background image

P/N9374379255-03

AIR CONDITIONER

DUCT TYPE

KEEP THIS MANUAL FOR FUTURE REFERENCE
DIESE ANLEITUNG BITTE SORGFÄLTIG AUFBEWAHREN
CONSERVEZ CE MODE D’EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT
GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO
CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO

KPATHΣTE TO EΓXEIPIΔIO ΓIA MEΛΛONTIKH ANAΦOPA

GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR

СОХРАНИТЕ НАСТОЯЩЕЕ РУКОВОДСТВО ДЛЯ БУДУЩИХ ССЫЛОК

BU KILAVUZU, DAHA SONRA BA

Ş

VURMAK ÜZERE SAKLAYIN

OPERATING MANUAL

BEDIENUNGSANLEITUNG

MODE D’EMPLOI

MANUAL DE FUNCIONAMIENTO

MANUALE DI ISTRUZIONI

ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ

MANUAL DE INSTRUÇÕES

РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

KULLANMA K

İ

TABI

English

Deutsc

h

F

rançais

Español

Italiano

EλληvIkά

P

o

rt

uguês

сс

кий

Türkçe

Summary of Contents for AIR CONDITIONER DUCT TYPE

Page 1: ...OGNI EVENTUALE FUTURO RIFERIMENTO KPATHΣTE TO EΓXEIPIΔIO ΓIA MEΛΛONTIKH ANAΦOPA GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR СОХРАНИТЕ НАСТОЯЩЕЕ РУКОВОДСТВО ДЛЯ БУДУЩИХ ССЫЛОК BU KILAVUZU DAHA SONRA BAŞVURMAK ÜZERE SAKLAYIN OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ KULLANMA...

Page 2: ...eriod of disuse in the winter turn the power switch on at least 12 hours before starting the unit l Do not drink the water drained from the air conditioner l Do not use in applications involving the storage of foods plants or animals precision equipment or art works l Do not apply any heavy pressure to radiator fins l Operate only with air filters installed l Do not block or cover the intake grill...

Page 3: ...IMER SET Button Vertical Airflow Direction and Swing Button 1 Horizontal Airflow Direction and Swing Button 2 MAINTENANCE FILTER RESET Button 3 Operation Lamp Timer and Clock Display Operation Mode Display Fan Speed Display Operation Lock Display Temperature Display Function Display Defrost Display Thermo Sensor Display Economy Display Vertical Swing Display 4 Filter Display 5 1 5 These functions ...

Page 4: ...und the selected day Press the SET TIME buttons to set the current time Press repeatedly to adjust the current time in 1 minute increments Press and hold to adjust the current time in 10 minute increments ex Monday PM11 00 Press again to end SU MO TU WE TH FR SA 1 3 5 Press the SET BACK button to switch between the 12 and 24 hour time displays 3 4 SU MO TU WE TH FR SA SU MO TU WE TH FR SA SET BACK...

Page 5: ...ation mode If DRY is selected the fan speed will be set to AUTO Press the SET TEMP buttons to set the room temperature Press the FAN button to set the fan speed Press the ECONOMY button to start or stop ECONOMY OPERA TION For details on the function refer to page 12 Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle To start stop operation To set the operation mo...

Page 6: ...an 2 seconds to se lect whether the room temperature is detected at the indoor unit remote sensor or the remote controller When the thermo sensor display appears the room temperature is detected at the remote controller NOTES This function is locked at the factory In order to detect the room temperature correctly consult authorized service personnel when using this function If this function is loc...

Page 7: ...p air conditioner operation The timer operates and air conditioner operation stops after the set time has passed The timer can be set up to 24 hours in advance ON timer See page 6 Use this timer function to start air conditioner operation The timer operates and air condition operation starts after the set time has passed The timer can be set up to 24 hours in advance WEEKLY timer See page 7 Use th...

Page 8: ...ng Up to two ON and OFF times can be set per day Press the DAY button to complete the time setting and return to the day of the week setting When the operating time is set the mark appears 5 Repeat steps 3 and 4 To complete the weekly timer settings press the TIMER SET button for 2 seconds or more l To delete the operating time If the TIMER DELETE button is pressed during steps 3 or 4 the operatin...

Page 9: ...to complete the DAY OFF setting 2 4 3 l To cancel Follow the same procedures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the next day during a next day setting the effective DAY OFF range will be set as shown below l Normal l Next day setting Setting day Preced...

Page 10: ...9 12 15 18 21 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 ex When setting all days together l Temperature setting Press the SET TEMP buttons to set the temperature The temperature setting range is the same as the range for the operation mode ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the TIMER SET button for 2 seconds or more to complete the temperature SET BACK timer settings 24 C 24 C...

Page 11: ...r air flow will be reduced lowering operating efficiency and increasing noise TROUBLESHOOTING Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle CAUTION WARNING In the event of a malfunction burning smell etc immediately stop operation turn off the electrical breaker and consult authorized service personnel Merely turning off the unit s power switch will not comp...

Page 12: ...ed afterward will stop and will be shown on the remote controller display of the stopped indoor units Heating mode and cooling mode or dry mode Heating mode and fan mode 14 l During QUIET operation the fan will operate at very low speed l In the monitor AUTO operation the fan will operate at very low speed Water is produced from the outdoor unit l During Heating operation water may be produced fro...

Page 13: ...he heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance l Heat pump air conditioners heat your entire room by recirculat...

Page 14: ... operate at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before beginning full operation l When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cyc...

Page 15: ...e units are used simultaneously for heating it is recommended that they be used in conjunction with other auxiliary space heaters as required l Seasonal and outdoor temperature conditions the struc ture of the rooms and the number of persons present may also result in differences of operating efficiency We recommend that you try various operating patterns in order to confirm the level of heating a...

Page 16: ...FUJITSU GENERAL LIMITED 1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan ...