DIMENSIONS
2.
MODEL
: AO
G09LTCN
(Unit : mm)
INSTALLATION PLACE
600 mm or more
100 mm or more
200 mm or more
100 mm or more
250 mm or more
(Service space)
CAUTION
In areas with heavy snowfall, if the intake and outlet
of the outdoor unit is blocked with snow, it may be dif-
ficult to warm up and likely to cause breakdown. In such
condition, be sure to construct a canopy or baffle board
stand.
If the space is larger than stated, the condition will be the same as those without any obstacles.
790
290
352
68
20
10
18
Top view
209
Side view
Front view
175
110
9
20
540
320
4-ø11.3mm hole
540
Air flow
ø20 hole
Bottom view
(6x20=120)
(6x20=120)
25 23
25
23
55 55
(10)
(10)
(10)
20
20
hole
17.5
25
10
10
hole
102