...emitted During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation 15 In regard to the Air Cleani...

Page 16: ... a power failure Has a fuse blown out or a circuit breaker been tripped Is the timer operating 8 9 Poor Cooling performance Is the Air Filter dirty Air the air conditioner s intake grille or outlet port blocked Did you adjust the room temperature settings thermostat correctly Is there a window or door open In the case of Cooling operation is a window allowing bright sunlight to enter Close the cur...

Page 17: ...00 27 000 POWER INPUT kW 2 16 2 44 CURRENT MAX A 9 9 13 5 11 2 17 0 ENERGY EFFICIENCY RATIO kW kW 3 26 3 24 AIRFLOW INDOOR UNIT m3 h 1 100 1 100 OUTDOOR UNIT m3 h 2 470 3 600 HEATING CAPACITY kW 7 91 9 08 BTU h 27 000 31 000 POWER INPUT kW 2 31 2 77 CURRENT MAX A 10 6 18 5 12 7 19 0 ENERGY EFFICIENCY RATIO kW kW 3 42 3 28 AIRFLOW INDOOR UNIT m3 h 1 120 1 150 OUTDOOR UNIT m3 h 2 570 3 600 MAX PRESS...

Page 18: ...9315345318 03_OM indb 17 9315345318 03_OM indb 17 2 26 2013 11 13 03 AM 2 26 2013 11 13 03 AM ...

Page 19: ...9315345318 03_OM indb 18 9315345318 03_OM indb 18 2 26 2013 11 13 03 AM 2 26 2013 11 13 03 AM ...

Page 20: ...9315345318 03_OM indb 2 9315345318 03_OM indb 2 2 26 2013 11 12 54 AM 2 26 2013 11 12 54 AM ...

Reviews: