background image

Note

 

-

 

The

 

phrase

 

"after

 

a

 

certain

 

amount

 

of

 

time

 

has

 

elapsed"

 

has

 

the

 

following

 

meaning:

(1)

 

The

 

15-minute

 

period

 

after

 

the

 

elapse

 

of

 

"24

 

days,

 

20

 

hours,

 

16

 

minutes,

 

and

 

23.648

 

seconds"

 

(25th

 

day)

 

from

 

physical

 

partition

 

(PPAR)

 

power-on

(2)

 

The

 

15-minute

 

period

 

after

 

the

 

elapse

 

of

 

above

 

time

 

(1)

 

and

 

the

 

elapse

 

of

 

a

 

multiple

 

of

 

time

 

of

 

"24

 

days,

 

20

 

hours,

 

31

 

minutes,

 

and

 

23.648

 

seconds"

 

(50th

 

day,

 

75th

 

day,

 

and

 

so

 

on)

WARNING:

 

Fail

 

to

 

attach:

 

8192

 

page

 

size

 

is

 

not

 

supported

 

by

 

the

 

controller.

A.5.1

Workaround

Apply

 

XCP

 

2330

 

or

 

later.

A.5.2

Corrective

 

Action

 

After

 

Occurrence

If

 

the

 

system

 

does

 

not

 

stop

 

at

 

the

 

ok

 

prompt,

 

apply

 

break

 

to

 

the

 

target

 

domain

 

to

 

stop

 

at

 

an

 

ok

 

prompt.

 

After

 

15

 

minutes

 

have

 

passed,

 

execute

 

the

 

boot

 

command

 

again.

A.6

Precaution

 

on

 

Installing

 

an

 

OS

 

on

 

the

 

Fujitsu

 

3.2

 

TB

 

Flash

 

Accelerator

 

Card

Installation

 

of

 

an

 

OS

 

on

 

the

 

Fujitsu

 

3.2

 

TB

 

Flash

 

Accelerator

 

Card

 

may

 

cause

 

the

 

following

 

message

 

to

 

be

 

output,

 

and

 

the

 

card

 

may

 

not

 

appear

 

as

 

an

 

OS

 

possible

 

installation

 

destination.

A.6.1

Workaround

To

 

install

 

an

 

OS

 

on

 

the

 

Fujitsu

 

3.2

 

TB

 

Flash

 

Accelerator

 

Card,

 

use

 

an

 

OS

 

installation

 

image

 

with

 

Oracle

 

Solaris

 

11.3

 

SRU

 

28.4

 

or

 

later

 

already

 

applied.

You

 

can

 

create

 

the

 

OS

 

installation

 

image

 

by

 

using

 

distro_const.

For

 

details

 

on

 

creating

 

a

 

custom

 

Oracle

 

Solaris

 

11

 

installation

 

image

 

for

 

Oracle

 

Solaris

 

11.3,

 

see

 

the

 

Creating

 

a

 

Custom

 

Oracle

 

Solaris

 

11.3

 

Installation

 

Image

.

A.6.2

Corrective

 

Action

 

After

 

Occurrence

None

Appendix

 

A

 

Precautions

 

and

 

Restrictions

C120-0067-02EN

A.6

 

Precaution

 

on

 

Installing

 

an

 

OS

 

on

 

the

 

Fujitsu

 

3.2

 

TB

 

Flash

 

Accelerator

 

Card

10

Summary of Contents for 7119601

Page 1: ...Fujitsu3 2 TBFl a sh Acc el e rat orCard User s Guide ForPr oduct Models7119601and7119603 Fujitsu 3 2 TB Flash Accelerator Card User s Guide For Product Models 7119601 and 7119603 C120 0067 02EN ...

Page 2: ...convenient location for quick reference Fujitsu makes every effort to prevent injury to users and bystanders as well as property damage Be sure to use the product in accordance with the instructions in this manual Product Notice This product is designed and manufactured for use in standard applications such as office work personal devices and general industrial use This product is not intended for...

Page 3: ...cuit different from that to which the receiver is connected Consult the dealer or an experienced radio television technician for help FCC WARNING Changes or modification not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ICES 003 Class B Notice Avis NMB 003 Classe B CAN ICES 3 B NMB 3 B Korean Class B Notice This equipment is hom...

Page 4: ...Related Manuals All documents for your server are available online at the following locations Sun Oracle software related documents Oracle Solaris etc http docs oracle com en Fujitsu documents Global site http www fujitsu com global products computing servers unix sparc downloads manuals Japanese site http www fujitsu com jp products computing servers unix sparc downloads manual Text Conventions A...

Page 5: ...y 26 2019 Whole manual added changed Added PM1725b to types of flash cards Changed card firmware version to GPNA5B3Q or GPJA0B3Q Appendix A added Added A 9 Precaution on the nvmeadm list s Command Warning Indications in the Text Warning markings are followed by warning messages A warning message is indented on the left and right sides to distinguish it from regular text Furthermore the lines immed...

Page 6: ...standers or damage to the product and or other property Only certified service engineers should perform replacement work The work must not be done by the customer under any circumstances Otherwise electric shock injury or fire may result Product Handling Precautions Maintenance Modifying or Recycling the Product Disposal or Recycling of Products at the End of Their Life Cycles Waste must be dispos...

Page 7: ...su 3 2 TB Flash Accelerator Card 7 Appendix A Precautions and Restrictions 9 A 1 Restrictions on Oracle VM Server for SPARC 9 A 2 Restrictions on PHP PPAR DR and Active Replacement 9 A 3 Disk Label Precaution 9 A 4 LBA Format Precaution 9 A 5 Precaution on OS Boot From FCode 9 A 5 1 Workaround 10 A 5 2 Corrective Action After Occurrence 10 A 6 Precaution on Installing an OS on the Fujitsu 3 2 TB F...

Page 8: ...ifications 13 B 3 Environmental Specifications 14 B 4 Electrical Specifications 14 B 5 Performance Specifications 14 B 6 Reliability Specifications 15 Appendix C Environmental Information 16 C 1 Taiwan RoHS Declarations 16 C 2 China RoHS Declarations 17 C 3 For Indian e waste Rules 17 Contents C120 0067 02EN vii ...

Page 9: ...Figure Table Contents Figure Contents Figure 1 1 Appearance of the Fujitsu 3 2 TB Flash Accelerator Card 2 Figure 1 2 Status Indicator LEDs 3 Contents C120 0067 02EN viii ...

Page 10: ...dicated by the Indicator LEDs 4 Table B 1 Product Specifications 13 Table B 2 Physical Specifications 13 Table B 3 Environmental Specifications 14 Table B 4 Electrical Specifications 14 Table B 5 Performance Specifications 14 Table B 6 Reliability Specifications 15 Table C 1 Taiwan RoHS Declarations 16 Table C 2 China RoHS Declarations 17 Contents C120 0067 02EN ix ...

Page 11: ...as a leaflet containing the URL for manuals Antistatic wrist strap 1 Chapter 1 Overview This chapter provides an overview of the Fujitsu 3 2 TB Flash Accelerator Card 1 1 Product and Model Names Table 1 1 lists the product and model names of the Fujitsu 3 2 TB Flash Accelerator Card 1 2 Components Table 1 2 lists the components of the Fujitsu 3 2 TB Flash Accelerator Card 1 3 Appearance Figure 1 1...

Page 12: ...arge capacity read cache for databases in combination with the Database Smart Flash Cache function of Oracle Database Enterprise Edition a large capacity read write cache for ZFS file systems The card can be used as the system boot drive Error monitoring and failure sign monitoring are possible with a standard tool of the OS The card is a suitable product for enterprises since a life of 5 DWPD x 5...

Page 13: ...ersion Oracle Solaris 11 3 SRU 11 3 28 4 0 or later Supported XCP version SPARC M12 1 XCP 3030 or later SPARC M12 2 and SPARC M12 2S XCP 3021 or later SPARC M10 XCP 2320 or later Card firmware version GPNA5B3Q or GPJA0B3Q 1 2 3 1 7 Status Indicator LEDs Figure 1 2 shows the indicator LEDs that indicate the status of the Fujitsu 3 2 TB Flash Accelerator Card Figure 1 2 Status Indicator LEDs Table 1...

Page 14: ...r of the following Linked up at PCIe x4 No PCIe link established 2 Service Action Required Amber On An error occurred Off The status is either of the following Operating normally Not powered on 3 Activity Signal ACT Green On Idle state Blinking I O access in progress Off The status is either of the following Inoperable state Not powered on Chapter 1 Overview C120 0067 02EN 1 7 Status Indicator LED...

Page 15: ...ls for the respective models of the SPARC M12 SPARC M10 and the PCI expansion unit Fujitsu SPARC M12 1 Service Manual Fujitsu SPARC M12 2 M12 2S Service Manual Fujitsu M10 1 SPARC M10 1 Service Manual Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10 SPARC M10 Service Manual Chapter 2 Fujitsu 3 2 TB Flash Accelerator Card ...

Page 16: ...ter 3 Fujitsu 3 2 TB Flash Accelerator Card Settings This chapter describes how to configure the Fujitsu 3 2 TB Flash Accelerator Card 3 1 Checking the Fujitsu 3 2 TB Flash Accelerator Card You can check the Fujitsu 3 2 TB Flash Accelerator Card in the same way as detecting a hard disk drive The command shown below is an example 3 2 Optimizing the Fujitsu 3 2 TB Flash Accelerator Card To obtain op...

Page 17: ...ite Commands 0x1027b4eb Controller Busy Time in Minutes 0x354 Number of Power Cycle 0x2 Number of Power On Hours 0x1c Number of Unsafe Shutdown 0x0 To align the first sector of the partition on a 4 KB boundary use the format e command to change the first sector to an appropriate value By setting the first sector value to 256 or a value for aligning on a 128 KB boundary you can ensure an alignment ...

Page 18: ...of Media Errors 0x0 Number of Error Info Log Entries 0x0 Chapter 3 Fujitsu 3 2 TB Flash Accelerator Card Settings C120 0067 02EN 3 3 Checking Various Information on the Fujitsu 3 2 TB Flash Accelerator Card 8 ...

Page 19: ...and physical partition dynamic reconfiguration PPAR DR functions cannot be used A 3 Disk Label Precaution Only the EFI disk label is supported because the size of the Fujitsu 3 2 TB Flash Accelerator Card is a disk volume exceeding 2 TB A 4 LBA Format Precaution The Fujitsu 3 2 TB Flash Accelerator Card supports only LBA formats with a block size of 512 bytes A 5 Precaution on OS Boot From FCode O...

Page 20: ...passed execute the boot command again A 6 Precaution on Installing an OS on the Fujitsu 3 2 TB Flash Accelerator Card Installation of an OS on the Fujitsu 3 2 TB Flash Accelerator Card may cause the following message to be output and the card may not appear as an OS possible installation destination A 6 1 Workaround To install an OS on the Fujitsu 3 2 TB Flash Accelerator Card use an OS installati...

Page 21: ...er Oracle Model Number A 7 Precaution on the nvmeadm namespace v Command Not 1 but rather 32 appears as the namespace ID A 8 Restriction on the n Option of the nvmeadm Command When specifying each namespace individually with the nvmeadm namespace online or other command specify and execute the a option namespace not the n option namespace ID The following example shows execution of nvmeadm online ...

Page 22: ...LS 00003GPNA5B3Q N A The actual PCIe IDs are as follows A 10 Restriction on probe nvme all The probe nvme all command cannot be used To confirm that the Fujitsu 3 2 TB Flash Accelerator Card is recognized on the OpenBoot PROM environment use the show devs command A 11 fwupdate Command Precaution The fwupdate list controller command does not display NVMe but rather SAS for Type The command shown be...

Page 23: ... Express Base Specification Rev 3 0 NVM Express Specification Rev 1 2 Enterprise SSD Form Factor Ver 1 0a Thermal throttling 80ºC or higher Throttling begins warning 87ºC or higher Full throttling 95ºC or higher Shutdown Encryption function Not supported Table B 2 Physical Specifications Item Specifications Width 69 9 mm Length 167 65 mm Height 18 71 mm Weight 310 g Appendix B Specifications B 1 P...

Page 24: ...r consumption Read 23 W Write 22 W Idle 8 W Table B 5 Performance Specifications Item Specifications Throughput performance Sequential Read 128 KB 6 200 MB s Sequential Write 128 KB 2 600 MB s I O access performance Random Read 4 KB 1 000 KIOPS Random Write 4 KB 170 KIOPS Random Read 8 KB 750 KIOPS Random Write 8 KB 105 KIOPS Latency Random Read Write 120 20 µs Sequential Read Write 110 30 µs Driv...

Page 25: ...9 98 84 Table B 6 Reliability Specifications Item Specifications Uncorrectable bit error rate 1 sector per 1017 bits read MTBF 2 000 000 hours Life 5 years Endurance 5 DWPD Data retention period 3 months Data protection at power outage Available B 6 Reliability Specifications Appendix B Specifications C120 0067 02EN B 6 Reliability Specifications 15 ...

Page 26: ...0 1 wt 及 超出0 01 wt 係指限用物質之百分比含量超出百分比含量基準值 Note 1 Exceeding 0 1 wt and exceeding 0 01 wt indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition 備考2 係指該項限用物質之百分比含量未超出百分比含量基準值 Note 2 indicates that the percentage content of the restricted substance does not exceed the percentage of reference value of presence 備考3 係指該項限用物質為排除項目 Not...

Page 27: ...levant threshold of the GB T26572 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出GB 26572规定的限量要求 Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the GB T26572 C 2 China RoHS Declarations C 3 For Indian e waste Rules This product does not contain 6 hazardous substances in accordance with article 16 1 in The e wast...

Page 28: ...Appendix C Environmental Information C120 0067 02EN C 3 For Indian e waste Rules 18 ...

Page 29: ......

Reviews: