background image

En-1

SAFETY PRECAUTIONS

 

● Before using the appliance, read these “PRECAUTIONS” thoroughly 

and operate in the correct way.

 

● The instructions in this section all relate to safety; be sure to maintain 

safe operating conditions.

 

● “WARNING” and “CAUTION” have the following meanings in these 

instructions:

 WARNING

This mark indicates procedures which, if im-
properly performed, might lead to the death or 
serious injury of the user.

 CAUTION

This mark indicates procedures which, if im-
properly performed, might possibly result in per-
sonal harm to the user, or damage to property.

PRECAUTIONS ON USE

 WARNING

 

● Do not keep exposing oneself to the direct wind of air conditioner for a 

long time.

 

● Do not insert fi ngers or objects into the outlet port or intake grilles.

 

● Except for EMERGENCY, never turn off  main as well as sub breaker 

of the indoor units during operation. It will cause compressor failure as 
well as water leakage. First, stop the indoor unit by operating the con-
trol unit, converter or external input device and then cut the breaker. 
Make sure to operate through the control unit, converter or external 
input device.

 

● If the power supply cord of this appliance is damaged, it should only 

be replaced by the authorized service personal, since special purpose 
tools and specifi ed cord are required.

 

● If any refrigerant happens to leak, extinguish any fl ames, ventilate the 

room and get in touch with authorized service personnel.

 CAUTION

 

● Do not place animals or plants in the direct path of the airfl ow.

 

● Do not direct airfl ow at fi replaces or heating apparatus.

 

● Do not block or cover the inlet port and outlet port.

 

● Do not climb on, or place objects on, the air conditioner.

 

● Do not set fl ower vases or water containers on top of air conditioners.

 

● Do not hang objects from the indoor unit.

 

● Do not place anything below the indoor unit that should not get wet.

 

● Always turn off  the electrical breaker whenever cleaning the air condi-

tioner or the air fi lter.

 

● Do not pour water or cleaning solvent on the unit directly, or wash the 

unit with them.

 

● Do not expose the air conditioner directly to water.

 

● Do not operate the air conditioner with wet hands.

 

● Check the condition of the installation stand for damage.

 

● Operate only with air fi lters installed.

 

● Do not drink the water drained from the air conditioner.

 

● Do not apply any heavy pressure to radiator fi ns.

 

● Do not use fl ammable gases near the air conditioner.

 

● Do not touch the piping during operation.

 

● Ensure that any electronic equipment is at least 40 in (1 m) away from 

either the indoor or outdoor units.

 

● This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of ex-
perience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for 
their safety. Children should be supervised to ensure that they do not 
play with the appliance.

Note:

  Switching the operating mode in the heat recovery system may 

require some time to prepare for operation. Please note that this is 
not a fault.

PRECAUTIONS ON INSTALLATION

 CAUTION

 

● Do not attempt to install this air conditioner by yourself.

 

● This unit contains no user-serviceable parts. Always consult authorized 

service personnel for repairs.

 

● When moving, consult authorized service personnel for disconnection 

and installation of the unit.

 

● The unit must be earthed (grounded).

 

● Make sure drain work is implemented properly for drainage.

 

● Avoid installing the air conditioner near a fi replace or other heating 

apparatus.

 

● When installing the indoor and outdoor units, take precautions to pre-

vent access by infants.

NAME OF PARTS

1

2

1

 Outlet Port

2

 Intake Port

Control unit (optional)

Types of remote controllers:
●  Wireless remote controller
  (Be sure to use after connecting receiver unit.)
●  Wired remote controller
●  Simple remote controller
For operation method, please refer to the Operating Manual of each 
device.

OPERATING MANUAL

PART No. 9374343454
VRF system indoor unit (Duct type)

CONTENTS

SAFETY PRECAUTIONS ....................................................................... 1
NAME OF PARTS .................................................................................. 1
MANUAL AUTO OPERATION ............................................................... 2
OPERATING TIPS ................................................................................. 2
CLEANING AND CARE.......................................................................... 3
TROUBLESHOOTING ........................................................................... 3
SPECIFICATIONS .................................................................................. 4

9374343454-01_OM.indb   1

9374343454-01_OM.indb   1

2019/8/30   10:15:30

2019/8/30   10:15:30

Summary of Contents for Airstage ARUM24TLAV2

Page 1: ...reference Français Español MODE D EMPLOI MANUAL DE FUNCIONAMIENTO UNITÉ INTÉRIEURE type conduit UNIDAD INTERIOR Tipo conducto Conservez ce manuel pour pour toute référence ultérieure Conserve este manual para posibles consultas futuras 9374343454 01_OM indb cover1 9374343454 01_OM indb cover1 2019 8 30 10 15 30 2019 8 30 10 15 30 ...

Page 2: ...e unit with them Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Check the condition of the installation stand for damage Operate only with air filters installed Do not drink the water drained from the air conditioner Do not apply any heavy pressure to radiator fins Do not use flammable gases near the air conditioner Do not touch the piping during...

Page 3: ...y state activates when 2 or more indoor units start up at the same time in different mode Any indoor unit other than priority mode will wait in standby state until priority mode changes operation starts as soon as priority is switched At this time the OPERATION indicator lamp green lights up and the TIMER indicator lamp orange flashes limited to only when receiver unit is con nected Low ambient cool...

Page 4: ... stop If you wish to warm the room further set the thermostat for a higher setting During oil recovery operation the airflow may stop for approximately 10 minutes See page 2 During Heating operation the unit will temporarily stop operation be tween 4 and 15 minutes as the Automatic Defrosting mode operates See page 2 The fan may operate at low speed during Dry operation or when the unit is monitori...

Page 5: ...m cannot be solved even when the troubleshooting checks have been performed The FILTER indicator lamp red is flashing very fast when receiver unit is connected The wired remote controller or simple remote controller indicate Er when connected It has burning smell For details on marking the Flashing lamps please refer to the Manual of IR Receiver Unit or Wired Remote Controller SPECIFICATIONS MODEL ...

Page 6: ...9374343454 01_OM indb 5 9374343454 01_OM indb 5 2019 8 30 10 15 31 2019 8 30 10 15 31 ...

Reviews: