3-3. Combination of external input and output
By combining the function setting of the indoor unit and rotary switch setting of the External input
and output PCB, you can select various combinations of functions.
Combination examples of external input and output are as follows:
Mode
Function
setting
External input
and output
PCB (Rotary
SW)
External input
Indoor unit
Input
External input and output PCB
Terminal
Input 1
Input 2
Signal type
0-1
60-00
1
Operation/Stop
Operation/Stop
Not available
Edge
Operation
Stop
Pulse
0-2
60-00
2
Operation/Stop
Forced
Thermostat OFF
Not available
Edge
1—8
60-01 to
60-08
3 - 9, A
(Setting prohibited)
9
60-09
B
Operation/Stop
Forced
Thermostat OFF
Not available
Edge
10
60-10
C
Operation/Stop
Forced
Thermostat OFF
Not available
Edge
11
60-11
D
Operation/Stop
Forced
Thermostat OFF
Not available
Edge
Mode
Function
setting
External input
and output
PCB (Rotary
SW)
External output
Indoor unit
Output
External input and output PCB
CN47
Output 1
Output 2
Output 3
0-1
60-00
1
Operation/Stop
Operation/Stop
Error status
Indoor unit fan
operation status
0-2
60-00
2
Operation/Stop
Error status
Indoor unit fan
operation status
External heater
output
1—8
60-01 to
60-08
3 - 9, A
(Setting prohibited)
9
60-09
B
Error status
Operation/Stop
Indoor unit fan
operation status
External heater
output
10
60-10
C
Indoor unit fan
operation status
Operation/Stop
Error status
External heater
output
11
60-11
D
External heater
output
Operation/Stop
Indoor unit fan
operation status
Error status
NOTE:
Input of Operation/Stop depends on the setting of function setting 46.
00: Operation/Stop mode 1 (R.C. enabled)
01: (Setting prohibited)
02: Forced stop
03: Operation/Stop mode 2 (R.C. disabled)
3-3. Combination of external input and output
- (05-13) -
3. External input and output for indoor unit
FIELD
WORKING
FIELD
WORKING
Summary of Contents for ABYG36KRTA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2020 11 16 SR_CH01_AB009EF_02 ...
Page 14: ...2 2 Outdoor unit 01 8 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 15: ...2 TECHNICAL DATA AND PARTS LIST 2020 11 16 SR_CH02_AB009EF_02 ...
Page 37: ...3 TROUBLESHOOTING 2020 07 21 SR_CH03_AB009EF_01 ...
Page 40: ......
Page 102: ...5 2 Outdoor unit 03 62 5 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 103: ...4 CONTROL AND FUNCTIONS 2020 07 21 SR_CH04_AB009EF_01 ...
Page 105: ...8 8 High temperature and high pressure release control 04 31 CONTENTS continued ...
Page 106: ......
Page 139: ...5 FILED WORKING 2020 07 21 SR_CH05_AB009EF_01 ...