SWING OPERATION

Begin air conditioner operation before performing this procedure

To select Vertical airflow SWING Operation

Press the AIR FLOW DIRECTION VERTICAL SWING button .

The SWING indicator lamp (VERTICAL SWING) (orange) will light.
In this mode, the UP/DOWN air direction flap will swing automatically to direct the
air flow both up and down.

To Stop Vertical airflow SWING Operation

Press the AIR FLOW DIRECTION VERTICAL SWING button
once again.

The SWING indicator lamp (VERTICAL SWING) will go out.
Airflow direction will return to the setting before swing was begun.

Example: 

When set to vertical swing.

SET

ENERGY

SAVE

TIME

ADJUST

TEST

RUN

 

ACL

SET

SWING

SWING

About Vertical Airflow Swing Operation

The range of swing is relative to the currently set airflow
direction.

Air direction range (See page 11, Fig. 8)

If the swing range is not as desired, use the remote con-
trol unit’s AIR FLOW DIRECTION VERTICAL SET button to
change the range of swing.

The SWING operation may stop temporarily when the air
conditioner’s fan is not operating, or when operating at
very low speeds.

During use of the Cooling and Dry modes, do not set the
air UP/DOWN direction flap, in the Heating range (

4

 to

5

) for long periods of time, since water vapor may con-

dense near the outlet port and drops of water may drip
from the air conditioner.

To select Horizontal Airflow SWING Operation

Press the AIR FLOW DIRECTION HORIZONTAL SWING button.

The SWING indicator lamp (HORIZONTAL SWING) (orange) will light.
In this mode, the RIGHT/LEFT air direction louvers will swing automatically to direct
the airflow both right and left.

To Stop Horizontal airflow SWING Operation

Press the AIR FLOW DIRECTION HORIZONTAL SWING button
once again.

The SWING indicator lamp (HORIZONTAL SWING) will go out.
Airflow direction will return to the setting before swing was begun.

Example: 

When set to horizontal swing.

Air flow direction set

1

2

3

4

5

Range of swing

1

 to 

3

1

 to 

3

2

 to 

4

3

 to 

5

1

 to 

5

 (All range)

SET

ENERGY

SAVE

TIME

ADJUST

TEST

RUN

 

ACL

SET

SWING

SWING

About Horizontal Airflow Swing Operation

The range of swing is relative to the currently set airflow
direction.

If the swing range is not as desired, use the remote con-
trol unit’s AIR FLOW DIRECTION HORIZONTAL SET but-
ton to change the range of swing.

The SWING operation may stop temporarily when the air
conditioner’s fan is not operating, or when operating at
very low speeds.

Air flow direction set

1

2

3

4

5

Range of swing

1

 to 

5

 (All range)

1

 to 

3

2

 to 

4

3

 to 

5

1

 to 

5

 (All range)

Air direction range (See page 11, Fig.9)

Summary of Contents for ABT30AG

Page 1: ...P N9361092013 02 OPERATING MANUAL Indoor Unit ABT30AG ABT30RG ABT36AG 3 ABT36RG 3 ABT45AG 3 ABT45RG 3 ABT54AG 3 ABT54RG 3 Outdoor Unit AOT30AB AOT30RB AOT36AC 3 AOT36RC 3 AOT45AC 3 AOT45RC 3 AOT54AB 3 AOT54RB 3 AIR CONDITIONER CEILING SUSPENSION TYPE ...

Page 2: ...the unit for extended periods Always turn off the electrical breaker whenever cleaning the air conditioner or chang ing the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow When restarting after a long period of disuse in the winter do Turn the power swi...

Page 3: ...AT COOL MODEL REVERSE CYCLE When the SLEEP timer button is pressed during Heating mode the air conditioner s thermostat setting is gradu ally lowered during the period of operation during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTRO...

Page 4: ...ERGY SAVE HEAT ON A AUTO HIGH MED LOW C F G H I J R U V W X Y S T K L M N O P D E Q CLOCK COOL AUTO Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle NAME OF PARTS Fig 5 Fig 1 Fig 4 Fig 3 Fig 6 Fig 7 This breaker is installed during the electrical installation SWING SWING TIMER OPERATION MANUAL AUTO 3 4 5 6 7 2 1 A A B 9 8 0 A A B Electrical Breaker Fig 2 ...

Page 5: ...will begin to flash simultaneously To stop the test operation mode either press the TEST RUN button once again or press the START STOP button to stop the air conditioner P ACL Button Q Remote Control Unit Display Fig 7 R Transmit Indicator S Clock Display T Operating Mode Display U Timer Mode Display V Fan Speed Display W Temperature Set Display X Timer Set Indicator Y Temperature Set Indicator Fi...

Page 6: ...again Remote Control Unit Holder For use as Handy Type CAUTION Take care to prevent infants from accidentally swallowing batteries When not using the remote control unit for an extended period remove the batteries to avoid possible leakage and damage to the unit If leaking battery fluid comes in contact with your skin eyes or mouth immedi ately wash with copious amounts of water and consult your p...

Page 7: ...rd value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when ...

Page 8: ...ons of the room and accordingly selects the proper operation mode When the air conditioner has adjusted your room s temperature to near the ther mostat setting it will begin monitor operation In the monitor operation mode the fan will operate at low speed If the room temperature subsequently changes the air conditioner will once again select the appropriate operation Heating Cool ing to adjust the...

Page 9: ... will alternately show OFF timer and ON timer then change to show the time setting for the operation to occur first The PROGRAM timer will begin operation If the ON timer has been selected to operate first the unit will stop operating at this point About five seconds later the entire display will reappear c c c d SLEEP TIMER SET TIME SET TEMP MASTER CONTROL FAN CONTROL TIMER ON SLEEP TIMER SET TIM...

Page 10: ...button Both the indoor unit s OPERATION indicator lamp red and the TIMER indicator lamp green will light To Change the Timer Settings Press the SLEEP button once again and set the time using the SET TIME buttons Set the time while the Timer Mode Display is flashing the flashing will continue for about five seconds button Press to advance the time button Press to reverse the time About five seconds...

Page 11: ...e riod Horizontal Air Direction Adjustment Press the AIR FLOW DIRECTION HORIZONTAL SET button Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 The remote control unit s display does not change Use the air direction adjustments within the ranges shown above Fig 9 DANGER Never place fingers or foreign objects in side the outlet port could cause personal injury...

Page 12: ...Heating range 4 to 5 for long periods of time since water vapor may con dense near the outlet port and drops of water may drip from the air conditioner To select Horizontal Airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button The SWING indicator lamp HORIZONTAL SWING orange will light In this mode the RIGHT LEFT air direction louvers will swing automatically to direct the a...

Page 13: ...eration The thermostat temperature setting increases by 1 C as soon as the ENERGY SAVE button is pressed and then increases by another 1 C after one hour has passed Afterwards energy consumption is saved by continuing to cool or dry at a thermostat temperature of 2 C more than that set ENERGY SAVE setting To Cancel the ENERGY SAVE Press the ENERGY SAVE button About the ENERGY SAVE MANUAL AUTO OPER...

Page 14: ...ll the air filters upward to remove them Remove the air filters by raising its handle while pulling it out towards you 2 Clean the air filters Remove the dust from the air filters by vacuuming or washing them After washing allow the air filters to dry thoroughly in an area protected from sunlight Air filter When used for extended periods the unit may accumulate dirt inside reducing its performance...

Page 15: ...emperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This result...

Page 16: ...eration and Performance Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we recom mend you use this air conditioner in conjunction with another kind of he...

Page 17: ... or less Outdoor temperature Indoor temperature Indoor humidity COOLING MODEL HEAT COOL MODEL Reverse Cycle Temperature and Humidity Range Cooling Dry Mode About 0 to 52 C About 21 to 52 C About 0 to 52 C About 18 C or more About 80 or less If the unit is used for long periods under high hu midity conditions conden sation may form on the surface of the indoor unit and drip onto the floor or other ...