7
Installation
Note
Place the range hood on the sheet etc. as shown
in order not to scratch the floor.
3
Checking accessory parts
Take out the main unit and accessory parts (screws, exhaust port, etc.)
from the packing box, and check whether there is any shortage.
4
Removing rectifier panel
Loosen the mounting screws attaching the
rectifier panel, pull the rectifier panel upward
slightly to free the mounting screws from the
mounting guide holes and the body catches.
5
Removing slot filter
(FS-700: 1 filter, FS-890V/890R: 2 filters)
To remove the filters, for each filter, hold the knob,
push the filter downwards, and then pull forwards.
6
Removing hood cover
Remove 5 (M4×10) screws and 1 (M4×10
with washer) screw fixing the hood cover and
detach it.
Hood cover
M4
×
10
(with washer)
M4
×
10
Rectifier panel
Catch
Mounting screw
Catch
Slot filter