CAPACITY COMPENSATION RATE FOR PIPE LENGTH
5.
AND HEIGHT DIFFERENCE
MODEL
: AO
G09LVCN, AO
G12LVCN
H
H
Height difference H
1 Indoor unit is higher than outdoor unit.
2 Indoor unit is lower than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
HEATING
Pipe length (m)
5
7.5
10
15
20
Height
difference H
(m)
Û
1
Indoor unit is
higher than
outdoor unit.
15
-
-
-
0.956
0.938
10
-
-
1.004
0.956
0.938
7.5
-
1.013
1.004
0.956
0.938
5
1.000
1.013
1.004
0.956
0.938
0
1.000
1.013
1.004
0.956
0.938
Û
2
Indoor unit is
lower than
outdoor unit
-5
0.995
1.008
0.999
0.951
0.933
-7.5
-
1.005
0.997
0.948
0.931
-10
-
-
0.994
0.946
0.929
-15
-
-
-
0.937
0.919
COOLING
Pipe length (m)
5
7.5
10
15
20
Height
difference H
(m)
Û
1
Indoor unit is
higher than
outdoor unit.
15
-
-
-
0.893
0.909
10
-
-
0.955
0.908
0.924
7.5
-
0.975
0.959
0.912
0.928
5
0.992
0.979
0.963
0.916
0.931
0
1.000
0.987
0.970
0.923
0.939
Û
2
Indoor unit is
lower than
outdoor unit
-5
1.000
0.987
0.970
0.923
0.939
-7.5
-
0.987
0.970
0.923
0.939
-10
-
-
0.970
0.923
0.939
-15
-
-
-
0.923
0.939
Summary of Contents for AG G09LVCB series
Page 2: ...1 INDOOR UNIT FLOOR TYPE AG G09LVCB AG G12LVCB AG G14LVCB DTR_AG004E_03 2013 01 21 ...
Page 33: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LVCN AO G12LVCN AO G14LVCN DTR_AO094E_02 2013 01 21 ...
Page 40: ... 02 06 OUTDOOR UNIT AO G09 14LVCN OUTDOOR UNIT AO G09 14LVCN MODEL AO G14LVCN ...
Page 47: ... 02 13 OUTDOOR UNIT AO G09 14LVCN OUTDOOR UNIT AO G09 14LVCN SOUND LEVEL CHECK POINT 88888 ...