4
To place the plunger in the correct position
Remove the plunger cover.
1.
Make sure the plunger is oriented in the correct position. If not, lift the
2.
plunger from the two retaining pins. Rotate the plunger as follows:
To test standard fibers
To test BIF fibers
The side labeled “STANDARD”
is facing out and will be used
for aligning the tested fiber
The side labeled “BIF” is facing
out and will be used for aligning
the tested fiber
Replace the plunger and plunger cover.
3.
To test fibers
Select the splitter pigtail to be tested.
1.
Gently insert the fiber being tested into the fiber groove at the top of the
2.
OFI-FTTx head.
Pull down and hold the trigger to depress the fiber against the optical
3.
assembly.
Once the trigger is completely retracted, the OFI-FTTx will power up and
4.
light up the appropriate indicator.
If the fiber is carrying service, the [ONT Active] indicator will
•
illuminate showing the presence of service.
If no signal is present, the [Not Detected] indicator will
•
light up.