background image

En-5

TROUBLESHOOTING

The following conditions are not breakdowns or operation failures.

Symptom

Problem

See page

Doesn’t operate immediately:

If the unit is stopped and then immediately started again, the compressor will not operate for about 

 

3 minutes, in order to prevent fuse blowouts.

Whenever the electrical breaker is turned off then on again, the protection circuit will operate for 

 

about 3 minutes, preventing unit operation during that period.

Air

fl

 ow is weak or stops:

When Heating operation is started, indoor unit’s fan may temporarily stop, to allow internal parts to 

 

warm up.

During Heating operation, if the room temperature rises above the thermostat setting, the outdoor 

 

unit will stop, and the indoor unit’s fan will stop. If you wish to warm the room further, set the 
thermostat for a higher setting.

During oil recovery operation, the air 

fl

 ow may stop for approximately 10 minutes.

 

3

During Heating operation, the unit will temporarily stop operation (between 4 and 15 minutes) as 

 

the Automatic Defrosting mode operates.

3

The fan may operate at low speed during Dry operation or when the unit is monitoring the room’s 

 

temperature.

In the monitor AUTO operation, the fan will operate at low speed.

 

Flashing lamps:

The OPERATION indicator lamp
(green) 

fl

 ashes:

An oil recovery operation is being performed.

3

The OPERATION indicator lamp
(green) 

fl

 ashes:

An automatic defrosting operation is being per formed.

3

The OPERATION indicator lamp
(green) and TIMER indicator lamp
(orange) are 

fl

 ashing alternately:

It has recovered from a power outage.

The OPERATION indicator lamp
(green) and TIMER indicator lamp
(orange) are 

fl

 ashing 

simultaneously:

It is operating in trial operation mode.
Ask a manager as there may be maintenance being conducted.

The OPERATION indicator lamp 
(green) lights up and the TIMER
indicator lamp (orange) 

fl

 ashes:

This is the standby state.

3

Noise is heard:

In the following conditions there are sounds of water 

fl

 owing from the indoor unit and the operation 

 

sound becomes loud. These are the sounds of the 

fl

 owing of refrigerant.

When operation starts 
When oil recovery operation 

fi

 nishes 

When automatic defrosting operation 

fi

 nishes

During operation, a slight squeaking sound may be heard. This is the result of minute expansion 

 

and contraction of the panel due to temperature changes.

During Heating operation, a sizzling sound may be heard occasionally. This sound is produced by 

 

the Automatic Defrosting operation.

3

Smells:

Some smell may be emitted from the indoor unit. This smell is the result of room smells (furniture, 

 

tobacco, etc.) which have been taken into the air conditioner.

Fog comes out of the indoor unit:

During Cooling operation, a thin mist may be seen emitted from the indoor unit. This results from 

 

the sudden Cooling of room air by the air emitted from the air conditioner, resulting in condensation 
and misting.

Steam comes out of the indoor 
unit:

During Heating operation, the outdoor unit’s fan may stop, and steam may be seen rising from the 

 

unit. This is due to the Automatic Defrosting operation.

3

Water is produced from the 
outdoor unit:

During Heating operation, water may be produced from the outdoor unit due to the Automatic 

 

Defrosting operation.

The following conditions may not be breakdowns so check again.

Symptom

Items to check

See page

Doesn’t operate at all:

Has there been a power failure?

 

Has a fuse blown out, or a circuit breaker been tripped?

 

Is the main power switch set to the OFF position?

 

Are you trying to engage in an operation different from the priority state?

 

3

Is it in standby state?

 

3

The operation mode cannot be 
changed:

Are you trying to change to an operation different from the priority conditions?

 

3

9369308086-01_OM.indb   5

9369308086-01_OM.indb   5

2012-6-15   8:58:13

2012-6-15   8:58:13

Summary of Contents for AIRSTAGE ABHA12GATH

Page 1: ...nce ultérieure Conserve este manual para posibles consultas futuras Italiano MANUALE DI ISTRUZIONI UNITÀ INTERNA tipo a pavimento soffitto tipo a soffitto Conservare questo manuale per consultazione futura Ελληνικά Português ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Τύπου Δαπέδου Οροφής Τύπου οροφής Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά MANUAL DE FUNCIONAMENTO UNIDADE INTERIOR Modelo...

Page 2: ...ir conditioner or the air filter Do not pour water or cleaning solvent on the unit directly or wash the unit with them Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Check the condition of the installation stand for damage Operate only with air filters installed Do not drink the water drained from the air conditioner Do not apply any heavy pre...

Page 3: ...ce MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the remote control unit is lost or otherwise unavailable CAUTION Do not press the MANUAL AUTO button with wet hands or pointed objects otherwise an electric shock or malfunction may occur Starting Operation Press the MANUAL AUTO button on the operating control panel The operation can be set in the following setting Operating mode ...

Page 4: ...nside always consult authorized service personnel Be sure the intake grille is installed securely When cleaning the unit s body do not use water hotter than 40 C harsh abrasive cleansers or volatile agents like benzene or thinner If dirt is allowed to accumulate on the air filter air flow will be reduced lowering operating efficiency and increasing noise AB A 12 14 18 24 During periods of normal u...

Page 5: ...move the air filter 1 1 Pull out both sides and the center of the intake grille 2 Pull the air filters upward to remove them About 30 mm Side Panel Intake Grille Notch Arm Hook Arm Handle Intake Grille Base 2 Air Filter Bracket Cleaning 2 Cleaning the Air filter Remove dust with a vacuum cleaner or by washing After washing be sure to allow it to dry thoroughly in a shady place before reinstalling ...

Page 6: ... lights up and the TIMER indicator lamp orange flashes This is the standby state 3 Noise is heard In the following conditions there are sounds of water flowing from the indoor unit and the operation sound becomes loud These are the sounds of the flowing of refrigerant When operation starts When oil recovery operation finishes When automatic defrosting operation finishes During operation a slight s...

Page 7: ...performed The FILTER indicator lamp red is flashing very fast The wired remote controller or simple remote controller indicate Er when connected It has burning smell SPECIFICATIONS MODEL AB A12GATH AB A14GATH AB A18GATH AB A24GATH POWER SOURCE 230 V 50 Hz AVAILABLE VOLTAGE RANGE 198 to 264 V COOLING CAPACITY kW 3 6 4 5 5 6 7 1 HEATING CAPACITY kW 4 0 5 0 6 3 8 0 SOUND PRESSURE LEVEL HIGH dB A 36 4...

Page 8: ... reinigen Gießen Sie kein Wasser oder Reinigungslösungen direkt auf das Gerät und waschen Sie das Gerät nicht damit ab Setzen Sie die Klimaanlage keiner direkten Einwirkung von Wasser aus Betätigen Sie die Klimaanlage nicht mit feuchten Händen Installationsunterbau der Klimaanlage auf Beschädigung überprüfen Nur mit installierten Luftfiltern betreiben Trinken Sie nicht das abgelassene Wasser der K...

Page 9: ...AL AUTO Verwenden Sie den MANUAL AUTO Betrieb wenn die Fernbedienungs einheit verloren geht oder anderweitig nicht verfügbar ist VORSICHT Drücken Sie nicht mit nassen Händen oder spitzen Objekten auf die Taste MANUAL AUTO sonst kann es zu einem elektrischen Schlag oder zu Fehlfunktionen kommen Betrieb starten Drücken Sie die Taste MANUAL AUTO auf dem Bedie nungsfeld Der Betrieb kann mit der folgen...

Page 10: ...ts Um das Innere zu reinigen suchen Sie immer autorisiertes Fachpersonal auf Achten Sie darauf dass das Einlassgitter gut befestigt ist Verwenden Sie zum Reinigen des Gerätegehäuses kein Wasser das heißer als 40 C ist starke Scheuermittel oder flüchtige Mittel wie Benzin oder Lösemittel Wenn sich Schmutz am Luftfilter ansammelt ist der Luftstrom reduziert und die Betriebseffizienz sinkt und der Ge...

Page 11: ...ftfilters AB A 12 14 18 24 Entfernen Sie den Luftfilter 1 1 Ziehen Sie beide Seiten und das Mittelstück des Einlassgitters heraus 2 Ziehen Sie die Luftfilter nach oben um sie zu entfernen Etwa 30 mm Seitenteil Einlassgitter Kerbe Arm Haken Arm Griff Einlassgitter Gerä terahmen 2 Luftfilter Winkel Reinigung 2 Reinigung des Luftfilters Entfernen Sie den Staub mit einem Staubsauger oder durch Wa sche...

Page 12: ...tung durch geführt wird Die OPERATION Betrieb Anzei gelampe grün leuchtet auf und die TIMER Anzeigelampe orange blinkt Dies ist der Bereitschaftsstatus 3 Geräusche treten auf Bei den folgenden Bedingungen gibt es Geräusche von Wasser das aus dem Innengerät heraus fließt und das Betriebsgeräusch wird laut Dies sind Geräusche des fließenden Kältemittels Wenn der Betrieb startet Wenn die Ölrückführun...

Page 13: ... wenn die Fehlerbehebungsprüfungen ausgeführt wurden Die FILTER Anzeigeleuchte rot blinkt sehr schnell Die verkabelte Fernbedienung oder die einfache Fernbedienung zeigt Er an wenn angeschlossen Es riecht verbrannt SPEZIFIKATIONEN MODELL AB A12GATH AB A14GATH AB A18GATH AB A24GATH STROMQUELLE 230 V 50 Hz VERFÜGBARER SPANNUNGSBEREICH 198 bis 264 V KÜHLKAPAZITÄT kW 3 6 4 5 5 6 7 1 HEIZKAPAZITÄT kW 4...

Reviews: