![Fujitsu Siemens Computers AB* G45LRTA Service Instruction Download Page 8](http://html.mh-extra.com/html/fujitsu-siemens-computers/ab-g45lrta/ab-g45lrta_service-instruction_2344425008.webp)
01-05
START
Room temp.
Ts+2
°C
?
COOLING (AUTO:DRY)
OPERATION
HEATING OPERATION
YES
YES
NO
NO
NO
AUTO CHANGEOVER operation flow chart
T
S
:
Setting temperature
Room temp.
Ts -2
°C
?
Thermostat remains
in OFF state for 6 minutes or
longer?
System stops
or operation command other than
auto changeover operation?
NO
Thermostat remains
in OFF state for 6 minutes or
longer?
System stops
or operation command other than
auto changeover operation?
Middle zone
NO
Operation mode of
outdoor unit : Cooling or Dry?
YES
NO
Operation mode of outdoor unit
: Heating?
YES
NO
YES
Outdoor temperature
25
°C?
NO
YES
YES
NO
YES
YES