10

Installation

Attaching Duct Cover

1

Attach the duct cover

1) Set the duct cover on the cooker hood while

checking that the step screws are put into

the cutting parts of the duct cover.

2) Fix the duct cover using supplied 2 screws

(M4

×

8) from inside of the cooker hood.

Note

When attaching, be careful not to make any
scratches or damages.

In case that the duct cover is not high
enough, an optional duct cover is available

to extend the height of the duct cover.

When attaching the optional one, please

follow the instructions enclosed in it.

Duct cover

Screw

Step screw

Cutting part

2

Attach the slot filter

While holding the knob screw, set the rear of the slot

filter in the groove of the cooker hood, then lift up its

front and tighten the knob screw.

Tighten knob screw

Filter

Groove

Summary of Contents for NL-900V

Page 1: ... this manual in a convenient place for future reference To the sales shop installer After installing please give this manual to the user without fail Safety Precautions 2 3 Preparation 4 Name of Parts 4 Dimensions 5 Installation 6 Preparation and Check before Mounting 6 Cooker Hood Mounting 8 Attaching Duct Cover 10 Operation Check 11 Installation Manual Cooker Hood ...

Page 2: ...r emergency and severity Pay attention and strictly observe the instructions as they are critical for safety WARNING Alerts possible risk of death or serious injury if not observed CAUTION Alerts possible risk of injury or physical damage if not observed WARNING means prohibition It indicates actions if any that mustn t be done Left symbol Disassembly prohibited means forcible execution It indicat...

Page 3: ...esult in Assembly cautioned Contact prohibited Contact prohibited Be sure to wear gloves when care and maintenance Injury by the sharp edges or corners may result in Ensure that electric wiring is made safely according to the standard or regulations related Incorrect wiring may result in fire or electrical shock Don t touch the lamp cover or around it As it becomes high temperature burning may res...

Page 4: ...ame of Parts Preparation Duct cover Push button switch Rectifier panel Lamp cover Slot filter Lamp panel Power plug Fan Accessories Exhaust port 1 Soft tape 1 Washer head wood screw 5 1 45 8 Screw M4 8 2 Duct cover 1 ...

Page 5: ...iled From the bottom of the hood to the lower end of the filter Unit mm This cooker hood is designed to discharge upward Standard Mounting Height Mount the cooker hood at a place where more than 800mm between the surface of the gas range and the bottom of the cooker hood is cleared 800mm for optimum performance 453 453 600 640 410 800 or more than 800 optimum performance Unit mm ...

Page 6: ...om appliances burning gas or other fuels not applicable to appliances that only discharge the air back into the room 4 The minimum distance between the supporting surface for the cooking vessels on the hob and the lowest part of the cooker hood When the cooker hood is located above a gas appliance this distance shall be at least 80cm If the instructions for installation for the gas hob specify a g...

Page 7: ... port 2 Insert the exhaust port to the insertion slot on the top of the cooker hood and fix it using 2 screws The screws are supplied with attaching near the insertion slot Soft tape Note When attaching the exhaust port pay attention to its shutter opening direction If it s installed incorrectly it may cause bad discharge abnormal noise etc Fixing screw Insertion slot Shutter opening direction Uni...

Page 8: ...en push it up and backward to disengage from the hanging brackets 4 7 Removing slot filter While holding the slot filter by hand loosen the knob screw and open its front a little to take it out to the arrow direction Cooker Hood Mounting 1 Screw in washer head wood screws on the wall Referring to Dimensions on page 5 insert the washer head wood screws 5 1 45 into the mounting wall temporary fixing...

Page 9: ...ghten the screws Note Hook with inserting the exhaust port into the duct 4 Taping the duct joint Make the duct joint secure and air tight using non flammable tape such as aluminum tape etc not supplied Duct Aluminum tape 45mm or more 15mm or more Shutter axis Drilling tapping screw Exhaust port Drilling tapping screw usable range Note When fixing the exhaust port using a drilling tapping screw be ...

Page 10: ...e careful not to make any scratches or damages In case that the duct cover is not high enough an optional duct cover is available to extend the height of the duct cover When attaching the optional one please follow the instructions enclosed in it Duct cover Screw Step screw Cutting part 2 Attach the slot filter While holding the knob screw set the rear of the slot filter in the groove of the cooke...

Page 11: ... down 2 Make sure it is locked Rectifier panel 1 Hanging bracket Hooking bracket Note Make sure that the rectifier panel is locked securely It may be a cause of dropping if not locked firmly 1 Power supply Connect the power plug to the wall outlet 220V 230V 240V AC 2 Operation check 1 While operating the cooker hood by pushing the applicable control switches check the air flow or presence of abnor...

Page 12: ......

Reviews: