SAFETY DEVICES
10.
Protection form
Model
AO
G09LTCN
AO
G12LTCN
AO
G14LTCN
Circuit protection
Current fuse
(Near the terminal)
250V 20A
250V 5A
─
Current fuse
(Main printed circuit board)
250V 15A
250V 5A
250V 3.15A
250V 3.15A
Fan motor protection
Thermal protection
program
OFF : 150±15°C
ON : 120±15°C
OFF : 100±15°C
ON : 95±10°C
Compressor protection
Thermal protection
program
(Discharge temp.)
OFF : 110°C
ON : After 7 minutes
Heater protection
Current fuse
250V 5A (2pcs)
250V 5A (1pc)
Thermal protection switch
(Heater temp.)
OFF: 55
+3
-3
°C
ON: 45
+4
-4
°C